TEC Electronics FanControl-U2 User manual

www.tecel.ru
FanControl‑U2
Technical manual

Technical manual of FanControl-U2 module
2
Contents
1. Description of the module....................................................................................................2
2. Connection and conguration of the module ........................................................................3
Тable 1. Module connector pins designation ...................................................................3
Before installation .............................................................................................................4
Module programming ........................................................................................................4
Operation mode indication ................................................................................................4
Тable 2. LED indication......................................................................................................4
Intefacing module with a vehicle ......................................................................................5
Connection to CAN bus .....................................................................................................5
Module control ..................................................................................................................5
Programming sequence ....................................................................................................6
Тable 3. System setup .......................................................................................................6
Heater operation time .......................................................................................................7
Auxiliary heater mode .......................................................................................................7
W-BUS/Eberspacher protocol selection ...........................................................................7
Set heat-up temperature limit for aftermarket heater .....................................................7
3. Restoring factory settings ...................................................................................................9
Table 4. Technical data and operating conditions ...........................................................9
Table 5. Package contents ................................................................................................9
1. Description of the module
Module FanControl‑U2 is designed for operation in the following vehicles:
• Audi A3 (2013--), A6 (2011--), A7, A8 (2010--), Q5, Q7 (2011--), Q3, A5, Q7 (2015), ТТ (2015),
Audi Q5 (2017--), Audi A5 Coupe (2017--), Audi A5 Sportback (2017--), Audi А4 (2015--),
Audi A6 (2019--), A7 (2018--), A8 (2018--), Q8 (2018--)
• BMW 1 (F20), 3 (F30), 5 (F10), 6 (F13), 7 (F01, F02), X3 (F25), X1 (E84), 3 (E90), X5 (E70), X5
(F15), X6 (E71), 6 (Е63, Е64), X4 (F26), X6 (F16), X1 (F48); 7 (G11, G12); 5 (G30)
• Mini Cooper (2014--), Countryman (F60) 2017--
• Land Rover Range Rover Vogue (2013), Range Rover Vogue (2014--), Range Rover Sport
(2014--), Discovery 4, Discovery Sport (2015), Evoque (2011--), Freelander 2 (2013--)
• Mercedes-Benz 463 (2013--), 447, 222, 221, 218, 216, 212, 207, 205, 204, 176, 166, 156, 211,
219, 164(ML,GL), 251, 463, 203, 169, 639 (2003-2010), 639 (2010-2014), 906, 292 (GLE),
217, 253 (GLC) , 257
• Porsche Cayenne (2011--), Macan, Panamera (2009)
• Skoda Octavia 3; Skoda Octavia 2, Superb (2009--)
• Volkswagen Touareg (2011--), Touareg (2006-2010), Amarok, Multivan T5 (2003-2009),
Multivan T5 (2010--), Passat B6, Passat B7, Passat СС, Golf 5, Golf Plus, Jetta (2006--),
Caddy (2004--), Touaran, Tiguan, Golf 7, Crafter, Multivan T6 (2015), Multivan T6 (2016--),
VW Amarok (2017--), VW Caddy (2017--), VW Crafter (2017--), Porshe Cayenne (2018--),
Porshe Panamera (2017--), VW Touareg (2018--), VW Touareg (2018--)
• Seat Altea (2004--), Leon (2006--)
• Volvo XC 60 (2008-2010), XC 60 (2011--), XC 70 (2012--), XC 90 (2005-2014)
• Infinity QX 30 2016; QX 30 2017; QX 30 2018
You can nd connection manuals at www.tecel.ru/en/ or www.canbus-alarm.com.
The module allows implementing the following functions:
1. Activation of vehicle’s climatic system.
Figure 1. Package

Technical manual of FanControl-U2 module
3
2. Activation of vehicle’s factory heater.
3. A c tivation of heater and the climatic system for engine and interior warm-up using
vehicle’s factory button or factory remote control.
4. Control of Webasto Thermo Top C, Evo 5, Eberspächer D5WS heaters via digital bus.
5. Support of heat-assistance mode.
2. Connection and conguration of the module
Module pins designation is described in the Table 1 “Module connector pins designation”, and
connector pins enumeration — in Figure 2.
Figure 2. Connector pins enumeration. View from the harness side
Table 1. Module connector pins designation
Pin Wire color Type Designation Current
mA
1 Black Power Ground –
2Yellow/black
Yellow TP-Bus Digital bus for CheckControl –
3Grey/green LIN 1 Serial data bus –
4Grey/blue LIN 2 Serial data bus –
5Blue/yellow Digital bus
Special bus for controlling Webasto Thermo
Top C, Evo5, Eberspacher D5WS heaters Can
be used for control of aftermarket heaters
and, in specic cases, for factory heaters.
–
6-7 – – – –
8 Orange/green LED (+) –
9Blue Input (-) External input for module control (trigger
negative control) –
10 Green –
11 Pink/black Input (+) External input for module control (status
positive control) –
12 Orange/white –
13 Red Power +12 V –
14 Yellow/red Output (+) There is a positive signal during FanControl
operation 150 mA
15 Green/black Output (-) There is a negative signal during FanControl
operation 150 mA
16 Brown/red CAN 1 Vehicle CAN-H data bus –
17 Brown CAN 1 Vehicle CAN-L data bus –
18 Brown/yellow CAN 2 Vehicle CAN-H data bus –
19 Brown CAN 2 Vehicle CAN-L data bus –
20 Brown/green CAN 3 Vehicle CAN-H data bus –
21 Brown CAN 3 Vehicle CAN-L data bus –
22-24 – – – –
The Module shall be powered from one of vehicle’s wires with +12 V unswitched voltage.

Technical manual of FanControl-U2 module
4
Before installation
• Carefully read this technical description
• Check whether the module is compatible with the designated vehicle and make sure that the
required functions are supported by the module.
Module programming
The module is equipped with a micro-USB port which is used for connection of the module to a
PC via a micro-USB cable allowing to carry out programming and adjusting various settings of the
module by means of a special software which is called TECPROG (available for download at www.
tecel.ru/en/ or www.canbus-alarm.com). The software allows to program the module without ad-
ditional devices, quickly update the rmware, set a required vehicle model, activate the auxiliary
heater mode if desired, set up the module operation time, etc. The programming can also be carried
out either with a programming button – one of the vehicle’s interior buttons (the information on
which button is used on a particular vehicle is available at www. tecel.ru/en/ website), or with the
built-in button (gure 3).
Figure 3. FanControl-U2 module
Micro USB
Internal LED
Built-in
button
Operation mode indication
Indication is performed by means of the LED indicator. There are the following LED operation
modes: Table 2. LED indication
LED Reason
Constantly on Module is switched on
Off The module is switched off
x2 Low voltage shut-down
x4 at startup Heater error
Constant flashes Group-sugroup was not set
Constant group-subgroup
identication CAN was not identied
Indication when connected via W-BUS/Eberspächer protocol:
x1 pause x1 Switched off due to absence of communication or
according to the standard algorithm.
x1 pause x2 Low voltage shut-down of the heater
(registered by the heater)
x1 pause x3 Flame failure (only for Webasto)
x1 pause x4 Uknown error

Technical manual of FanControl-U2 module
5
Vehicle Identication
Identication is performed via TECPROG software or manually by using the built-in button.
Description of manual identication using of the built-in button:
CAN bus should not be connected prior to implementation of the identication procedure.
1. Power up the module. Wait for LED to star blinking.
2. Press the built-in button 4 times. The LED will flash 4 times (or will indicate programmed
group-subgroup) and will stay lit.
3. Enter a group number by the built-in button. After a short pause (1.5 second) the LED shall
indicate the entered number.
4. If group number consists of 2 digits – enter first digit, wait for indication, then enter second
digit and wait for indication
5. Enter a subgroup number. After a short pause (1.5 second) the LED shall indicate the entered
number. After a pause (about 4 seconds) the LED shall indicate the entered number (group
and subgroup) as a sequence of digits.
6. If a group and subgroup are entered correctly, press the built-in button one time, or two
times, if there was an error.
7. If the input data is correct (such model exists) the LED will blink 4 times and the unit will
reboot.
8. If the input data is wrong, the LED will light up for 15 seconds, expecting new group-subgroup.
If within 15 seconds there was no data entry – module will leave programming mode.
Connection to CAN bus
Connection types
There are two types of module connection to CAN bus:
• Parallel connection. It is used to control factory heaters. CAN1 pair is used for parallel
connection in all vehicles.
• Connection by cutting into CAN-bus. It is used to control factory heaters and the climatic
system.
In case of series connection CAN1 pair is connected from the vehicle’s side, and from the side
of a climatic system, CAN2 or CAN3 depending on vehicle model.
For description of FanControl-U2 module connection in specic vehicles and operational-
features with respect to different vehicles please visit www.tecel.ru/en/ website.
Module control
The module can be controlled:
• By the factory vehicle button (for information on which button is used for a particular
vehicle – see www.tecel.ru/en/ or www.canbus-alarm.com website)
• By the factory remote control
• By additionally installed devices through external input (GSM module, auxiliary car alarm etc.).
Module control by the factory vehicle button
Module activation/deactivation is performed by a long (not less than 2 seconds) pressing of a
certain factory button.
Module control by the vehicle factory remote control
Activation of the module is performed by triple pressing on the locking button not less than 15
seconds after the vehicle alarm is armed.
Deactivation of the module is performed by triple pressing on the unlocking button .
Pause between pressing on the button should be ~ 3 seconds.

Technical manual of FanControl-U2 module
6
Switch the module on/off with the external input
Status control *
12V
0V
Оn
Off
Input #11
FanControl
* To restart the module via input #11 it is necessary to switch off the “status” signal and then
activate it again.
Trigger control
12V
0V
Input #9
FanControl On
Off
Programming sequence
1. Choose required option in table 3. Then press PB amount of times corresponding to menu
code. LED will inform you about it’s state.
2. Change option state. To do so press PB required amount of times, required to change the
option value to the chosen one. Mind that the first value, goes after last value.
System will leave programming mode and save all changes after turning off the ignition or
after 15 seconds after last button press. LED will flash 4 times if settings are saved succesfully
or 1 time if there is an error during save.
Table 3. System setup
Menu Menu
code
Factory
default Note
Protocol
W-BUS/Eberspächer 61
Set automatically. Choose by hand if required.
1 – Automatic identication; 2 – Webasto;
3 – Eberspächer;
4 – Protocol control is forbidden;
5 – Factory Webasto heater alternative protocol
for VAG;
6 – Factory Webasto heater for RR Evoque
(2011-2013);
7 – Factory Eberspächer for RR Evoque (2011-
2013)/Sport (2014-2015);
8 – Factory Eberspächer for Toyota;
9 – Factory Eberspächer for RR Sport (2016)
The vehicle battery
voltage level for automaic
system shut down 11 91 — 10,5 V; … 9 — 11,3 V; ... 11 — 11,5 V
Heater operation time 10 31–10 min; 2–20 min; 3–30 min; … 12–120min
Supplementary (auxiliary)
heater mode 12 2
If outside temperature is lower 5°C — an
aftermarket heater will start automatically. If
outside temperature increases to12°C —
heater will turn off.
1 — on; 2 — off
Climate sytem control
algorithm 14 1
1 — standard;
2 — alternate algorithm №1*;
3 — alternate algorithm №2*;
4 — alternate algorithm №3*
Aftermarket heater
temperature limiter*15 1 1 — disabled; 2 — 71°C; 3 — 73°C; … 9 — 85°C
Climate control setup*20 1 1 — enabled; 2 — disabled
Climatic system settings 24 1
1 — Activation immediately after a heater
is turned on
2 — Delayed activation after a heater is turned on
3 — Activation by temperature
4 — Activation after a delay or by temperature
(depending on what comes rst)
5 — Climatic system inactive

Technical manual of FanControl-U2 module
7
Menu Menu
code
Factory
default Note
Delay prior to climatic
system activation 26 2 1 – 5 min; 2 – 10 min; 3 – 15 min; 4 — 20 min;
5 — 25 min; 6 — 30 min
Engine temperature to
acitvate the climate
system 28 21 — 30°C; 2 — 40°C; 3 — 50°C; 4 — 60°C;
5 — 70°C; 6 — 80°C;
Output №14 adjustment 30
1
1 — Heater operation (status).
The output generates a constant level signal
while a heater is running (If it is activated with
FanControl);
2 — Control of recirculating pump.
The output generates a constant level signal
while the engine heater is running and also
within 2 minutes after the heater is deactivated.
The signal is formed if the heater is activated
with FanControl.
3 — Interior ventilation running (status).
The output generates a constant level while
the ventilation is running (If it is activated with
FanControl).
4 — The ignition imitation.
The output generates a pulse signal during 5
sec. The output stops generating the signal
earlier if the FanControl module detects that
the ignition has been turned OFF or the heater
has shutdown.
5 — Auxiliary air heaters control.
The output generates a constant level signal
if the engine heater is turned ON. The output
stops generating the signal if the engine heater
is turned OFF. The output doesn’t generate any
signal if the auxiliary heater mode is activated.
6 — Cooling system loop-switching valve
control.
The output generates a constant level signal
after the engine heater is turned ON. The output
stops generating the signal in 20 minutes after
the engine heater has been turned off. If the
engine has been started before 20 minutes
expire – the signal will vanish in 5 minutes.
If the engine has been shut down before 5
minutes expire – the module will continue
generating the signal for 20 minutes.
Output №15 adjustment 32
Engine heater automatic
shutdown 44 2
1 — After the driver’s door is opened or the
brake pedal is pressed.
2 — After the ignition is turned ON.
* Used only in special cases. Check documentation to see which vehicles require these settings (www.tecel.ru/en/).
** Sensor is installed if there is no data in the CAN-bus.
Heater operation time
This option (table 3 option №10) allows to setup the module operation time (from 10 to 120
min. with 10 min. intervals). Programming is performed with the programming button (vehicle's
OEM button or the built-in one).
To be able to check or change the value of this option - switch the vehicle's ignition ON, no later
than in 10 seconds after turning the ignition ON press the programming button 10 times, wait
until the module indicates the option status by the corresponding number of LED flashes (from 1
to 12). To change the time interval, enter a desired value by pressing the programming button the
number of times required to advance from the current value to a desired one.

Technical manual of FanControl-U2 module
8
The default value is 3 (30 minutes). To exit the programming mode turn off the ignition or wait
for 30 seconds after the last press on the programming button was made.
The value of this option is ignored if the module is controlled via the status external control
input №11 (pink/black). The module remains activated until the signal is present at the
input, but for no longer than 120 minutes.
Auxiliary heater mode
In this mode an aftermarket self-contained heater operates according to the algorithms of an
OEM auxiliary engine heater: if the ambient temperature is below 5°С, the module will autmatically
switch into the auxiliary heating mode. If the ambient temperature rises above 12 °C, the heater
will switche off automatically.
To activate/deactivate the auxiliary heating mode switch the vehicle's ignition ON and press the
programming button 12 times (a standard button or the built-in one). The module shall indicate
the option №12 "Auxiliary heater mode" status (refer to the table 3 "System setup") as follows:
• 1 LED flash – the auxiliary heater mode is ON;
• 2 LED flashes – the auxiliary heater mode OFF (the default value).
W‑BUS/Eberspächer protocol selection
In most cases, the protocol is assigned automatically when you connect the system to a heater.
Manual selection of the protocol is required in exceptional cases. Programming is performed only
by the built-in button (see Figure 2). In order to select a protocol switche the ignition on, press the
programming button 6 times. The module shall inform about the item status by series of flashes:
• 1 signal – protocol is not set (factory settings).
• 2 signals – W-BUS.
• 3 signals – Eberspächer
• 4 signals – control is disabled.
Change item status by pressing the programming button as many times as it is required. The
module exits programming mode in 15 seconds after the last button-pressing. Upon successful
saving of settings, the LED would flash 4 times; 1 long flash means an error.
Set heat‑up temperature limit for aftermarket heater
This option is used with some vehicles in exceptional cases. You may nd recommendation
to use it in the corresponding manual (check www.tecel.ru/en/ or www.canbus-alarm for latest
manuals).
To change this option press programming button 15 times. Module will inform about its state
with series of LED flashes:
• 1 flash – off (factory default)
• 2 flashes – 71°C
• 3 flashes – 73°C
• 4 flashes – 75°C
• 5 flashes – 77°C
• 6 flashes – 79°C
• 7 flashes – 81°C
• 8 flashes – 83°C
• 9 flashes – 85°C.

Technical manual of FanControl-U2 module
9
TEC-63 400-19
Manufactured by TEC electronics
The product is manufactured according to Technical Specication
4372-006-78025716-10.
3. Restoring default settings
The following steps are required to reset to default settings:
1. Power the unit off.
2. Press the built-in button
3. Power on. While holding the button wait until the LED starts to flash.
4. Release the button and wait until the LED stops flashing.Technical data and operating
conditions Table 4. Package contents
Name Value
Supply voltage, V 9 ...15
Maximum current draw in operating mode, mA 200
Maximum current draw in standby mode, mA 2,5
Temperature, °С – 40 ... + 85
Maximum relative humidity, % 95
Table 5. Package contents
Name Number, pcs.
Central unit 1
Wire harness with connector 1
LED indicator 1
Enclosure ТЕС-0500 1
Technical description 1
Packaging 1
Product warranty period is 3 years from the date of purchase if installed according to the
instructions. Please contact your vendor if you wish to make a warranty claim.
Seller _____________________________ Date of purchase __________________________
Table of contents
Other TEC Electronics Control Unit manuals
Popular Control Unit manuals by other brands

Humminbird
Humminbird HICP200 Instructions for use

Allen-Bradley
Allen-Bradley ControlNet 1786-RPCD installation instructions

Union Switch & Signal
Union Switch & Signal GENISYS II Hardware installation

Neoway
Neoway Neo_M680 Hardware user's guide

Roger Technology
Roger Technology H70/104AC Instruction and warnings for the installer

GEM
GEM R693 Installation, operating and maintenance instructions