English Operating Manual
Management remote control
SendoPro 868-A
Table of contents
1. Usage....................................59
2. Function and performance ....................60
3. ...........61
4. Information about this operating manual .........61
5. Data exchange .............................62
6. ..........................63
7. Switching remote control on/off ................66
8. Register 1 and 2: Edit parameter set .............67
9. Register 3: Diagnostic and statistic ..............72
10. Register 6: Settings..........................73
11. Detector response...........................75
12. Update...................................76
13. Troubleshooting ............................77
14. Technical data .............................78
15. Guarantee bond ............................79
16. .........80
5959
GB
Thank you for purchasing an Theben HTS presence detector and putting your trust in us.
1. Usage
use contractually agreed upon between the manufacturer and user. Another or a use in excess thereof does not apply according to the terms of the
contract. The manufacturer accepts no liability for damages resulting from such use.

6060
2. Function and performance
HTS presence detectors
uninstalling detectors
to the detector
Readout diagnosis and statistic data
SD card slot
6161
GB
3.
-
-
-
-
-
-
-
-
-
-
4. Information about this operating manual
Notation
[ ....] : Key names
6262
SendoPro
SD-Card
PlanoCentro
Function Description
Read-out -
nication. See page 70.
Send
page 70.
Update
5. Data exchange
working memory
Templates
compact
Update
Load

6363
GB
1236
Edit parameter set
Object -
Parameter set Office
Type PlanoCentro 101-A-230V
Brightness setpoint A 500 lx
Room corr. Factor A 0.3
Actual brightness A 537 lx
Switch-off delay time A 15 min
Short-presence A On
Function channel H Presence
Switch-off delay time H 15 min
Send all Menu
2
4
5
1
3
6. Operating controls
6.1 Display
1 Register for grouping functions
2
3 Register name
Register
1
2
3 Diagnosis and statistics
6 Settings
1236
Edit parameter set
Object -
Parameter set Office
Type PlanoCentro 101-A-230V
Brightness setpoint A 500 lx
Room corr. Factor A 0.3
Actual brightness A -
Switch-off delay time A 15 min
Short-presence A On
Function channel H Presence
Switch-off delay time H 15 min
Send all Menu
1236
Edit parameter set
Object -
Parameter set Office
Type PlanoCentro 101-A-230V
Brightness setpoint A 500 lx
Room corr. Factor A 0.3
Actual brightness A -
Switch-off delay time A 15 min
Short-presence A On
Function channel H Presence
Switch-off delay time H 15 min
Send all Menu
1236
Diagnostic und statistic
Type PlanoCentro 101-A-230V
Software version 1.01
Hardware state OK
Parameter state OK
Rotary switch position SW1 OK (2)
Number of parallel signals 2549
Operating hours light A 534 h
Operating hours presence H 727 h
Read-out data Menu
1236
Setup
Device switch-off timer 5 min
LCD brightness Level 3
LCD switch-off timer 30 s
Language English
SendoPro-Info
Reset device settings
Software update
4 Data area
5
6464
6.2 Keys
Key Description
Function
keys
c
see following page
Function key lettering can be found at the bottom
of the display on the right and left side. Function
keys are allocated according to context dependant
-
ched.
Key up
-
-Select parameter
Key down
-
-Select parameter
Key left
<
-Displays the register on the left of the current register
-
Key Description
Key right
>
-Displays the register on the right of the current register
-
Back -
-
OK -Execute action/function
-
-Selecting in menu
-
-Quick access to the most important function in the cursor
position context. See page 68.
Send
On/Off
6565
GB
6.3 Batteries
Battery status
The battery status display depends on the battery type used. The status
display applies to non-
c

6666
6.4 Function menu
c
7. Switching remote control on/off
Switching the remote control on
g.
switched on.
Switching the remote control off
g.
be set in register 6.
1236
Edit parameter set
Object -
Parameter set Office
Type PlanoCentro 101-A-230V
Brightness setpoint A 500 lx
Room corr. Factor A 0.3
Actual brightness A -
Switch-off delay time A 15 min
Short-presence A On
Function channel H Presence
Switch-off delay time H 15 min
Send all Menu
c
6767
GB
1
-
-
-Detector type
2
-
parameters are listed.
3 Scroll bar
8. Register 1 and 2: Edit parameter set
register 1 and register 2 enable comparisons of parameters and parameter sets.
1236
Edit parameter set
Object -
Parameter set Office
Type PlanoCentro 101-A-230V
Brightness setpoint A 500 lx
Room corr. Factor A 0.3
Actual brightness A -
Switch-off delay time A 15 min
Short-presence A On
Function channel H Presence
Switch-off delay time H 15 min
Send all Menu
2
3
1
6868
8.1 Short-cut functions
Cursor position Key Function
Object [Menu]
Parameter set
[Menu]
Type
The parameters for the selected detector are displayed in the parameter list.
[Menu]
Parameter
[Send] The selected parameter is sent to detector.
[Menu]
<Send all> All parameters of the shown parameter set are sent to the presence detector.

6969
GB
8.2 Parameter set menu
1. Mark parameter set
2. Select <Menu>
Function Description
Load
-
8.3 Type menu
8.4 Search type
The management remote control must be set to the correct detector
> and <Search> the detec-
tor type can be determined.
1. Mark detector type
2. Select <Menu>
3. Select <Edit>
Function Description
Search
Search
1. The list of detector types is displayed.
2. > und
<Search> the detector types in the list are selected
one by one.
The detector indicates the correct type selection by means
selection of the type will be indicated by a brief
one-time illumination of the LED.
Function Description
Edit
1. ] [
2.
-If the buttons [] or [
Read-out data
Control
commands
1. Mark detector type 2. Select <Menu>
7070
8.5 Parameter menu
1. Mark parameter
2. Select <Menu>
Function Description
Edit
1. Select <Edit>
2. ] [
3.
-If the buttons [] or [
Read-out data
Control
commands
8.6 Send parameter
The displayed parameter set must correspond with the detector type installed.
Send individual parameter 1. Select the parameter with the [] [
2.
Send parameter set
<Send all>
1. Mark one parameter
2.
L
8.7 Read-out parameters
Procedure:
1. Mark a parameter
2. <Menu> <Read-out data>
7171
GB
8.8 Parameters set read-out completed
Object
Parameter set
Type Detector type whose parameter were read-out.
Parameter list
Actual brightness
8.9 Control commands
The control commands are listed according to the selected detector type.
Procedure for control commands:
1. Select <Menu>
c
2. d
3. Use the function keys to perform the control commands.
1236
Edit parameter set
Object -
Parameter set Office
Type PlanoCentro 101-A-230V
Brightness setpoint A 500 lx
Room corr. Factor A 0.3
Actual brightness A -
Switch-off delay time A 15 min
Short-presence A On
Function channel H Presence
Switch-off delay time H 15 min
Send all Menu
cd
1236
Edit parameter set
Object -
Parameter set Office
Type PlanoCentro 101-A-230V
Menu - Parameter
Edit
Control commands Read-out data
1236
Edit parameter set
Object -
Parameter set Office
Type PlanoCentro 101-A-230V
Brightness setpoint A 500 lx
Room corr. Factor A 0.3
Actual brightness A 537 lx
Switch-off delay time A 15 min
Short-presence A On
Function channel H Presence
Switch-off delay time H 15 min
Send all Menu

7272
9. Register 3: Diagnostic and statistic
Register 3 contains the detector diagnostic and statistic data. The data displayed depend on the detector type.
Procedure for reading data
-c
9.1 Diagnostic and statistic menu
1.
2. Select <Menu>
Function Description
Check P-terminal overload
Reset statistic value
Reset operating hours Reset all operating hours in the detector.
1236
Diagnostic und statistic
Type PlanoCentro 101-A-230V
Software version 1.01
Hardware state OK
Parameter state OK
Rotary switch position SW1 OK (2)
Number of parallel signals 2549
Operating hours light A 534 h
Operating hours presence H 727 h
Read-out data Menu
c
7373
GB
10.Register 6: Settings
Parameter Description
Device switch-off timer
LCD brightness
LCD switch-off timer
Language
SendoPro-Info
Reset decice settings
g.
Software update
7474
10.1 Software update
Procedure:
1.
2.
3.
4. Insert SD-card
5. Select register 6
6. Select function <Software update>
-The update process is shown on the display.
7.
8. The successful completed software update is displayed.
9.
10.
!

7575
GB
11.Detector response
Detailed information can be found in the presence detector operation manual.
11.1 Receiving a value/command
11.2
11.3 Local potentiometer settings
L
11.4 Power loss
7676
11.5 Special case: KNX presence detectors
-
Selecting the programming mode. The LED on the front side indica-
tes when the detector is in programming mode.
is explained in the presence detector operating instructions.
seconds. If it is not a Master it will be indicated by a brief one-time
illumination of the LED.
-
on of the LED.
12.Update
-
For implementing a program and language update see page 74.
7777
GB
13.Troubleshooting
Fault Cause / Remedy
display goes off again.
Aim the remote directly at the detector when sending; distance from detector is too great; check detector type in
the remote; detector not remote controlled

7878
14.Technical data
Management remote control SendoPro 868-A
Supply voltage 6V
Batteries 4xAA, 2500 mAh, 1.5 V
Transmission medium for sending Infrared (IR)
Transmission medium for receiving Radio
Radio frequency 868MHz
Range IR
Approx. 8m
Emission angle r15°
External memory SD card (SD, SDHC)
Dimensions 190 x 82 x 25 mm
Ambient temperature mode 0° - +50°C
Ambient temperature -20° - +60°C
Colour Black
Item numbers
SendoPro 868-A 907 0 675
SD card Accessories 907 0 676
14.1 !"
CE declaration of conformity
-
-
-
-
-
-
-
-
-
-compact passage
-compact passage 24V
-
-compact passimo
-
-
-
7979
GB
15.Guarantee bond
adhered to.
or lacking models up to the end of the guarantee period.
Dispatching
Industrial property rights
8080
16.
Application
Parameter
Common
room / area
# #
bright
#
dark
Corridor Corridor
bright
Corridor
pulse
Corridor
pulse
WC
Brightness set point value A 400 500 800 200 200 400 100 200 Meas. of
Room correction factor A 0.3
Switch-off delay time A 15 min 10 min Impulse 10 min
Short-presence A
Function channel H
Switch-off delay time H 15 min 10 min
Switch-on delay time H 0 s 1 min
Function mode auto
Staircase light function
Control input S1 auto
Detection sensitivity
Surveillance sens. reduction
Group address All
Scene 1
Scene 2

8181
GB
AB
LUX t
off
t
off
t
on
# 4.0 15 min 15 min 0 sec
# 5.0 15 min 15 min 0 sec
#$ 3.0 15 min 15 min 0 sec
Passage 3.0 10 min 10 min 0 sec
Restroom on 10 min 10 min 1 min
AB
LUX t
off
t
off
t
on
Passage 3.0 10 min 10 min 0 sec
Passage clear 4.0 10 min 10 min 0 sec
Passage dark 2.0 10 min 10 min 0 sec
A
LUX t
off
Standard room 4.0 15 min
Passage 3.0 10 min
Restroom 10 min
Wet room 3.0 15 min
8282
A
LUX t
off
# 4.0 15 min 0 sec
# 5.0 15 min 0 sec
#$ 3.0 15 min 0 sec
Passage 3.0 10 min 0 sec
A
LUX t
off
# 4.0 15 min
# 5.0 15 min
#$ 3.0 15 min
Passage 3.0 10 min
AB
LUX A t
off LUX B
# 4.0 15 min 4.0
# 5.0 15 min 5.0
#$ 3.0 15 min 3.0
8383
GB

Theben AG
Hotline
Switzerland
Theben HTS AG
www.theben-hts.ch
Table of contents
Other Theben Remote Control manuals