Page 2
TekTone Sales Support Bulletin – No. 2 2
6.Double clickthe“Default Settings” folder icon (thefollowingwill appear).Information enteredhere will be
usedas thedefault entryfor all zone programmingentries. This information can bechangedfor any
zone entries later in theprogrammingprocess.
Untitled
Default Settings
Location
Priority1
Priority2
Priority3
Reset
Add Another Zone
7.ClickonthePriority1folder (Priority1=high)
Location =RoomNo. (for example)
Pager type =Alphanumeric
Beep type =C
Pager ID = pager cap code(calculates as 10000 + [pager #x8]),i.e. pager #400 = 13200
Messagebox=high prioritycall label (ex.Smoke Detector)
8.ClickonthePriority2folder (Priority2=medium)
Location =RoomNo. (This information is automaticallyenteredfromprevious entryin priority1)
Pager type =Alphanumeric
Beep type =B
Pager ID = pager cap code(calculates as 10000 + [pager #x8]),i.e. pager #400 = 13200
Messagebox=mediumprioritycall label (ex.Bath/Emergency)
9.ClickonthePriority3folder (Priority3=low)
Location =RoomNo. (This information is automaticallyenteredfromprevious entryin priority1)
Pager type =Alphanumeric
Beep type =A
Pager ID = pager cap code(calculates as 10000 + [pager #x8]),i.e. pager #400 = 13200
Messagebox=lowprioritycall label (ex.Routine)
10.Double-clickDefault SettingFolder to collapse thedirectorytree. Single-clickonAdd Another Zone,click
in textboxon theright,type thenumber rangeofzones to add (ex.1-20 creates zones 1through 20)
11.Single-clickonZone 1andenter first roomnumber in Location Boxon theright,after thedefault
labeling.Then selecteach ofthesubsequent zones andenter therespectiveroomnumbers. NOTE: The
architectural roomnumbers must correspondwiththephysical point-wire connections to thevoltage
interface’s terminal blocks. Zone 1in theprogrammingsetup = CH1 in thevoltage interface’s terminal
blocks.
12.Savefile by pressingCTRL-Aor selectFile |Saveas.Then enter a file nameandclickOK.
13.ProgramtheNC375 unit by pressingCTRL-Wor selectDevice|DeviceWrite. ClickOK.
14.Verify that theprogrammingmatches the unit:Press CTRL-Vor selectDevice|DeviceVerify.ClickOK.
15. Power downtheNC375 unit,disconnectthe serial cable fromthecomputer andconnecttotheNC366A
transmitter. Power up theNC375,NC366A, andtest by placingcalls fromeach room.