TimeTec SBTL8033 User manual

SBTL8033
Single Lane Speed Gate
Installation Guide
PREPARATION
1. Tools: a measuring tape, an adjustable wrench, an im-
pact drill and a small screwdriver (included in the pack-
age).
2. Material: a PVC anti-fire and insulation tube (diameter
≥25mm), standard three-core power extension wire,
tether cable (random configuration), M12 expansion
screws (included in the package).
3. Thread the connection wire of the device through the
tube before assembly.
4. The power and signal wires should be set separately to
easily distinguish strong and weak power. Please invite
professional personnel to complete the wiring.The de-
vice must be connected to the ground.
Below is the outline and dimensions:
INSTALLATION
1. Prepare the tools for product installation and sort out
the auxiliaries according to the packing list.
2. Drill holes after determining the hole positions based on
the mounting template as shown in below. Insert the ex-
pansion bolt into the holes accordingly.
3. Tighten the nut preliminarily, then connect the master
and slave devices with wires.
w w w . t i m e t e c c l o u d . c o m

4. Test the operations of the device after connecting it to
the power supply with the temporary cable. Make sure
that the ground wire of AC power is connected to the
cabinet of the device.
5. Turn on the air switch to test whether the device is work-
ing properly.Wait for 10 seconds for the turnstile to com-
plete the self-test program. At the same time, check if
the indicators work properly. If everything works fine,
you can fasten the ground screw nuts and fix the device.
If an exception occurs, please contact your vendor.
Debugging Functions
Operating instruction
1. After powered on, the LCD screen on the control board
will display the default state showing the current work-
ing mode.
2. There are 4 buttons on the control board:
UP: to move upwards or increase the value.
DOWN: to move downwards or decrease the value.
ENT: to enter a menu setting item or confirm the current
modified value.
ESC: to return to the previous menu or cancel the cur-
rent operation.
Menus
1. Position adjustment of the swing barrier
• Type: zero (default).
• Left limit, Right limit
2. Passing mode
• Opening mode: Two-way swipe (default)
• Left free, Right swipe
• Left swipe, Right free
• Two-way free
• Left prohibit, Right swipe
• Left swipe, Right prohibit
• Left prohibit, Right free
• Left free, Right prohibit
• Two-way prohibit
3. Opening duration (Press ‘ENT’ to modify)
After the gate is opened, it will automatically close
if no one passes through within a certain time du-
ration. The default value is 5 seconds. The value
ranges from 2 to 60.
4. Reverse intrusion
Mode: Close the door and voice alarm Voice alarm
only (default) .Turn off reverse detection
5. Trailing alarm detection
• Mode:Turn off trailing detection
• Voice alarm only (default)
• Close the door and voice alarm
6. Opening speed
Speed value: 1~20 (default 1)
7. Closing speed
Speed value: 1~20 (default 1)
8. Swiping mode
• Method: Allow the card to be swiped in the channel
(default).
• Do not allow card swiping in the channel
9. Reset counter
• Reset: Out counter (default)
• Into the counter
• All
10. Gate closing delay time
Time: 0~10 (default 0)
11. Brake unlock mode
Mode: Delay unlock (default)
12. Brake starting angle
Angle: 1~10 (default 3)
13. Fire alarm signal
• Signal: right open
• Left open (default)
• Shut down
14. Volume setting
• Volume: off
• The value ranges from 1 to 16 (default 5).
• 1 is the minimum value; 16 is the maximum value.
15. Audio prompt for gate opening swift
• Enable or not: No (default)
• Yes
16. Infrared anti-pinch
• Mode:Turn off the anti-pinch feature
• Enabling anti-pinch (default)
17. Infrared anti-pinch area
• Area selection:
• Disable during In and out of infrared (default)
• All infrared zone anti-pinch
18. Memory opening
• Whether to open: No (default)
• Yes
19. System working mode
• Mode: working mode (default)
• Test mode • Restore to factory
20. Version number:
Version:V9.0.0

WIRING DIAGRAM
Below is the wiring diagram:
© 2020 TimeTec Cloud Sdn Bhd. All rights reserved • 062020
DIMENSIONS
6
6
0
12
00
7
4
5
5
0
4
55
1
0
4
0
295
1600
1
020
TROUBLESHOOTING
No
1
2
3
4
Failure descriptions
The mode indica-
tor light does not
respond or the indi-
cation is incorrect.
After swiping the
card, there is only a
speed gate un-
locked.
The barrier doesn’t
close when the
opening delay time
is ended.
When the gate
is self-tested, the
swing arm is not in
the normal closing
position!
Analysis and solution
Check that the control
panel mode indicator wir-
ing is correct or that the
contact is poor.
Check the mode setting
of the master and slave
devices and the 8-core, 2-
core connection lines. See
the wiring diagram for the
specific connection circuit.
Check to see if the opening
delay time is too long or
whether the IR sensor is
covered.
In the process of self-test,
there are obstacles,please
remove the obstacles,
restart the self-test after
power-on!