Funcon: TENS low frecuency pulse massage
Rated power: 1W
Power suply: Two AAA dry baeries
1.- Power / Mode buon: Long press for ON/OFF – Short press for MODE adjust.
2.- Intensity UP.
3.- Intensity DOWN.
4.- Floang Stainless Steel sheet.
5.- Baery cover.
6.- Electrode interface
7.- JT-500W with electrode sheet (Remember: only for “W” series)

JT-600/600W (Charging Model) Product Diagram
Funcon: TENS low frecuency pulse massage
Rated power: 1W
Power suply: Built-in 3.7V Lithium baery
1.- Power / Mode buon: Long press for ON/OFF – Short press for MODE adjust.
2.- Intensity UP.
3.- Intensity DOWN.
4.- Floang Stainless Steel sheet.
5 / 6.- Charging jack
7.- Electrode interface
8.- Charging cable
7.- JT-600W with electrode sheet (Remember: only for “W” series)

JT-700/700W (Rechargeable and Heang Model) Product
Diagram
Funcon: TENS low frecuency pulse massage and constant temperature hot compress.
Rated power: 1.5W
Power suply: Built-in 3.7V Lithium baery
1.- Power / Mode buon: Long press for ON/OFF – Short press for MODE adjust.
2.- Intensity UP.
3.- Intensity DOWN.
4.- Floang Stainless Steel sheet.
5 / 6.- Charging jack
7.- Electrode interface
8.- Charging cable
7.- JT-700W with electrode sheet (Remember: only for “W” series)

500 / 600 / 700 MODELS - Usage steps
1. Wet your neck, wear a massager
2. Long press the power buon for 3 seconds to turn on the machine
3. Short press the power buon to switch the mode
4. Press (+) key to adjust pulse strength enhancement
5. Press the (-) key to adjust the weakening of the pulse strength

500W / 600W / 700W MODELS - Usage steps
1. Disassemble the outer package and assemble the electrode sheet
2. Connect the cable
3. Wet your neck, wear a massager
4. Long press the power buon for 3 seconds to turn on the machine
5. Short press the power buon to switch the mode
6. Press (+) key to adjust pulse strength enhancement
7. Press the (-) key to adjust the weakening of the pulse strength

Tips
The product will automacally shut down aer running for 15 minutes. It is recommended to
use it no more than 30 minutes a day, and use it as needed every week. This product should be
stored in a venlated and dry place aer use. Do not use other heavy objects on the product.
Daily maintenence
When maintaining this product, please turn o the machine and clean the electrode pads with
wet paper towels. When it is parcularly dirty, use a lile medical alcohol (alcohol concentraon
75%) to wipe and disinfect. For daily maintenance, please use neutral detergent and so rag to
wipe. Do not use corrosive detergent. Do not immerse in water or rinse. During the cleaning
process, water or other liquids should be prevented from entering the body to avoid the risk of
short circuit and electric shock during use.
Method of operaon
Funcon operaon
1) Long press the power buon for 3 seconds to turn on the machine
2) Short press the power buon to switch the mode
3) Press the + key to adjust the pulse strength to increase
4) Press the - key to adjust the pulse strength to weaken
5) Automacally shut down aer 15 minutes
Convenience of "mode" key
Mode switching key: six modes can be selected by pressing the "start' key on the right handle.
The default startup seng is mode 1 (automac combinaon 1 mode), and the mode indicator
1 ashes. The intensity is the rst gear aer each mode conversion.
The six massage modes are:
Mode 1: automac combinaon 1
Mode 2: acupuncture
Mode 3: massage
Mode 4: nger pressure
Mode 5: kneading
Mode 6: hammer
Automac combinaon mode is recommended.
Use of "strengthen" key
Strength enhancement key: press the "enhancement" key on the le handle once each me to
increase the strength by one gear, with a total of 9 gears.

It is appropriate to massage with self acceptable strength. It is recommended to use a weak gear
for the rst me.
Use of "weaken" key
Strength weakening key: press the 'weakening' key on the le handle once each me to weaken
the strength by one gear, with a total of 9 gears. It is recommended to use for 10-20 minutes a
day
Charge the product or replace the baery
1. Rechargeable product: When the host is short of power, the colorful lights are dimmed or
cannot be turned on, use the special charging cable to plug into the host and the other end into
the mobile phone charger (the output is 5V-1A / 2A), and the light will be on when charging , Full
of exnguished.
2. Baery type products: When the host is short of power, the colorful lights will dim or cannot
be turned on. Please replace the dry baeries of the same model.
TROUBLESHOOTING
If you encounter problems when using the product, please refer to the following ps and
soluons.
- If the product is sll in a fault state or cannot be used, please turn o the power.
- The user should not dismantle or repair the product by himself.
- The product damage caused by the disassembly or repair will invalidate the product warranty,
and the company will not bear any consequences caused by this situaon.
* Unable to start
The baery is low. Please conrm whether the switch buon of the host product has been
pressed
* Cannot charge or no charge lamp display
Please check whether the USB cable and the host and mobile phone power adapter are
connected.
* Normal display but no feeling
Does the electrode pad directly contact the skin? Adjust the posion so that it is close to the
skin.
Are there any items such as hair or clothing, accessories, etc. between the electrode pad and the
skin? Remove or remove the items.
Is the intensity level 1st gear? Adjust to increase the massage intensity.
* Tingling
Is the electrode pad contacng the skin on the neck? You need to adjust the posion to make it
close to the skin.
Is the massage too long? It is recommended to press 15 minutes at a me and twice a day.

Is the massage intensity too strong? Adjust the intensity to a small amount.
Is the skin allergic to electrode pads? Paents with severe allergies need desensizaon
treatment.
Cold climate, dry skin? Use aer moistening your skin with a wet towel.
Is there a wound on the skin surface? Do not put the electrode pads on the wound to massage.
* Smulaon is weak
Does the massager electrode pad say that the neck skin is ght? Adjust the posion so that it is
close to the skin and adjust the appropriate strength.
Is the electrode dirty or oily? Clean the electrode surface.
Is the baery low? If it is low, charge it.
The intensity of the massage posion is too small? Adjust to increase the intensity of the
massage.
PRECAUTIONS
Danger
Please be careful not to use the following medical electronic devices together
1. Cardiac pacemakers and other implantable medical electronic devices
2. Life-sustaining medical electronic devices such as arcial hearts and lungs
3. Electrocardiogram - like medical electronic equipment; These medical electronic devices will
cause misoperaon and may be life—threatening;
4. Gas staons, high—dust vehicles, gas and other ammable and explosive places are
prohibited.
Caveat
If the paent uses both high-frequency surgical equipment and this product on their body, the
electrode pads of the product may cause burns or damage the product.
If this product is used near short wave or microwave treatment equipment, the output of the
product may be unstable.
Electrode pads during massage should avoid contact with wounds and scars. During massage,
the electrode pads should not be placed near the chest and heart, otherwise it will increase the
risk of heart brillaon.
The product is recommended for one user. For cross-user use, please clean the electrode pads
on the product before use.
When using the product, the electrode pad should be ghtly aached to the skin and evenly
contacted. The electrode pad of this product has a heat generang funcon. When using the hot

compress funcon in the same part for a long me (more than 15 minutes), it may cause low
temperature burns. If you feel unwell during or aer use, stop using it and consult a doctor. This
product contains lithium baeries or dry baeries. Please do not disassemble, modify, immerse
the product in water or throw it into re, otherwise it may cause product damage and explosion
In the following cases, please consult your doctor before use.
Otherwise, an accident or physical discomfort may occur.
1. Paents who are receiving medical treatment and feel abnormal.
2. Paents with abnormal heart and brain nerves
3. Paents whose body temperature exceeds 38 degrees (fever period).
4. Paents with infecous diseases.
5. Paents with impaired skin percepon or abnormal skin.
6. Paents taking medicaon.
7. Paents with abnormal blood pressure.
8. Paents who cannot express their wishes freely.
9. Paents with sensory disturbances due to diabetes due to high endless circulaon disorder.
10. Paents with skin allergy to stainless steel electrodes.
The following situaons are prohibited:
1. Malignant tumor constuon
2. Paents with bleeding tendency
3. Pregnant women and parturients
4. Acute constuonal inammaon constuon
5. Heart pacemaker users
6. Paents with metal implants
7. Near the human heart
Do not use near the heart, above the neck, head, mouth, genitals, or skin disorders and cannot
treat the soles of both feet. In addion, do not press on the internal organs during use.
Otherwise, an accident or physical discomfort may occur.
Do not write about other medical devices or use more than two of this product together,
otherwise it may cause nausea or physical discomfort.
Do not use for massage purposes other than those described in the instrucon manual,
otherwise an accident or malfuncon may occur.
Do not use electrode pads that are notched or damaged on the surface, otherwise accidents or
malfuncons may occur.

Do not disassemble, repair and modify this product without authorizaon, otherwise it may
cause malfuncon or electric shock. note If you feel unwell due to abnormality of this product,
please stop using it immediately.
If your body or skin feels strange, please consult your doctor and act accordingly. During the
massage, if you want to move the electrode pads or other people, be sure to cut o the power
before moving, otherwise you may receive a strong electric shock.
Do not bring electronic devices for treatment. Otherwise, the electronic device may be misused
for example, the electronic watch is always messy). When an abnormal situaon that cannot be
operated occurs, immediately cut o the power and remove it, otherwise high temperature or
short circuit may occur and an accident may occur. At the same me, contact aer—sales
customer service consultaon.
Do not plug or unplug the USB charging cable with wet hands, otherwise it may result in electric
shock or accident.
Do not use it for children or people without the ability to express consciousness, otherwise it
may cause accidents or bowing.
Do not use it in places with high humidity, such as bathrooms, or use the product while taking a
shower. Otherwise, you may receive a strong electric shock and damage the product.
Do not use it at bedme, otherwise the product may malfuncon, and the electrode pad may be
moved to other parts and cause physical discomfort.
Do not use when driving a car, otherwise it may cause physical discomfort due to excessive
smulaon, resulng in an accident.
Do not sck the electrode pads on the aected area for a long me, otherwise it may cause skin
diseases When massaging, do not allow the metal parts of skin, necklaces, and other objects to
contact the electrode pads, otherwise you may receive a strong electric shock.
Do not use the some part for a long me (more than 30 minutes), otherwise it may cause muscle
fague at the massaged part Please wear this product correctly for the neck and laurel parts,
symmetrical le and right, otherwise accidents or bowing may occur. When unplugging the USB
charging cable from the main body, do not pull the wire, but pull it out by holding the wire plug,
otherwise it may cause electric shock or damage the product. The electrode pad of the product
has a surface heang funcon. Users who are not sensive to heat or are easily allergic to heat
should consult a doctor. When the product works for a long me, there will be heat on the
surface, which is normal. When the product is not used for a long me (more than 3 months),
please charge the product every three months. When the baery is not used for a long me,
please remove the baery to avoid damage to the baery and aecng the host parts.
Caveat
Please conrm that the host buons work normally before use. When the baery is used for the
rst me, or aer the product is le for a long me, please recharge or replace the baery
according to the instrucon manual to ensure that it can work normally.
When discarding this product, please deal with it in accordance with the relevant environmental
protecon regulaons of the city, otherwise it may cause environmental polluon. It is
recommended for people aged 16 and above.

Do not use or store this product in the following places: Places with direct light; places with high
temperature and humidity; places with water; places with more dust exnguishment; places
prone to vibraon and shock near reworks; places with strong electromagnec elds
REMINDER FOR RECYCLING
In order to protect the environment, aer the product or its parts are scrapped, you as a
consumer are responsible for separang their household waste and sending it to a qualied
recycling site, which will be disassembled, recycled, and reused according to relevant naonal
regulaons.
This manual suits for next models
5
Table of contents
Other tekkiwear Massager manuals