Mode button
Auto, Heat, Cool, Off
Fan button
Switch between Auto or On
User Interface7.
For a full list of settings and operational details, please refer to the thermostat Installation and Operation Manual
(D540) included with compatible tekmarNet®controls or download the brochure from www.tekmarcontrols.com
• Press and hold down both the and buttons for 2 seconds to change from one step to the next.
• Release both buttons once the step has been reached.
• Press the or the button to change the setting, if available.
• Press and hold down both the and buttons for 2 seconds to go to the next step, OR
• After 10 seconds of no button activity, the display goes back to normal operation.
Press
+
Together
The following settings are essential to the successful operation of the system.
Important
Note: Set switch setting #4 and tekmarNet
®
system control to Unlock to change Access level to Installer. Return to Lock
setting once installation has been completed.
Display Range Access Description Set to
°F or °C
Default = °F
Installer
User
TEMPERATURE UNITS
Press the or the button to change from °F to
°C and vice versa.
0, 1, 2, 3
Default = 1 Installer
FAN MODE
Select how the fan should operate together with heating
and cooling.
0 = Manual operation only
1 = Operate fan with cooling only
2 = Operate fan with heating and cooling
3 = Operate fan with heating only
Hyd
(Hydronic)
or Oth
(Other)
Default =
Hydronic
Installer
HEATING TERMINAL TYPE
Select if the heating for this zone is hydronic or non-
hydronic (other).
Available when:
A reset control is present on the tekmarNet®
system.
•
OFF, dLy
(delay), On
Default = On Installer
HEATING SUPPLY PUMP
Select how the system supply pump should operate:
On = system pump on during a call for heat.
Delay = system pump delayed 3 minutes for thermal
motor (wax actuator) zone valves to open.
Off = system pump not turned on during a call for heat.
Use when a manifold uses a Zone Group Pump.
Available when:
A reset control is present on the tekmarNet®system
AND Heating terminal type is set to Hydronic.
•
Critical Settings8.