Teledyne PROTEGE ZM User manual

087-0047, Rev. G/December 2019
PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
USER GUIDE
WARNING: ALL INDIVIDUALS WHO HAVE OR WILL HAVE RESPONSIBILITY FOR
USING, MAINTAINING, OR SERVICING THIS PRODUCT, MUST READ
THIS ENTIRE MANUAL CAREFULLY. FAILURE TO USE THIS EQUIP-
MENT PROPERLY COULD RESULT IN SERIOUS INJURY OR DEATH.
PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
USER GUIDE 087-0047, Rev. G

087-0047, Rev. G/December 2019
PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
USER GUIDE
ii
Copyright © Teledyne Gas Measurement Instruments Ltd, December 2019
RELATED PRODUCT DOCUMENTATION
Document Title Document
Number Purpose
Protégé ZM System Guide 087-0048
Installation, configuration, operation, mainte-
nance and troubleshooting information on the
Protégé ZM monitor, test station, applicable soft-
ware and firmware.

087-0047, Rev. G/December 2019
PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
LEGAL STATEMENT
iii
LEGAL STATEMENT
Teledyne, the Teledyne Logo, Gas Measurement Instruments, GMI, and Protégé are registered
and/or unregistered marks of Teledyne Gas Measurement Instruments Ltd, referred to hereafter as
“the Company.”
All rights reserved. No part of this documentation may be reproduced in any form or by any means
or used to make any derivative work (such as translation, transformation, or adaptation) without
written permission from the Company.
The Company reserves the right to revise this documentation and to make changes in content from
time to time without obligation on the part of the Company to provide notification of such revision or
change.
The Company provides this documentation without warranty, term, or condition of any kind, either
implied or expressed, including, but not limited to, the implied warranties, terms or conditions of
merchantability, satisfactory quality, and fitness for a particular purpose. The Company may make
improvements or changes in the product(s) described in this documentation at any time.
While every effort has been made to ensure accuracy in this guide, no responsibility can be
accepted for errors or omissions. This publication is not intended to form the basis of a contract,
and the Company reserves the right to amend the design, content, and specifications of the detec-
tor without notice.
Microsoft, Windows, Windows 2000, Windows Me, Windows XP, Windows NT, Windows Vista,
Windows 7, Internet Explorer and MS-DOS are either trademarks or registered trademarks of Mic-
rosoft Corporation in the United States and other countries. Solaris and JAVA are either trademarks
or registered trademarks of Sun Microsystems, Inc. All other products or service names are the
property of their respective owners.

087-0047, Rev. G/December 2019
PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
iv
This page is intentionally left blank.

PROTÉGÉ ZM
PORTABLE, ZERO MAINTENANCE, SINGLE-GAS MONITOR
TABLE OF CONTENTS
087-0047, Rev. G/December 2019 v
TABLE OF CONTENTS
Sect. # Section Title Page #
1. ABOUT THIS GUIDE .................................................................................................... 1-1
1.1. Guide Conventions..................................................................................................... 1-1
1.2. Certifications and Approvals....................................................................................... 1-2
1.3. General Safety Information ........................................................................................ 1-3
1.4. Warnings and Cautions – Monitor Use and Care ....................................................... 1-4
1.5. Warnings and Cautions – Sensor Use and Care........................................................ 1-5
1.6. Warnings and Cautions – Battery Use and Care........................................................ 1-5
2. INTRODUCTION........................................................................................................... 2-1
2.1. Monitor Overview ....................................................................................................... 2-1
3. OPERATION ................................................................................................................. 3-1
3.1. Operating the Monitor................................................................................................. 3-1
3.1.1. MONITOR LCD DISPLAY........................................................................................ 3-1
3.2. Powering Up the Monitor............................................................................................ 3-2
3.3. Monitor LCD Alerts & Alarms...................................................................................... 3-3
4. MAINTENANCE ............................................................................................................ 4-1
4.1. Bump Testing / O2 Calibration .................................................................................... 4-1
4.1.1. BUMP TEST USING CALIBRATION ADAPTER ..................................................... 4-1
4.1.2. CLEARING A BUMP TEST INTERVAL ALARM ALERT .......................................... 4-2
4.1.3. O2 CALIBRATION USING THE FRONT BUTTON................................................... 4-3
4.2. Self-test ...................................................................................................................... 4-3
4.3. Error Codes ................................................................................................................ 4-5
A. SPECIFICATIONS ........................................................................................................A-1
B. GAS INTERFERENCES ...............................................................................................B-1
B.1. Gas Interferences.......................................................................................................B-1
C. PARTS ......................................................................................................................... C-1
C.1. Applicable Parts List.................................................................................................. C-1
D. TECHNICAL SUPPORT............................................................................................... D-1

087-0047, Rev. G/December 2019
vi
PROTÉGÉ ZM
PORTABLE, ZERO MAINTENANCE, SINGLE-GAS MONITOR
LIST OF FIGURES
LIST OF FIGURES
Fig. # Figure Title Page #
2-1 Major Parts of the Monitor .............................................................................................2-2
3-1 Monitor LCD Indicators..................................................................................................3-1
4-1 Bump Test - Calibration Adapter Attached.....................................................................4-2
4-2 Manual Bump Test - Apply Gas .....................................................................................4-2

PROTÉGÉ ZM
PORTABLE, ZERO MAINTENANCE, SINGLE-GAS MONITOR
LIST OF TABLES
087-0047, Rev. G/December 2019 vii
LIST OF TABLES
Table # Table Title Page #
1-1 Certifications and Approvals.......................................................................................... 1-2
2-1 Available Monitor Options ............................................................................................. 2-1
3-2 Monitor Power-Up Sequence........................................................................................ 3-2
3-3 Monitor Alerts and Alarms Descriptions ........................................................................ 3-3
4-1 Self-Test Procedure....................................................................................................... 4-3
4-2 Error Codes................................................................................................................... 4-5
A-1 Monitor Specifications...................................................................................................A-1
B-1 Gas Interferences..........................................................................................................B-1
C-1 Applicable Parts List..................................................................................................... C-1

087-0047, Rev. G/December 2019
viii
PROTÉGÉ ZM
PORTABLE, ZERO MAINTENANCE, SINGLE-GAS MONITOR
LIST OF TABLES
This page is intentionally left blank.

PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
ABOUT THIS GUIDE
087-0047, Rev. G/December 2019 1-1
1. ABOUT THIS GUIDE
This guide instructs gas detection personnel on the features and usage of the Protégé ZM Portable,
Zero-Maintenance, Single-gas Monitor (also referred to as “the monitor”). It also provides informa-
tion on configuration, operation, maintenance, specifications and trouble shooting.
This user guide assumes the reader has a basic knowledge of gas detection procedures.
The user guide is divided into the following topics:
•INTRODUCTION
•OPERATION
•MAINTENANCE
•SPECIFICATIONS
•GAS INTERFERENCES
•PARTS
•TECHNICAL SUPPORT
1.1. Guide Conventions
The following visual elements are used throughout this guide:
WARNING: THIS ICON AND TEXT INDICATE A POTENTIALLY HAZARDOUS
SITUATION, WHICH, IF NOT AVOIDED, COULD RESULT IN DEATH OR
INJURY.
CAUTION: This icon and text indicate an action or situation, which, if not avoided,
could result in damage to the equipment.
NOTE: This icon and text designates information of special note.

3M™ PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
ABOUT THIS GUIDE
087-0047, Rev. G/December 2019
1-2
1.2. Certifications and Approvals
Table 1: Certifications and Approvals details the monitor’s certifications and approvals.
Table 1: Certifications and Approvals
Mark
Class I, Groups A, B, C, D, and T4
-50°C to +50°C (O2)
-40°C to +50°C (H2S)
-30°C to +50°C (CO)
II1G Ex ia IIC T4 Ga
Ambient temperature:
-50°C to +50°C (O2)
-40°C to +50°C (H2S)
-30°C to +50°C (CO)
ITS 12ATEX27643X
Ex ia IIC T4 Ga
Ambient temperature:
-50°C - +50°C (O2)
-40°C - +50°C, (H2S)
-30°C - +50°C (CO)
IECEx ETL 12.0016X
ATEX Directive
EMC Directive
Note: The monitors covered in this manual have not been evaluated for enriched oxygen atmosphere>21%.

PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
ABOUT THIS GUIDE
087-0047, Rev. G/December 2019 1-3
1.3. General Safety Information
The Company can take no responsibility for use of its equipment if it is not used in accordance with
the instructions. If further operational or maintenance details are required but not provided in this
guide, contact the Company or their agent. The Company shall not be liable for any incidental or
consequential damages in connection with any modifications, errors or omissions in this guide.
All pertinent regional and local safety regulations must be observed when installing and using this
product. For reasons of safety and to assure compliance with documented system data, repairs to
components should be performed only by the manufacturer.
Additionally, industry standards, codes, and legislation are subject to change. Updated copies
should be obtained by users to ensure the most recently issued regulations, standards and guide-
lines are available.
All pertinent regional and local safety regulations must be observed when handling and disposing
of hazardous material, Toxic (E-Chem) Sensors, batteries and other similar items that may fall
under the classification of hazardous material.
The electrical, electronic, and battery elements of this product must not be disposed of via munici-
pal waste streams but should be delivered to collection facilities. Information on collection facilities
is given by the local authorities or importer's representative.
For products sold in Europe, the end of life procedures for battery operated electronic products
must comply with the RoHS Directive 2002/95/EC, the WEEE Directive 2002/96/EC and the Bat-
tery Directive 2006/66/EC. These directives dictate how to dispose of the electronic and battery
elements of the product after use. For Protégé products sold in the UK, contact Teledyne Gas Mea-
surement Instruments Ltd for further information. For other parts of Europe, please contact your
local provider of GMI products.
WARNING: READ, UNDERSTAND AND FOLLOW THE ENTIRE CONTENT OF THIS
GUIDE PRIOR TO USE. FAILURE TO DO SO MAY RESULT IN SERIOUS
INJURY OR DEATH.
WARNING: ALL INDIVIDUALS WHO HAVE OR WILL HAVE RESPONSIBILITY FOR
USING OR TESTING THIS PRODUCT MUST READ AND UNDERSTAND
THE CONTENTS OF THIS MANUAL. THE PRODUCT WILL PERFORM AS
DESIGNED ONLY IF USED AND TESTED IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW
MANUFACTURER'S INSTRUCTIONS WILL RENDER THE WARRANTY
AND APPROVALS NULL AND VOID. FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY ALSO RESULT IN SERIOUS INJURY OR DEATH.
WARNING: THE CAPACITANCE MEASURED ON THE ENCLOSURE'S METAL PARTS
EXCEED 3PF (MAXIMUM MEASURED CAPACITANCE WAS 4.4PF). THE
USER SHALL DETERMINE THE SUITABILITY OF THE EQUIPMENT IN
THE END APPLICATION AND SHALL TAKE THE NECESSARY
PRECAUTIONS IN THE USE OF THIS EQUIPMENT. FAILURE TO DO SO
MAY RESULT IN SERIOUS INJURY OR DEATH.

3M™ PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
ABOUT THIS GUIDE
087-0047, Rev. G/December 2019
1-4
1.4. Warnings and Cautions – Monitor Use and Care
WARNING: ONLY QUALIFIED PERSONNEL — AS DEFINED ACCORDING TO LOCAL,
COUNTY, STATE, FEDERAL AND INDIVIDUAL COMPANY STANDARDS
— MAY OPERATE AND SERVICE THIS EQUIPMENT. READ AND
UNDERSTAND THE GUIDE COMPLETELY BEFORE OPERATING OR
SERVICING.
WARNING: WHEN IN DOUBT VACATE THE AREA IMMEDIATELY. YOU SHOULD
VACATE THE AREA IMMEDIATELY SHOULD THE MONITOR INDICATE A
WARNING OR ALARM CONDITION. YOU SHOULD KNOW, UNDERSTAND
AND FOLLOW YOUR COMPANY'S SAFETY PROTOCOLS.
WARNING: IF THE MONITOR DOES NOT FUNCTION AS DESCRIBED HEREIN,
REMOVE FROM SERVICE AND MARK FOR MAINTENANCE. ONLY USE
GMI REPLACEMENT PARTS WHERE APPLICABLE.
WARNING: ONLY USE THE MONITOR IN ATMOSPHERES FOR WHICH IT IS
INTENDED.
WARNING: TO PREVENT IGNITION OF AN EXPLOSIVE ATMOSPHERE, READ AND
ADHERE TO THE MANUFACTURER'S MAINTENANCE PROCEDURES.
WARNING: READ THIS MANUAL FOR INTRINSIC SAFETY PRECAUTIONS.
SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY,
RESULTING IN SERIOUS INJURY OR DEATH.
WARNING: DO NOT ATTEMPT PART REPLACEMENT OR SUBSTITUTION AS THIS
COULD IMPAIR THE INTRINSIC SAFETY RATING AND WILL VOID THE
WARRANTY OF THE PRODUCT.
ATTENTION: NE PAS ESSAYER DE LA REMPLACER UNE PARTIE OU LA
SUBSTITUTION, CAR CELA POURRAIR NUIRE À LA COTE DE
SÉCURITÉ INTRINSÈQUE ET ANNULERA LA GARANTIE DU PRODUIT.
CAUTION: The monitor only detects gases while powered.
CAUTION: Periodically verify alarm operation by exposing the monitor to a gas
concentration above the high alarm set point.
CAUTION: Verify the gas inlet port is free of dirt and debris prior to use.
CAUTION: Do not expose the monitor to severe mechanical or electrical shock.
Always conduct device startup and bump test procedures after such
exposure to verify the monitor's operation and accuracy.

PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
ABOUT THIS GUIDE
087-0047, Rev. G/December 2019 1-5
1.5. Warnings and Cautions – Sensor Use and Care
1.6. Warnings and Cautions – Battery Use and Care
WARNING: EXTENDED EXPOSURE OF THE MONITOR TO HIGH CONCENTRATIONS
OF TOXIC GASES MAY RESULT IN DEGRADED SENSOR
PERFORMANCE. IF AN ALARM OCCURS DUE TO HIGH
CONCENTRATION OF TOXIC GASES, EXIT TO A SAFE AREA AND
BUMP TEST OR RECALIBRATE AS NECESSARY.
CAUTION: The battery cannot be recharged and is not replaceable.
CAUTION: Discard monitor when battery indicator shows a fully discharged battery.

3M™ PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
ABOUT THIS GUIDE
087-0047, Rev. G/December 2019
1-6
This page is intentionally left blank.

PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
INTRODUCTION
087-0047, Rev. G/December 2019 2-1
2. INTRODUCTION
2.1. Monitor Overview
The Protégé ZM is a portable, single-gas, disposable monitor that operates with a single button and
has a two (2) year life span (typical). It comes ready for use with a lithium-based battery, a filter and
a sensor.
Gas indication is via a direct-reading backlit LCD, multiple bright LEDs, a loud audible alarm and a
vibratory alarm. The monitor includes a downloadable data log for twenty-five (25) events, record-
ing exposures, calibrations, and gas values.
The Protégé ZM monitors the atmosphere for potentially hazardous levels of gases. Three types
are available: Hydrogen Sulfide (H2S), Carbon Monoxide (CO), and Oxygen (O2), as detailed in
Table 1-1: Monitor Types.
For any questions about the monitor or its operation, refer to Section D. TECHNICAL SUPPORT.
NOTE: The monitor is supplied with factory default settings. Some settings can be altered
to suit varying applications.
Table 1-1: Monitor Types
Gas Hibernation Mode Option* Factory Default Alarm Set
Points**
Oxygen (O2)No Low = 19.5%
High = 23.5%
Hydrogen Sulfide (H2S) Yes Low = 10 PPM
High = 15 PPM
Carbon Monoxide (CO) Yes Low = 35 PPM
High = 200 PPM
*Hibernation mode fully switches off the monitor to extend battery life.
This can only be performed with the IR Connect software or Test Station.
When a device is hibernated, the event log is cleared.
** Customer may change these set points using IR Connect after delivery.
To display alarm set points, press the monitor’s button.
Monitors may be ordered with custom alarm set points.

PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
INTRODUCTION
087-0047, Rev. G/December 2019
2-2
Figure 2-1: Major Parts of the Monitor shows the major parts of the monitor.
Figure 2-1: Major Parts of the Monitor
NOTE: The monitor is shipped with a calibration adapter (refer to C.1. Applicable Parts
List).

PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
OPERATION
087-0047, Rev. G/December 2019 3-1
3. OPERATION
3.1. Operating the Monitor
In the absence of gas, the LCD displays life remaining. If gas is present, the display automatically
shows the gas concentration and a battery icon.
To activate the monitor, press and hold the front button for about five (5) seconds. On activation,
the monitor vibrates, flashes and sounds an audible alarm. A successful activation will display 24
months of life remaining.
3.1.1. MONITOR LCD DISPLAY
Figure 3-1: Monitor LCD Indicators details LCD Display.
Figure 3-1: Monitor LCD Indicators
WARNING: IF THE MONITOR FAILS TO RESPOND PROPERLY UPON START UP, OR
IF CALIBRATION IS OUT OF DATE, DO NOT USE THE DEVICE UNTIL IT
HAS BEEN PROPERLY CALIBRATED. FAILURE TO DO SO COULD
RESULT IN DEATH OR INJURY.
NOTE: You can change the monitor’s default display using the IR Connect Software.
WARNING: YOU MUST FAMILIARIZE YOURSELF WITH THE ICONS IN BOTH THE
NON-ALARM AND ALARM STATES.
WARNING: DO NOT USE IF THE DISPLAY IS MISSING ICONS OR CANNOT BE
CLEARLY READ.
Alarm Condition
Self Test Check
Test Reminder
Gas Type
Alarm Conditions
Life Remaining
Infra Red Data Transfer
Gas Reading Units
Time Since Last Maximum Exposure / Life Remainnng
Life Remaining or Gas Reading
Battery Indicator
Gas Reading Units
Reading Displayed is
Last Maximum Exposure

PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
OPERATION
087-0047, Rev. G/December 2019
3-2
3.2. Powering Up the Monitor
WARNING: DO NOT USE THE MONITOR IF IT DOES NOT OPERATE AS DESCRIBED
HERE.
Table 3-1: Monitor Power-Up Sequence
Action LCD Display Results
Press & hold
the button for
five (5)
seconds.
The monitor starts and runs through a self-test:
• The monitor emits one audible beep
• All LEDs light and monitor vibrates
• All LCD display elements appear
Next, the LOW and HIGH alarm set points are displayed.
When a self-test is successful, the monitor emits one short
beep and displays:
•self-test check icon
•months / life remaining icon

PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
OPERATION
087-0047, Rev. G/December 2019 3-3
3.3. Monitor LCD Alerts & Alarms
Table 3-2: Monitor Alerts and Alarms Descriptions
LCD Reason LED Beeps Vibration
Low Alarm 1 slow flash every
second
1 slow beep every
second
1 slow vibration
every second
High Alarm and
Over Limit (OL)
Alarm
2 fast flashes
every second
2 fast beeps every
second
2 fast vibrations
every second
Detector Life
Countdown
Alarm*
8 slow flashes per
minute
8 slow beeps per
minute
8 slow vibrations
per minute
Bump Test Due**
Note: LCD toggles
between buP &
reading.
Alternating flashes
(left and right)
every 5 seconds
* When Life Remaining displays 0 hours, the detector operates for 8 hours before deactivating.
** Applies if a bump test interval is set.

PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
OPERATION
087-0047, Rev. G/December 2019
3-4
This page is intentionally left blank.
Table of contents
Other Teledyne Monitor manuals