TECHNICAL CHARACTERISTICS
APPLICATION DIAGRAM
Figure 1. Floor by oor installation powered from SA51.
Type SA51 SA51D
Frequency range SAT IF 950-2400 MHz
Terr. TV 47-862 MHz
Gain SAT IF, adjustable 22 dB (0 ÷ -15 dB) by 1 dB step
Terr. TV, adjustable 22 dB (0 ÷ -15 dB) by 1 dB step
Slope SAT IF, switchable 0/3/5/7 dB
Terr. TV, switchable 0/6/12/18 dB
Isolation SAT/SAT 30 dB
SAT/Terr. TV 30 dB
Noise figure, typical ≤9 dB
Output level IMD3=60 dB(DIN45004B) Terr. TV**** 109 dBµV
Output level IMD3=35 dB (EN50083-3) SAT IF**** 114 dBµV
External equipment through V lines 14 V 0.5 A max. (switchable) -
powering through H lines 18 V 2 A* max. (switchable) -
through Terr line 12 V 0.1 A max. (switchable) -
DC pass through, switchable through H lines 2 A* max.
Supply voltage limit values, power consumption 198-250 V~ 50/60 Hz 5 W** DC 9-18 V 4 W***
Operating temperature range -20o÷ + 50oC
Dimensions/Weight (packed) 284x135x52 mm/1 kg 178x135x32 mm/0.6 kg
* 1 A max. through one line
** without external DC loading; with maximal external DC load - 57 W
*** in line powering of SA51D through H lines
**** measured using 2 equal signals
OPERATING
A multichannel amplier consists of highly isolated individual ampliers for every incoming line. Gain and slope controls of
each amplier are located between input and output connectors of corresponding line.
Gain regulation is performed by two step attenuators. The rst rough control attenuator has 4 possitions with 4 dB steps
and the second ne control attenuator has 4 possitions with 1 dB steps. The gain of amplier is dened by subtracting joint
attenuation of both attenuators from maximum gain.
Slope control has 4 positions. The value of each position determines the difference of gain at highest and lowest frequencies.
Amplier SA51 provides voltages 18 V to all horizontal polarization connectors, 14 V to all vertical polarization connectors
and 12 V to Terrestrial TV input connector. The switches on the output side allows disconnect voltages of 18 V and 14 V from
output connectors. This is usefull in large networks for prevention of interference between power supply units, when several of
them are incorporated. The switch on the input side allows disconnecting of voltage 12 V from from terrestrial TV input line to
avoid short-circuiting of power supply if terrestrial amlier with remote powering is not installed. All voltage sources have short
circuit protection with LED indicators. Green light on them indicates normal operation. The red light signals that short-circuit
emerged in corresponding line or power supply is overloaded (in the case of overloading 18 V red light will be intermittent).
After that amplier SA51 must unplugged from mains and network must be repaired. Do not plug amplier to mains again until
30 sec. time will pass.
Amplier SA51D is powered from central network power supply (for example SA51) through horizontal polarization lines.
Both lines regarding DC are interconnected to minimize voltage loss in lines. It consumes up to 0.2 A from 18 V power supply.
Amplier has connector for auxilary power supply if voltage from central power supply is not accessible. If it is plugged voltage is
distributed to horizontal polarization lines in the same way as SA51. In every case presence of voltage in lines will be indicated
by green LEDs near the corresponding switch. Voltage 12 V in the input connector of Terrestrial path will be only if 18 V is
present in horizontal polarization lines.
Both ampliers SA51 and SA51D has DC through path in every Satellite TV line. It provides exibility for installation of power
supply units inside the network.
Caution.
Risk of electric shock.
This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled
or discarded according to applicable local and national regulations.
Equipment intended for indoor usage only.
Apparatus is double insulated from the mains.
Functional grounding. Connect to the main potential equalization.
TERRA conrms, that this product is in accordance to following norms of EU EMC norm
EN50083-2, safety norm EN60065, RoHS norm EN50581.
TERRA confirms, that this product is in accordance to following norms of Russian Federation: EMC
ГОСТ Р 51318.22-2006, ГОСТ Р 51318.24-99, ГОСТ Р 51317.3.2-2006, ГОСТ Р 51317.3.3-2008 and safety norm