Service Manual
LCZ 837 - LP7 811 - LPM 809 - LV 831 - MLP 800
Service Manual: MSDW15050 - 3 -
At the same time, the buzzer will sound for 30 seconds and E1 will be shown.
E3 Heating exceeds pre-set time.
If the heating element has been working for 60 minutes but the water temperature
detected by NTC hasn’t reached desired value.
When E3 occurs, the drain pump will run until flowmeter keep motionless for 2
minutes and all the other components will be stopped immediately.
At the same time, the buzzer will sound for 30 seconds and the eE3 will be shown.
E4 Overflow
At any time, if overflow micro-switch act and keep for longer than 2 seconds, the E4
error will appear.
When E4 occurs, the drain pump will run until flowmeter keep motionless for 2
minutes and all the other components will be stopped immediately.
At the same time, the buzzer will sound for 30 seconds and error 4 will be shown.
Note: Priority level of E4 is the highest. E4 operation is valid after other error
operations. When E4 operation has done, all the others are invalid.
E6 Open-circuit failure of NTC Sensor
In test program, once open-circuit failure of NTC sensor is detected by controller, the
E6 will appear.
When E6 occurs, the drain pump will run until flowmeter keep motionless for 2
minutes and all the other components will be stopped immediately.
At the same time, the buzzer will sound for 30 seconds and error 6 will be shown.
E7 Short-circuit failure of NTC sensor
In test program, once short-circuit failure of NTC sensor is detected by controller, the
E7 will appear. When E7 occurs, the drain pump will run until flowmeter keep
motionless for 2 minutes and all the other components will be stopped immediately.
At the same time, the buzzer will sound for 30 seconds and error 7 will be shown.