manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TECPEL
  6. •
  7. Measuring Instrument
  8. •
  9. TECPEL DPM 035 User manual

TECPEL DPM 035 User manual

Other TECPEL Measuring Instrument manuals

TECPEL DCM-043 User manual

TECPEL

TECPEL DCM-043 User manual

TECPEL DTM-322 User manual

TECPEL

TECPEL DTM-322 User manual

TECPEL pH-703 User manual

TECPEL

TECPEL pH-703 User manual

TECPEL PHS-864 User manual

TECPEL

TECPEL PHS-864 User manual

TECPEL DCM-039 User manual

TECPEL

TECPEL DCM-039 User manual

TECPEL LCR-612 User manual

TECPEL

TECPEL LCR-612 User manual

TECPEL CL-327A User manual

TECPEL

TECPEL CL-327A User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Tecpel True RMS AC/DC Powermeter DPM 035
When you need to find a meter that can handle just about any
measurement application, look no further than the DPM 035. This
clamp-style multimeter can handle your most demanding AC and DC
measurements, and has great featues like a large display for easy
readability and a unique "surge mode" for measuring in-rush current.
Features: Standard Accessories:
•3¾ digit display
with bargraph
•Soft Carrying Case
•13 measurement
functions, including
Crest Factor •Instruction Manual
•True RMS and
Average AC
Measurements up
to 1000A, 350kW,
and 600V
•Four AAA Batteries
•Data/Min/Max Hold
Function •Test Leads
•3 Year Warranty,
CE mark
General Specifications:
Display
0.8" digit LCD; 2/sec update rate
42 Segment Bargraph; 20/sec update rate
Max reading of 3500
Auto Power Off
Range Selection Auto / Manual
Operation Function
Min / Max / Data hold button
Zero (Relative) button
Surge mode for inrush current measurement
Crest Factor measurement mode
TRMS / Average AC selectable
Jaw Opening 57mm
Battery Life 500 hours
Overrange
Indication Most significant digit blinks
Low Battery
Indication Icon blinks
A
ccuracy Assurance
Temperature Range 18~28ºC, 75% R.H.
Operating
Temperature 0~50ºC, <70% R.H.
Storage
Temperature -20~60ºC, <80% R.H.
Power Supply Four AAA batteries
Dimension and
Weight 270(H) x 85(W) x 43(D)mm, 700g
Safety IEC-1010-1, UL-1244/UL-3111, CE mark
Accuracy Specifications:
Range Resolution Accuracy Remarks
Function- Active Power (V x A x CosØ)
3.5kW 1W
35kW 10W
350kW 100W ±(2.0%rdg+5dgt) 1200A overload
protection
Function- Apparent Power (V x A)
3.5kVAR 1VAR
35kVAR 10VAR
350kVAR 100VAR ±(2.0%rdg+5dgt) 1200A overload
protection
Function- Reactive Power (V x A x SinØ)
3.5kVAR 1VAR
35kVAR 10VAR
350kVAR 100VAR ±(2.0%rdg+5dgt) 1200A overload
protection
Function- Power Factor (CosØ)
3.5kW 1W
35kW 10W
350kW 100W ±(3.0%rdg+5dgt) 1200A overload
protection
Function- Crest Factor
up to 6:1 select range ±(3.0%rdg+2dgt) 1200A overload
protection
Function- ACA
35A 10mA
350A 100mA ±(1.0%rdg+5dgt)
1000A 1A ±(1.0%rdg+15dgt)
Surge Mode
±(3.0%rdg+5dgt)
Function- ACV
350V 100mV
600V 1V ±(1.0%rdg+5dgt) 45 - 400Hz
bandwidth
Function-Frequency
10Hz 0.01Hz
100Hz 0.1Hz
1KHz 1.0Hz
±(0.5%rdg+3dgt) 2V RMS Sensitivity
Function- DCA
35A 10mA
350A 100mA ±(1.0%rdg+5dgt)
1000A 1A ±(1.0%rdg+15dgt)
1200A overload
protection
Function- DCV
350V 100mV
600V 1V ±(1.0%rdg+5dgt) 10M Input
Impedance
Function-
35 0.01
350 0.1
3.5k 1
±(1.0%rdg+2dgt) 400VDC or
400VAC RMS
Overload Protection
Function-Continuity Test
Threshold <30