INSTALLATION MANUAL
ECO 20 Automatic Regulation of Burning
1
ECO 20 INSTALLATION MANUAL
Step 1 Install the Exhaust Temperature Sensor
Note: The exhaust temperature sensor is the one with the green cable.
•Drill a hole in the exhaust pipe about 150 mm beyond where it exits the
stove. The proper-sized drill bit (Ø 6.3 mm) is included.
•Slide the thermal sensor into the holder so that the sensing tip extends
about as far as half the exhaust pipe’s diameter. On the most common
exhaust pipe diameter of 150 mm, this would have the sensing tip
protrude about 75 mm past the holder (and, therefore, about this same
distance into the pipe once mounted). Carefully bolt the sensor into
place.
•Drill two more holes into the exhaust pipe, in positions matching the
sensor holder’s mounting holes when the sensing tip is inserted in the
first hole. The proper-sized drill bit (Ø 2.5 mm) is included. Screw the
holder into place using the two included screws.
•Lead the connector-tipped cable to where the control unit will be
mounted. (The control unit is located on the shutter.) Make sure the
cable does not touch any parts of the stove that become hot when in
use.
If you need to shorten the thermal sensor assembly, never do so by cutting pieces off the
metal part of the sensor. The silicon cable can be cut down to any length you need.