TABLE MAT: TIGHTENING
• If you feel the nylon mat needs to be tightened, pull the adjustment straps
on the back of the mat.
Assembly Instructions #IIL202 Pg. 4
Figure 9
STORING THE INVERSION TABLE
IMPORTANTNOTE: The F9000TM will not foldfor storage whilein Setting “C”
of the roller hinge. You must have the roller hinge set in either the “A” or “B”
setting to do so.
• Loosenthede-rattlerknob.
• Pull the height selector locking pin and slide the main shaft in all the way
to the ankle clamp assembly. Engage the pin in the storage setting.
• Rotate the table opposite from use until the table has turned 180 degrees
and rests against the cross bar on theA-frame.
• Thelegs of theA-framebase may then befolded together forcompact
storage.(Seefigure 9). WARNING: This operation may pinch fingers if
not done slowly and carefully.
For information about the Teeter Hang Ups®5-year warranty, or if you have any problems
assembling the equipment or questions about its use, please contact Customer Service at the
appropriate location below:
U.S.andforeignpatentsapply. Otherforeignpatentspending.
TeeterHangUps®isaregisteredtrademarkofSTLInternational,Inc.
andInversionInternational,Ltd.
Specificationssubjecttochangewithoutnotice.
©COPYRIGHT2004,InversionInternational,Inc.
InternationalLawProhibitsAnyCopying,11/04
* any modification to this device
will void the UL Classification
Classified as Medical
Equipment, part I in accordance
with UL 2601-1 and CAN/CSA
C22.2; General Requirements
for Safety in accordance with
Underwriters Laboratories, Inc.
TABLE MAT: REMOVING / CLEANING
• You may find it easier to remove the nylon mat while the table is in its
storageposition.
• Pull up on the plastic tension clips to loosen the adjustment straps.
• Release one corner at a time, then slide the mat off the frame.
• The mat should be washed in cold on gentle cycle. Replace the mat on
the table frame while still wet.
• To tighten the nylon mat, pull the adjustment straps on the back of the
mat.
ASSEMBLY
USA & Canada:
STLInternational, Inc.
9902162nd St.Ct. E., Puyallup, WA98375
TollFree(Phone)800-847-0143 (Fax) 800-847-0188
Local(Phone)253-840-5252 (Fax) 253-840-5757
International:
InversionInternational,Ltd.
POBox:AP59245,NewProvidenceIsland,Bahamas
(Phone) +1-242-362-1001 (Fax) +1-242-362-1002
European Distributor:
TeeterLtd.
CygnetHouse, Sydenham Road,CroydonSurrey, CR0 2EE,UnitedKingdom
(Phone)+44-20-8667-0060(Fax)+44-20-8680-3999
AuthorizedRepresentativeaccording to MDD93/42/EECMDSS
MurckhardstraBe1,30163Hannover, Germany