manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Thorn
  6. •
  7. Outdoor Light
  8. •
  9. Thorn EP 445 LED User manual

Thorn EP 445 LED User manual

EP 445 LED
220 - 240V 50/60Hz IP66 IK08
Dimensions:
Weight (kg)
SCx max (m²)
SCx lat (m²)
Light emission direction :
1. Post top installation
1/2207083548 (22/12/2017)
8,0
0,190
0,086
2. Cabling of the post top mounted variant
1.1
695436
436
4
27
36
Tools:
For fixing to female post a ¾ gas pin is available on demand.
3/4 Gas
10Nm
(4x) 2Nm
(4x) M4x10
1.2
90°
1.3
1.4
(2X)
(2x) 2Nm
(2x) M4x10
A. Option 1 - cable fixing (cable Ø12 - 14 mm) B. Option 2 - cable fixing (cable Ø10 - 12 mm)
(2x) 2Nm
(2x) M4x10
2.1
2.2
2.3
2.1
2.3
CLIK!
Ø 10-14mm
5Nm
CLIK!
M5x20
5Nm
8
20
2.2
2.4
2.5
2.6
4. Maintenance
3. Closing
3.1
3.2
Led
2/2
6. Power supply unit replacing
1 2
21
6.6
6.1
6.2 6.3
6.4
6.5 6.6
6.7 6.8 6.9 6.9
6.10
5. Dimming options
output power
Profile 1
on T1 Mid T2 off on
output power
T1 Mid T2
Profile 2
off
POSITIONS
output power
Profile 3
on T1 Mid T2 off
output power
Profile 4
on T1 Mid T2 off
0= profile 4 / 700mA
T1: MID -3h / T1: MID +5h
reduction 50%
(standard position)
1= profile 2 / 700mA
T1: MID -2h
reduction 70%
2= profile 3 / 700mA
T1: MID -0h
reduction 70%
3= profile 2 / 700mA
T1: MID -1h
reduction 70%
5= profile 4 / 525mA
T1: MID -3h / T1: MID +5h
reduction 50%
6= profile 2 / 525mA
T1: MID -2h
reduction 70%
7= profile 3 / 525mA
T1: MID -0h
reduction 70%
8= profile 2 / 525mA
T1: MID -1h
reduction 70%
9= profile 1 / 525mA
4000 °K 1R 2R
Pos. Reduction Lm w Lm w
050% 1.433 15 2.880 29
170% 2.006 20 4.032 41
270% 2.006 20 4.032 41
370% 2.006 20 4.032 41
4100% 2.865 29 5.760 58
550% 1.128 11 2.275 22
670% 1.579 15 3.185 30
770% 1.579 15 3.185 30
870% 1.579 15 3.185 30
9100% 2.255 21 4.550 43
A50% 793 7 1.600 14
B70% 1.110 10 2.240 20
C70% 1.110 10 2.240 20
D70% 1.110 10 2.240 20
E100% 1.585 14 3.200 28
A= profile 4 / 350mA
T1: MID -3h / T1: MID +5h
reduction 50%
B= profile 2 / 350mA
T1: MID -2h
reduction 70%
C= profile 3 / 350mA
T1: MID -0h
reduction 70%
D= profile 2 / 350mA
T1: MID -1h
reduction 70%
E= profile 1 / 350mA
4= profile 1 / 700mA
FRANCAIS
-Remplacer toute protection fissurèe.
-Les luminaires classe II doivent être
installês de façon â ce que la partie
mêtallique ne soit pas en contact avec
l'installation êlectrique connectêe â la terre.
ATTENTION :
-Ce luminaire fonctionne â une tension
nominale qui doit être coupêe avant
toute intervention sur l'appareillage.
-Toute modification de cet appareil est
interdite.
SVERIGE
-Ersätta alla spräckta skyddspätar .
-Klass II armaturer mäste installeras sä
att nakna metalldelar i armaturen inte
är i kontakt med nägon elektrisk
installation, kopplad till en skyddledare.
VARNING :
-Denna armatur fungerar med högspänning
som mäste vara fränslagen fore ingripande
i driftdonen.
-Alla ändringar i denna armatur är förbjuden.
ITALIANO
-Sostituire sempre tutte le protezioni
danneggiate.
-Gli apparecchi in classe II devono essere
installati in modo che le parti metalliche
non siano in contatto con apparati elettrici
collegati a terra.
ATTENZIONE :
-Questo apparecchio funziona a tensione
nominale, questa deve essere interrotta
prima di ogni intervento sul gruppo di
alimentazione.
-Ogni modifica dell'apparecchio è proibita.
ENGLISH
-Replace any cracked protective shield.
-Class II luminaires must be installed so
that exposed metal work of the electrical
installation connected to a
protective conductor.
WARNING :
-This luminaire operates at mains voltage
which must be switched off before
intervention in control gear.
-Any modification to this luminaire is
forbidden.
DEUTSCH
-Ersetze jede gebrochene Schutzscheibe.
-Schutzklasse II Leuchten müssen so
installiert werden, da berührbare Metallteile
nich mit einem, an dem Schutzleiter
angeschlossenen Teil der elektrischen
Installation in Kontakt kommen können.
ACHTUNG :
-Diese Leuchte wird mit Netzspannung betrieben.
Bevor Eingriffe am Vorschaltgerät vorgenommen
werdwn sowie vor Wartung und Installation,
ist die Versorgungsspannung abzuschalten.
-Jede Änderung an dieser Leuchte ist verboten.
SUOMI
-Rikkoontunut suojalasi vaihdettava
välittömästi uutsen vastaavaan.
-Asennettaessa suojausluokan II
valaisinta on peruseristetyn johdon
ja kosketelttavien metalliosien
välinen kosketus tehokkaasti
eristettãvä .
VAROITUS :
-Verkkojännite on kytkettãvä pois ennen
valaisimen houltotoimenpiteitä.
-Valaisimen rakannetta el saa muuttaa.

Other Thorn Outdoor Light manuals

Thorn SIMILO ROUND User manual

Thorn

Thorn SIMILO ROUND User manual

Thorn THOR BOLLARD Series User manual

Thorn

Thorn THOR BOLLARD Series User manual

Thorn Areaflood Pro 2 User manual

Thorn

Thorn Areaflood Pro 2 User manual

Thorn ISARO PRO User manual

Thorn

Thorn ISARO PRO User manual

Thorn AFP M Series User manual

Thorn

Thorn AFP M Series User manual

Thorn PROMENADE  LED User manual

Thorn

Thorn PROMENADE LED User manual

Thorn OLSYS 1 STREET User manual

Thorn

Thorn OLSYS 1 STREET User manual

Thorn RAZE ARCHI LARGE User manual

Thorn

Thorn RAZE ARCHI LARGE User manual

Thorn VOLUPTO VO 18L105-740 SF RS CL2 W5 T60 ANT User manual

Thorn

Thorn VOLUPTO VO 18L105-740 SF RS CL2 W5 T60 ANT User manual

Thorn AFP L Series User manual

Thorn

Thorn AFP L Series User manual

Thorn D-CO User manual

Thorn

Thorn D-CO User manual

Thorn THOR L Series User manual

Thorn

Thorn THOR L Series User manual

Thorn AVENUE W300 II User manual

Thorn

Thorn AVENUE W300 II User manual

Thorn CIVITEQ S User manual

Thorn

Thorn CIVITEQ S User manual

Thorn CIVITEQ User manual

Thorn

Thorn CIVITEQ User manual

Thorn AVENUE F2 AVF 18L50-730 RS CL BS 3550 CL2... User manual

Thorn

Thorn AVENUE F2 AVF 18L50-730 RS CL BS 3550 CL2... User manual

Thorn DYANA 1 User manual

Thorn

Thorn DYANA 1 User manual

Thorn ADELIE WIDE User manual

Thorn

Thorn ADELIE WIDE User manual

Thorn OXANE L User manual

Thorn

Thorn OXANE L User manual

Thorn EP 145 LED User manual

Thorn

Thorn EP 145 LED User manual

Thorn Clan O User manual

Thorn

Thorn Clan O User manual

Thorn DYANA LED MLE Series User manual

Thorn

Thorn DYANA LED MLE Series User manual

Thorn ADELIE BOLLARD WIDE User manual

Thorn

Thorn ADELIE BOLLARD WIDE User manual

Thorn R2L2 XS User manual

Thorn

Thorn R2L2 XS User manual

Popular Outdoor Light manuals by other brands

Daintree GE current Evolve EPTC Series installation guide

Daintree

Daintree GE current Evolve EPTC Series installation guide

Neutron 2100 instructions

Neutron

Neutron 2100 instructions

LIGMAN KIOS 2 installation manual

LIGMAN

LIGMAN KIOS 2 installation manual

iGuzzini LIGHT UP BB38 instruction sheet

iGuzzini

iGuzzini LIGHT UP BB38 instruction sheet

LIGMAN LADOR 3 installation manual

LIGMAN

LIGMAN LADOR 3 installation manual

GTV GRANDE Assembly instruction

GTV

GTV GRANDE Assembly instruction

LIGMAN ABERDEEN 2 installation manual

LIGMAN

LIGMAN ABERDEEN 2 installation manual

Philips 168578716 user manual

Philips

Philips 168578716 user manual

Springdale Lighting STR11010 Assembly instructions

Springdale Lighting

Springdale Lighting STR11010 Assembly instructions

Trilux 8841 LS Series Mounting instructions

Trilux

Trilux 8841 LS Series Mounting instructions

Kichler Lighting 15066AZT manual

Kichler Lighting

Kichler Lighting 15066AZT manual

Sea gull lighting Brentwood 8822BLE installation instructions

Sea gull lighting

Sea gull lighting Brentwood 8822BLE installation instructions

RAB WPLED20 installation instructions

RAB

RAB WPLED20 installation instructions

Cooper Lighting ALL-PRO AL2050LPCBZ instruction manual

Cooper Lighting

Cooper Lighting ALL-PRO AL2050LPCBZ instruction manual

Trilux 8841 LS Series Mounting instruction

Trilux

Trilux 8841 LS Series Mounting instruction

Inowel 22529 Intended use

Inowel

Inowel 22529 Intended use

GE PM 16 instructions

GE

GE PM 16 instructions

Kartell Bourgie manual

Kartell

Kartell Bourgie manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.