Teleco Simple Panel User manual

Teleco Simple Panel –
Set up guide
Wired safety edge
system

Right Hand motor wiring Brown 5 –Blue 6 –Black 7
Left Hand motor wiring Black 5 –Blue 6 –Brown 7
Wiring the motor into the control panel
Please ensure you follow each step before moving onto the next page
Please ensure when fixing the control panel to the wall you use the template provided to prevent any damage during installation, failure to do so may
invalidate your warranty.

Remove the resistor from terminals 16 & 17
Wire your spiral cable into the control panel Brown 16, Green 17, White 18
Wired Safety Edge Set Up
Your spiral cables comes pre-wired into the junction box so all you need to do
is wire the opposite end into the control panel.
If correctly wired and no fault exists the green LED light will be permanently ON inside the junction box
Please ensure you follow each step before moving onto the next page

Motor limits and set up
The control panel has to detect the TOP limit before normal operation and each time
after mains power is turned off and then on again.
It is important to set the motor limits first using either a test lead or the two buttons
inside the control panel and the limit adjustment screws.
Using either a test lead or the P1 (down) & P2 (up) hold -to -run buttons inside the control panel:
1. Run the motor in the down direction until it stops. At this point attach the curtain via the straps
provided unless already attached.
2. Fine adjust the bottom limit.
3. Run the motor up to the top leaving only the bottom piece of the door within the tracks.
4. Fine adjust top limit.
If the door runs higher than needed reduce the travel via the below steps:
To increase the travel turn the limit screw towards the ‘+’ direction.
To reduce the am ount the door travels turn the limit to the ’-’ direction.
Tip:
Right hand motor -RED = Down limit -WHITE = Up limit
Left hand motor -WHITE = Down limit -RED = Up limit
P1 P2
To Exit Hold -to -run set up mode press the P1 & P2 buttons
together for 3 times on the 3rd press hold until it beeps and
both L1 & L2 lights go out. The panel is now in Day to Day
running mode.
Limit
Adjuster
Limit
Adjuster
Arrows
indicate
Direction
of rotation
for the
tube motor
Hold -to -run set up mode
If the door is moving in the wrong direction:
a. STOP the manoeuvre
b. Switch off the control unit
c. Swap BLACK & BROWN motor wires over –terminals 5 & 7
d. Power up the board again –go back to bullet point 1
Please ensure you follow each step before moving onto the next page

Programming a transmitter to 2 channel
One button to Open & One button to Close
Please note: you have 8 seconds to do this step, if you get a series of beeps you will
need to start the transmitter programming again.
1. Press P1 & P2 together & hold for a few seconds until L1 & L2 lights flash rapidly –you will
hear a long beep.
2. Release both buttons then a quick press & release P2 & then press & hold P2 (circled) & at
the same time press the top button on your transmitter.
3. The long beep will change to a rapid beep –this means the button is now programmed.
4. Release both buttons & test your transmitter.
5. Please repeat this process for all transmitters.
Please ensure you follow each step before moving onto the next page

Programming a transmitter to 1 channel -Both doors on one transmitter
(2 door installation)
Please note: you have 8 seconds to do this step, if you get a series of beeps you will
need to start the transmitter programming again.
1. Press P1 & P2 together & hold for a few seconds until L1 & L2 lights flash rapidly –you will hear a
long beep.
2. Press & hold the P2 (circled) button & at the same time press the selected button on your
transmitter.
3. The long beep will change to a rapid beep –this means the button is now programmed.
4. Release both buttons & test your transmitter.
5. The button chosen will operate as open/stop/close/stop.
6. Please repeat this process if multiple doors are to programmed into this transmitter.
Please ensure you follow each step before moving onto the next page

Deleting all transmitters from the control
panel
1. Switch the panel off & back on again –within
5 seconds press P1 & P2 together 3 times.
2. Press the white P1 button (circled) in the
control panel 5 times and hold on the 5th
press –you will hear rapid beeps from the
control panel.
3. Keep hold of the P1 button until you hear a
long beep –this will take approx. 10 seconds.
4. When you hear the long beep take your
finger off the button and test to make sure
everything is deleted.
Please ensure you follow each step before moving onto the next page

If the door reopens having hit the floor the safety edge exclusion should be set to ‘turn off’ the edge 50mm before it hits the floor.
1. Power on & within 30 seconds L1 & L2 lights are on for 5 Seconds & then L1 & L2 lights turn off.
2. Within 5 seconds of step 1 press & hold P1 & P2 once for 1 second –L1 & L2 lights will flash
rapidly.
3. Press P2 button 10 times and keep it pressed on the 10th press for 5 seconds –The buzzer emits 3
beeps
4. Open the door completely by means of a memorized transmitter. The buzzer emits a long beep
when the upper limit switch is reached.
5. Put under the door, an object not more than 5cm high. A small piece of wood should be
sufficient.
6. Close the door (in hold-to-run mode) keeping your finger pressed on the transmitter with no
interruption. The door will stop at the obstacle and the control unit will make a long beep.
7. Open the door completely and remove the object.
8. Close the door to verify the correct application of the procedure.
Safety Edge Exclusion in the last 5cm of travel
Please ensure you follow each step before moving onto the next page

If the door beeps 5 times instead of closing, dip switch 2 may
be in the wrong position.
To alter the dip switches this must be done within 30 seconds of powering on the control panel
Dip switch positions
The dips switches are pre set and should not need to be touched. (as shown)
1 -ON
2 -OFF
Please ensure you follow each step before moving onto the next page

Table of contents
Popular Control Panel manuals by other brands

American Lighting
American Lighting TRULUX SRF-4Z-3P installation instructions

arowana
arowana Dynadose A75 operating manual

Incite Fire
Incite Fire Sigma CP AFP-2516 manual

U-Prox
U-Prox MP LTE quick start guide

Eaton
Eaton DF6000 Application guide

Beijer Electronics
Beijer Electronics M70 installation manual

Nittan
Nittan 1PM3-nLA Operating instructions manual

Beckhoff
Beckhoff CP6608 Installation and operating instructions

S&S Northern
S&S Northern Merlin CT1650+ user guide

DMP Electronics
DMP Electronics XR150FC Series System user's guide

RIB
RIB MINI TS manual

Trox Technik
Trox Technik EASYLAB Assembly and operating instructions