Service Manual
DW7 57 FI –DW7 41 FI –LPI 759
Service Manual: MSDW15070 - 2 -
Open inlet valve and feeds with 3.6L (3.0 in
45cm. models)
Run washing pump for 2 mins.
Washing pump
and half load valve
Run washing pump for 1 min. If model is
equipped with half load valve, it would be
working during this step
Drain pump and
regeneration valve
Open regeneration valve and drain for 30 secs.
Buzz one sound, stop, and stand by.
4. Error codes
E1 Water filling exceeds pre-set time.
If the inlet valve has been opened for 4 minutes but the water quantity hasn’t reached
the desired value (measure by pulses).
When E1 occurs, the drain pump will run until flowmeter keep motionless for 2
minutes and all the other components will be stopped immediately.
At the same time, the buzzer will sound for 30 seconds and E1 will be shown.
E3 Heating exceeds pre-set time.
If the heating element has been working for 60 minutes but the water temperature
detected by NTC hasn’t reached desired value.
When E3 occurs, the drain pump will run until flowmeter keep motionless for 2
minutes and all the other components will be stopped immediately.
At the same time, the buzzer will sound for 30 seconds and the eE3 will be shown.
E4 Overflow
At any time, if overflow micro-switch act and keep for longer than 2 seconds, the E4
error will appear.
When E4 occurs, the drain pump will run until flowmeter keep motionless for 2
minutes and all the other components will be stopped immediately.