manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Vicon
  6. •
  7. Card Reader
  8. •
  9. Vicon VAX-D3R-OSDP User manual

Vicon VAX-D3R-OSDP User manual

This Quick Start Guide is intended for experienced installing technicians. It is a basic reference to ensure all connections are properly
made. It is for models VAX-D3R-OSDP and VAX-D6.2R-OSDP Smartcard Readers as well as variants supporting most industry leading card and
tag technologies. For additional information please refer to Vicon's website www.vicon-security.com.
1.0 Introduction
A key component of a physical security electronic access control
system, a contactless smartcard card reader is based on RFID
technology. In operation it is capable of reading data stored on a
proximity credential via radio frequency and without physical contact,
and then passing the data obtained to the physical access control
system. Access control systems typically manage and record the
movement of individuals through a protected area, such as a
locked door.
2.0 Mounting Provisions
Each reader may be installed either indoors or outdoors. Mounting
option is shown in the table below. Use supplied #6 mounting screws,
or equivalent security screws, for installation.
Model
Mullion
Mount
VAX-D3R-OSDP •
VAX-D6.2R-OSDP •
3.0 Cable Requirements
Cable, 4 conductor, 22 or 24 AWG [65 mm or 51 mm] twisted pair,
over-all shield and UL approved (Belden 8273, or equivalent).
Maximum bus length: 4,000 ft – 24 AWG (1,219 m)
Maximum distance between: 1,640 ft – 24 AWG (500 m)
4.0 Reader Wiring
OSDP
Twisted Pair Conductor Function
Pair 1 Red DC (8-14 VDC)
Black Ground
Pair 2 Green RS-485 Tx+
White RS-485 Tx-
5.0 Output Formats
The SIA standard OSDP protocol is supported for clear and secure
channel communication.
Default Address: 0
Default Baud rate: 9600bps (bits per second)
Default Secure Channel Key:
SCBK_D = 0x303132333435363738393A3B3C3D3E3F.
OSDP Protocol Technical Support:
SIA OSDP Application Profile: Basic Reader (OSDP v2.2 and higher)
6.0 Grounding
Shield (drain) continuity must run from the reader to the access panel.
Shield (drain) and reader ground must be tied together at the access
panel and connect to an earth ground at one point.
7.0 Power
Reader may be powered by the access panel. A linear power supply is
recommended for best operation.
8.0 Voltage and Current
Voltage: 8 to 14 VDC
Current Draw: 135mA typical at 12 VDC
9.0 Read Mode
Reader (OSDP “PD”) operation is controlled by the access panel
(OSDP “ACU”) per the OSDP specification.
10.0 Connection
Connection must be done in accordance with NFPA 70. Do not
connect to a receptacle controlled by a switch. Connect to a power
limited DC voltage source.
11.0 Troubleshooting
1. When the reader is first powered on it will beep 4-times.
2. Presenting a supported access credential will result in the reader
beeping once.
3. OSDP communications with the panel will be established after the
reader has completed its start-up sequence. The panel can query
the reader for status using OSDP commands. Note, at this point,
the access panel controls the reader beeper and LED functionality.
See additional troubleshooting information on reverse side.
Quick Installation Guide
VAX-D3R-OSDP and VAX-D6.2R-OSDP Smartcard Readers with OSDP Support
XX274-26
If the reader does not recognize the card or tag (no beep, no LED
flash), refer to possibe OSDP communications errors detected at the
access control panel. Please see the table below for additional
possible causes and solutions.
Possible Cause Corrective Action
OSDP misconfiguration,
not configured for OSDP,
secure channel mismatch
Confirm panel is configured for
OSDP. Confirm panel and reader are
both configured for Secure Channel
(or both unencrypted.) Confirm PD
address and speed.
Incorrect cabling Verify gauge, connections and
cabling length. Verify RS-485 OSDP
connections (Tx+/Tx-)
Not enough power 12 VDC recommended, 8 VDC at
reader is minimum
Incorrect card used Verify panel has established OSDP
connection with reader, then verify
if card technology is supported
Reader/access panel not
properly grounded
Earth ground needed—verify shield
and reader ground are tied at access
panel and connect to ground at
one point
Supply generating
interference
Linear power supply recommended,
verify switching power supply
before use
Should any of the corrective actions mentioned above not improve
performance, disconnect the reader from the access panel and power
it with a separate power supply or 9 VDC battery, and re-test card
functionality, with an OSDP panel simulator if necessary. By powering
the readers separately, most variables that may lead to reduced
performance can be eliminated. OSDP issues often require a packet
trace, which the installer or panel vendor should be prepared to
provide if there are problems. Should the problem persist, please
contact Vicon Technical Support.
IP Rating: IP67
Many Vicon Readers carry the following certifications:
FCC Compliance Statement: This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by Vicon could void the
user's authority to operate the equipment.
Product can be used without license conditions or restrictions in all European Union
countries, including Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Spain,
Sweden, United Kingdom, as well as other non-EU countries, including Iceland,
Norway, and Switzerland.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference, including
interference that may cause unde-sired operation of the device.
Cet appareil est conforme à Industrie Canada exempts de licence standard RSS (s).
Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne
peut pas provoquer d’interférences et (2) ce dispositif doit accepter toute
interférence, y compris les interférences qui peuvent causer un mauvais
fonctionnement du dispositif.
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
For proper PIN security with keypad readers, please review
PIN Best Practices Reference Document.
QUICK START GUIDE
VAX-D3R-OSDP AND VAX-D6.2R-OSDP 13.56-MHz CONTACTLESS
SMARTCARD READERS WITH OSDP SUPPORT
P/N: 8009-8274-26-00
Vicon Industries Inc.
Tel: 631-952-2288
Toll Free: 800-645-9116
Fax: 631-951-2288
24-Hour Technical Support:
800-34-VICON (800-348-4266)
UK: 44/(0) 1489-566300
Product specifications are subject to
change without notice.
REV June 2021 www.vicon-security.com
©2021 Vicon Industries. All rights reserved. Vicon and its logo are registered
U.S. trademarks and VAX and its logo are trademarks of Vicon Industries Inc.
All other trademarks are the property of their respective owners.

This manual suits for next models

1

Other Vicon Card Reader manuals

Vicon VAX-PCR-35L User manual

Vicon

Vicon VAX-PCR-35L User manual

Vicon VAX-CR-35L User manual

Vicon

Vicon VAX-CR-35L User manual

Vicon VAX-D403R User manual

Vicon

Vicon VAX-D403R User manual

Vicon VAX-300R User manual

Vicon

Vicon VAX-300R User manual

Vicon DS-K182HP User manual

Vicon

Vicon DS-K182HP User manual

Vicon VAX-300R User manual

Vicon

Vicon VAX-300R User manual

Vicon VAX-300R User manual

Vicon

Vicon VAX-300R User manual

Vicon VAX-D3R User manual

Vicon

Vicon VAX-D3R User manual

Vicon VAX-D6.4R User manual

Vicon

Vicon VAX-D6.4R User manual

Vicon VAX-P403R User manual

Vicon

Vicon VAX-P403R User manual

Vicon VAX-D403R User manual

Vicon

Vicon VAX-D403R User manual

Popular Card Reader manuals by other brands

SICK Lector 620 Online help

SICK

SICK Lector 620 Online help

Lexar RW022 user manual

Lexar

Lexar RW022 user manual

ZKTeco Bio30R user manual

ZKTeco

ZKTeco Bio30R user manual

Siemens SIMATIC MV440 operating instructions

Siemens

Siemens SIMATIC MV440 operating instructions

Renkforce CR49e-Alu operating instructions

Renkforce

Renkforce CR49e-Alu operating instructions

HP Access Control install guide

HP

HP Access Control install guide

SpringCard K663-TTL quick start guide

SpringCard

SpringCard K663-TTL quick start guide

Winnix Technologies HYR6021A Instruction

Winnix Technologies

Winnix Technologies HYR6021A Instruction

MARKEM Cimjet RFID Operation & service manual

MARKEM

MARKEM Cimjet RFID Operation & service manual

UTC Fire and Security Interlogix ACL800DIN-RDRMF Installation sheet

UTC Fire and Security

UTC Fire and Security Interlogix ACL800DIN-RDRMF Installation sheet

IDTECH OMNI manual

IDTECH

IDTECH OMNI manual

Conlan PR 1000 user manual

Conlan

Conlan PR 1000 user manual

Assa Abloy SACURITRON Aperio DR100 Installation & operating instructions

Assa Abloy

Assa Abloy SACURITRON Aperio DR100 Installation & operating instructions

Uniform Industrial HCR350-C Series Simple manual

Uniform Industrial

Uniform Industrial HCR350-C Series Simple manual

NESS ID TECK IPK101 user manual

NESS ID TECK

NESS ID TECK IPK101 user manual

Logic Controls MR1000 Specifications

Logic Controls

Logic Controls MR1000 Specifications

Paxton ZKTeco SpeedFace Reader SF1008+ quick start guide

Paxton

Paxton ZKTeco SpeedFace Reader SF1008+ quick start guide

Hama 00181020 operating instructions

Hama

Hama 00181020 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.