manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Thorn
  6. •
  7. Outdoor Light
  8. •
  9. Thorn WeatherForce LED User manual

Thorn WeatherForce LED User manual

Other Thorn Outdoor Light manuals

Thorn RAZE BOLLARD Series User manual

Thorn

Thorn RAZE BOLLARD Series User manual

Thorn OXANE User manual

Thorn

Thorn OXANE User manual

Thorn AFP L Series User manual

Thorn

Thorn AFP L Series User manual

Thorn D76L740 User manual

Thorn

Thorn D76L740 User manual

Thorn Clan O User manual

Thorn

Thorn Clan O User manual

Thorn ISARO PRO User manual

Thorn

Thorn ISARO PRO User manual

Thorn Voyager Twinspot User manual

Thorn

Thorn Voyager Twinspot User manual

Thorn Areaflood Pro 2 User manual

Thorn

Thorn Areaflood Pro 2 User manual

Thorn URBA DECO User manual

Thorn

Thorn URBA DECO User manual

Thorn EP 445 LED User manual

Thorn

Thorn EP 445 LED User manual

Thorn EFACT R/C00 SLIM Series User manual

Thorn

Thorn EFACT R/C00 SLIM Series User manual

Thorn ISARO PRO User manual

Thorn

Thorn ISARO PRO User manual

Thorn ORUS LED User manual

Thorn

Thorn ORUS LED User manual

Thorn EP 145 LED User manual

Thorn

Thorn EP 145 LED User manual

Thorn MILO GOBO NM User manual

Thorn

Thorn MILO GOBO NM User manual

Thorn AVENUE F2 User manual

Thorn

Thorn AVENUE F2 User manual

Thorn SIMILO ROUND User manual

Thorn

Thorn SIMILO ROUND User manual

Thorn PLURIO IND User manual

Thorn

Thorn PLURIO IND User manual

Thorn SATIN 2 MWA L330 User manual

Thorn

Thorn SATIN 2 MWA L330 User manual

Thorn PROMENADE  LED User manual

Thorn

Thorn PROMENADE LED User manual

Thorn R2L2 XS User manual

Thorn

Thorn R2L2 XS User manual

Thorn ADELIE WIDE User manual

Thorn

Thorn ADELIE WIDE User manual

Thorn OXANE L User manual

Thorn

Thorn OXANE L User manual

Thorn BASALT User manual

Thorn

Thorn BASALT User manual

Popular Outdoor Light manuals by other brands

Sealey LED37 instructions

Sealey

Sealey LED37 instructions

nordlux VEJERS Mounting instruction

nordlux

nordlux VEJERS Mounting instruction

SImx ELITE LED LHTC637 installation instructions

SImx

SImx ELITE LED LHTC637 installation instructions

GEV CAROLINE 10833 manual

GEV

GEV CAROLINE 10833 manual

WE-EF PFL540 LED Installation and maintenance instructions

WE-EF

WE-EF PFL540 LED Installation and maintenance instructions

Lindby 9949029 Intended use

Lindby

Lindby 9949029 Intended use

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

HEPER

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

Maretti VIBE S 14.6080.04.A quick start guide

Maretti

Maretti VIBE S 14.6080.04.A quick start guide

BEGA 84 253 Installation and technical information

BEGA

BEGA 84 253 Installation and technical information

HEPER LW8034.003-US Installation & maintenance instructions

HEPER

HEPER LW8034.003-US Installation & maintenance instructions

HEPER MINIMO Installation & maintenance instructions

HEPER

HEPER MINIMO Installation & maintenance instructions

LIGMAN BAMBOO 3 installation manual

LIGMAN

LIGMAN BAMBOO 3 installation manual

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maretti

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maxim Lighting Carriage House VX 40428WGOB installation instructions

Maxim Lighting

Maxim Lighting Carriage House VX 40428WGOB installation instructions

urban ambiance UQL1273 installation instructions

urban ambiance

urban ambiance UQL1273 installation instructions

TotalPond 52238 instruction manual

TotalPond

TotalPond 52238 instruction manual

Donner & Blitzen 0-02661479-2 owner's manual

Donner & Blitzen

Donner & Blitzen 0-02661479-2 owner's manual

LIGMAN DE-20023 installation manual

LIGMAN

LIGMAN DE-20023 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

IP65
IP65
IP65 IP65
IP65 IP65
WeatherForce LED
Installation Instructions
Warning
Please read these instructions carefully before installation or lamp
replacement. Warranty of this product is subject to installation
and maintenance being carried using appropriate conventional
practices and/or any specic instructions enclosed within.
Installation must be carried out by a qualied electrician in
accordance with local wiring regulations. Ensure that the rated
voltage and frequency of the luminaire are compatible with the
electrical supply.
Disconnect mains power supply before installing, servicing or
maintaining the luminaire.
Changes to specication
The right is reserved to change the design and/or specication
without prior notice or public announcement.
Specication
This luminaire is designed to comply with
the requirements of AS/NZS 60598.
Supply Voltage: 240v ~ 50Hz
Classication For Protection: Against electric shock:
Class 1 earthed metalwork. This luminaire must be earthed.
IP Rating: 65 - A 6-10mm Ø, circular electrical supply
cable must be used to maintain the IP rating.
Maximum ambient operating temperature:
Up to Ta: 25�C
1. Remove the diffuser and gear tray
Product application
IP65
To install, remove diffuser, detach gear tray and maintenance suspension devices.
Installation positions and IP rating
This strong impact resistant product is made from Polycarbonate.
This material is ideal in waterproof & industrial applications.
However, it is not suitable for use in areas prone to contact with
solvents, detergents, oil, alkalis, organic chemicals, animal fats &
industrial cleaners.
Please contact your local Thorn ofce for suitable alternative
products to suit the above applications
Remove Screws
Suspended Mounting Direct Mounting
600mm Single
416mm 507mm
600mm Twin
1200mm Single
880mm 980mm
1200mm Twin
Green/Yellow Earth
Brown Active
Blue Neutral
1
2
3
SAP No: 96540006 Rev: A 1/2013
thn_weatherforce_0113
Thorn Lighting Pty Limited (ABN 74 060 142 501)
Head Ofce: 43 Newton Road, Wetherill Park NSW 2164
Ph. 1300 139 965 Fax. 1300 139 953 www.thornlighting.com.au
Attach the gear tray to the
base. Tighten screws rmly.
Fit the uorescent lamp (ordered
separately).
Attach the diffuser to the base.
Ensure the diffuser is locked in
place.
Mounting kits suitable for surface mounting, or suspension mounting
are available to order.
Order reference: Single - 96039252, Twin - 96039253.
5. Secure the gear tray to the base
8. Attach the diffuser
Mounting kits
Make the electrical connections at the terminal block.
4. Make the electrical connections
The WeatherForce can be mounted by direct screw xing through the
housing. It should only be drilled at the appropriate marked points where
the housing is suitably reinforced. Do not use oil.
Note: Fixing screws and washers are NOT supplied.
It is recommended drill bits specically designed for plastic are used.
Standard metal or timber twist drills may be used but if not properly
prepared for plastic they can instigate stress cracking which may spread
under load.
Do not overtighten any screws into or in contact with the plastic housing.
Permanent damage may occur even if not immediately obvious.
Recommended maximum torque 1.5Nm
It is recommended that installation is made using the end entry and gland
kit provided with the tting.
Warning: If the housing is pierced for back entry of cabling, do not run
mains cabling past ballast, Temperatures exceed 100°C.
Fit the electrical supply cable, conduit and cable gland to the entry point
on the base. Ensure the cable gland is tightened rmly.
Note: If not suitably sealed with
appropriate washers, glands
or proprietary sealing kits any
piercing of the housing will
interfere with the IP rating of
the product.
2. Mount the luminaire
3. Attach conduit, cable glands and electrical
supply cable to tting.
Mounting point
Mounting screws
Cable gland
Suspension mounting kit
Surface mounting kit
Screw
Washer