Storage
Temperature -20~60ºC, <80% R.H.
Power Supply Four AAA batteries
Dimension and
Weight 270(H) x 85(W) x 43(D)mm, 700g
Safety IEC-1010-1, UL-1244/UL-3111, CE mark
Accuracy Specifications:
Range Resolution Accuracy Remarks
Function- Active Power (V x A x CosØ)
3.5kW 1W
35kW 10W
350kW 100W ±(2.0%rdg+5dgt) 1200A overload
protection
Function- Apparent Power (V x A)
3.5kVAR 1VAR
35kVAR 10VAR
350kVAR 100VAR ±(2.0%rdg+5dgt) 1200A overload
protection
Function- Reactive Power (V x A x SinØ)
3.5kVAR 1VAR
35kVAR 10VAR
350kVAR 100VAR ±(2.0%rdg+5dgt) 1200A overload
protection
Function- Power Factor (CosØ)
3.5kW 1W
35kW 10W
350kW 100W ±(3.0%rdg+5dgt) 1200A overload
protection
Function- Crest Factor
up to 6:1 select range ±(3.0%rdg+2dgt) 1200A overload
protection
Function- ACA
35A 10mA
350A 100mA ±(1.0%rdg+5dgt)
1000A 1A ±(1.0%rdg+15dgt)
Surge Mode
±(3.0%rdg+5dgt)
Function- ACV
350V 100mV
600V 1V ±(1.0%rdg+5dgt) 45 - 400Hz
bandwidth