1
2
3
Ultrasonic LoRaWAN
Installation Guide
Thank you for purchasing the Tekelek Ultrasonic LoRaWAN waste bin
sensor which uses ultrasonic technology to measure the contents of your
waste bin and then communicates this data to a LoRaWAN network.
STEP 1: Activation
The Ultrasonic LoRaWAN waste bin sensor works in conjunction with a
LoRaWAN network and a connected platform and before activation must
first be registered with both. Access to the LoRaWAN backend server is
required to verify that the unit has correctly joined the network. See User
Manual for further details.
Ensure that the LoRaWAN™ network is within communication range of the
sensor. This should occur before the sensor is physically fitted onto the
Tank.
Place the sensor as close as possible to the point of installation,
press the button for 1 second to connect to the LoRaWAN
network and upload a status message.
The LED will stay illuminated as the sensor registers:
Red LED flashing = The sensor is registering & connecting for the first
time. (Sensor is shipped in dormant state).
Green LED flashing = The sensor is already registered. The
connection process will take between 20 & 40 seconds.
After the connection has completed, the LED will
flash on & off (to indicate whether the connection
was a success or failure).
LED Patterns
Press and hold the button for approximately 1 second, until the LED
turns green.
Wait approximately 10-20 seconds and observe if the LED flashes
green or red.
See the following for description of Green/Red LED flash codes.
LED Radio Signal Strength Flash Codes:
LED Pattern
Function
Green X 3 Flashes
Excellent signal strength
Green X 2 Flashes
Good signal strength
Green X 1 Flash
Adequate signal strength
Alternate Green/Red
Flash
Weak signal strength
Weak signal strength: Try 5 times and if this response is stable then
it’s deemed adequate. If the sensor shows some double red flashes
during this signal strength test - then an external antenna should be
tried. It may need to be elevated for best performance.
LED Error Flash Codes:
LED Pattern
Function
Red X 1 Flash
Authentication or LoRaWAN join
request fail
Red X 2 Flashes
No response from LoRaWAN network
Red X 3 Flashes
General Error. Please try again. If the
error persists, contact the supplier for
support.
Red X 5 Flashes
Maximum number of allowed button
presses exceeded (up to 6 button
presses per hour allowed).
STEP 2: Installation
The following outlines the Ultrasonic LoRaWAN waste bin sensor
mounting options.
The sensor is to be fitted on the underside (inside) of the top of
the waste bin.
The sensor must sit in a vertical position and be fitted such that
the sensor has a clear path to the tank contents. Position it so
that it is as close to the centre of the bin as possible and ensure
there are no internal obstructions that may interfere with the
ultrasonic signal.
Once a suitable position has been located, fix the sensor in place
by attaching the bracket to the waste bin using the bolt provided.
The antenna can be mounted on glass, metallic and plastic
surfaces.
The antenna RF cable is fed via the through hole mount base to
ensure no cable is visible when fixed and the rubber seal around
the base protects against water ingress.
The antenna is fixed via its 22mm length screw thread and can fit
onto panels of up to 13mm thickness.
4
5
6
Appendix 1: External Antenna
The external antenna should be elevated and clear of near obstacles for
best performance. The antenna should be mounted on a magnetic surface
(at least 15cm2 area) for best performance. The antenna requires self-
amalgamating tape to seal the antenna cable joint - Note: This cable joint,
while water resistant, should not be submerged in water.
Please see the Tekelek YouTube channel for video instruction.
Cut 300mm of ‘Tesa’ (provided) self-amalgamating tape.
After fitting in the required site location, connect the SMA connector
from the Antenna to that of the sensor.
Start wrapping the tape 70cm away from the SMA connection. The
tape needs to be kept in tension by stretching and the clear plastic
backing of the tape should be unwrapped as the installation
proceeds.
Keep the tape stretched while wrapping, over-lapping half the width
of the previous turn.
Continue to wrap the tape to a distance of 70cm on the other side of
the SMA connector. Then reverse the direction and continue to wrap
back along to the starting point. Note: the tape must be stretched
for best performance.
Excess cable can be looped and tie-wrapped.
A P-clip (shown in the picture below) is supplied to secure the
antenna cable and keep the sealed joint away from any standing
water.
For more information on the Tekelek Ultrasonic LoRaWAN waste bin
sensor please visit our website www.tekelek.ie where a link to our
YouTube page can also be found.
9-5983-02

Other TEKELEK Accessories manuals

TEKELEK LoRaWAN User manual

TEKELEK

TEKELEK LoRaWAN User manual

TEKELEK Ultrasonic LoRaWAN User manual

TEKELEK

TEKELEK Ultrasonic LoRaWAN User manual

TEKELEK LoRaWAN User manual

TEKELEK

TEKELEK LoRaWAN User manual

TEKELEK Ultrasonic 4G NB-IoT/CAT-M1 User manual

TEKELEK

TEKELEK Ultrasonic 4G NB-IoT/CAT-M1 User manual

TEKELEK Ultrasonic LoRaWAN User manual

TEKELEK

TEKELEK Ultrasonic LoRaWAN User manual

Popular Accessories manuals by other brands

PCB Piezotronics 132A32/AD Installation and operating manual

PCB Piezotronics

PCB Piezotronics 132A32/AD Installation and operating manual

Triangle Engineering Portable Coolers PC Series owner's manual

Triangle Engineering

Triangle Engineering Portable Coolers PC Series owner's manual

CombiSteel 7450.0315 user manual

CombiSteel

CombiSteel 7450.0315 user manual

Yekbee iPad Folio Keyboard Case user manual

Yekbee

Yekbee iPad Folio Keyboard Case user manual

aci DT2650 Installation & operation instructions

aci

aci DT2650 Installation & operation instructions

Daga Softy E Directions for use

Daga

Daga Softy E Directions for use

Sunx FX-100 SERIES Operation guide

Sunx

Sunx FX-100 SERIES Operation guide

xtpower MP-10400 quick start guide

xtpower

xtpower MP-10400 quick start guide

Fortinet FortiFone FON-D71 quick start guide

Fortinet

Fortinet FortiFone FON-D71 quick start guide

eTIGER SAC-03 user manual

eTIGER

eTIGER SAC-03 user manual

Smokin Crow EGO-CE4K user manual

Smokin Crow

Smokin Crow EGO-CE4K user manual

NCTE 2000 Series manual

NCTE

NCTE 2000 Series manual

Generix PROMNICO user manual

Generix

Generix PROMNICO user manual

La Crosse Technology TX141-Bv2 quick start guide

La Crosse Technology

La Crosse Technology TX141-Bv2 quick start guide

Belson MH5050 Use and care book

Belson

Belson MH5050 Use and care book

ECOWITT WH41 manual

ECOWITT

ECOWITT WH41 manual

KMC Controls NetSensor KMD-1261 Installation and operation guide

KMC Controls

KMC Controls NetSensor KMD-1261 Installation and operation guide

Hytronik HC419VRC/DH Installation and instruction manual

Hytronik

Hytronik HC419VRC/DH Installation and instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.