TIS Mars 4 gangs User manual

MARS 4 GANGS WALL PANEL
INSTALLATION MANUAL
With its elegant shape and design, the Mars
Series is available in seven different colors with
stylish push buttons. This capability is of great
value to elderly people because they can enjoy a
combination of classic and new technology.
Automation Made Easy
Model: MRS-4G
PRODUCT INFORMATION
6 58921 79763 1
BARCODE (UPC-A)
PRODUCT SPECIFICATIONS
Input IR receiver TIS Infrared code receiver
Using Panel Addition 2-3 Digital Inputs
Output
Using Panel Addition 3R 3 Relay Output 3A/5A
Using Panel Addition 3DL-12V 12V DC 50mA Output
Using Panel Addition 2DL-IRE IR Emitter
TIS Bus
Number of devices on 1 line Max. 64
Bus voltage 12-32 V DC
Current consumption <35 mA / 24 V DC
Operating and
display elements
8/4 Buttons
For controlling lights, scene, etc…
Indicator LED
4 Blue and Orange LED
Backlight
2 pairs of White neon LED
TIS bus
TIS Protocol messages and commands
Upgrading
1 X mini USB for up to date upgrading.
Functions
1 Press ON / OFF / Scene
Long Press Dim or ramp the lights
Double click Extra Scene
IR receiver Music, scene, lights control
Dimensions Width × length × height 90mm × 125mm × 15mm (21mm peak)
Housing
Materials PC anti fire
Casing color Black, Titanium, Silver, White, Champaign,
Coal, Bronze or special color
Internal Parts color Black & White
IP rating IP 30

2
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
Data Cable
Use screened stranded RS485 data cable
with four twisted pairs. Congure devices in
a “Daisy Chain.”
Do not cut or terminate live data cables.
Electrical Wires
The recommended wire size for light
channels is 2.5mm for loads, if you are
using the Panel Addition 3R type. The
installer should consider the total current
consumption when selecting the wires.
Warranty
There is a two-year warranty provided
by law. The hologram warranty seal and
product serial number are available on
each device.
Read Instructions
We recommend that you read this
Instruction Manual before installation.
Safety instructions
Electrical equipment should only be
installed and tted by electrically skilled
persons.
Failure to observe the instructions may
cause damage to the device and other
hazards.
These instructions are an integral part of
the product and must remain with the end
customer.
Programming
This device can be tested and programmed
manually. Advanced programming
requires knowledge of the TIS Device
Search software and instruction in the TIS
advanced training courses.
Simple Installation
You can use 2 screws to install this panel
on wall, it t on most of junction box sizes.
Mounting Location
Install in a dry, indoor area. with a suitable
temperature and humidity range.

3
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
Insert a large athead screwdriver in
the hole of the Panel Cover. Rotate the
screwdriver 90 degrees.
1
INSTALLATION STEPS
2Separate the Cover, Main Panel, and
Wall Base from each other.

4
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
Remove the 2 screws on the Panel
Addition cover.
3
INSTALLATION STEPS
4
Smart Home
Smart Home
Connect the Wall Base and Panel
Addition in this position. Place the upper
pins as shown, and then push the down
pins down with your ngers to assemble.

5
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
It should look like this following the
correct assembly.
INSTALLATION STEPS
5
6
Turn off the main electrical source before
installation.
Connect the Cat5e TIS BUS wire to the
Panel Addition.
PANEL ADDITION
TIS BUS Input : 75-45mA/24V DC
Output Current : 3A220VAC
COM OUT3 OUT2 OUT1 COM
www.tissmarthome.com
D- 24+V
GND D+
To the TIS BUS Network
Cat5e
Mars 4G
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
WARNING! HIGH VOLTAGE

6
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
low voltage cable
low voltage cable
low voltage cable
PANEL ADDITION
2 Digital Input with IR Receiver
Model : ADD-2DL-IRR
TIS BUS Input : 45mA/24V DC
VCC REC GND Z2 Z1
www.tissmarthome.com
D- +24V
GND D+
TIS IR Receiver probe
To the TIS BUS Network
Cat5e
Mars 4G
PANEL ADDITION
2 Digital Input with IR Receiver
Model : ADD-2DL-IRR
TIS BUS Input : 45mA/24V DC
VCC REC GND Z2 Z1
www.tissmarthome.com
D- +24V
GND D+
To the TIS BUS Network
Cat5e
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5econnection
low voltage cable
low voltage cable
Traditional Switch
L
S2
S1
S1
L
L
S2
INSTALLATION STEPS
7Connect the other connection if needed as per the panel addition type.
FOR PANEL ADDITION 2DL-IRR
You can connect 2 digital inputs to any
switch or window magnet.
You can add an External Infrared Receiver
to the IRR Port, connect as follows:
▸
the IR Receiver black wire to GND
▸
Gray wire to REC
▸
Red wire to VCC Terminal.

7
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
Cat5e connection
+24V(brown-orange)
D+(blue-green)
low voltage cable
low voltage cable
PANEL ADDITION
2 Digital Input with IR Emitter
Model : ADD-2DL-IRE
TIS BUS Input : 45mA/24V DC
IR- IR+ GND Z2 Z1
www.tissmarthome.com
D- +24V
GND D+
TIS IR Emitter probe
To the TIS BUS Network
Cat5e
Mars 4G
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
low voltage cable
low voltage cable
PANEL ADDITION
2 Digital Input with IR Emitter
Model : ADD-2DL-IRE
TIS BUS Input : 45mA/24V DC
IR- IR+ GND Z2 Z1
www.tissmarthome.com
D- +24V
GND D+
Door Magnet Contact
To the TIS BUS Network
Cat5e
Mars 4G
INSTALLATION STEPS
FOR PANEL ADDITION 2DL-IRE
You can connect 2 digital inputs to any
switch or window magnet.
▸
Connect the IR Emitter Probe’s positive
wire to IR+ terminal.
▸
Connect the negative wire to IR-terminal.

8
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
low voltage cable
low voltage cable
low voltage cable
PANEL ADDITION
3 Digital Input with 12V Output
Model : ADD-3DL-12V
TIS BUS Input : 45mA/24V DC
+12V GND Z3 Z2 Z1
www.tissmarthome.com
Output: DC 12V/50mA
D- +24V
GND D+
C5
C2
PULSE
1&2
2&3
NONE
1P
2P
3P
RELAY
1&2
2&3
NO
NC
1 2 3
RELAY
1&2
2&3
NO
NC
1 2 3
TAMPER
ALARM
12V GND
CON1
1 2 3
LED1
818-6B V2.3
2016-11-09
To the TIS BUS Network
Cat5e
Mars 4G
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
low voltage cable
low voltage cable
PANEL ADDITION
3 Digital Input with 12V Output
Model : ADD-3DL-12V
TIS BUS Input : 45mA/24V DC
+12V GND Z3 Z2 Z1
www.tissmarthome.com
Output: DC 12V/50mA
D- +24V
GND D+
Door Magnet Contact
To the TIS BUS Network
Cat5e
Mars 4G
INSTALLATION STEPS
FOR PANEL ADDITION 3DL-12V
You can connect 3 digital inputs to any
switch or window magnet.
Also, you can connect any 12V operated
smoke detector or any 3rd party sensor
with NC/NO connection to the 12V GND
and Z1-Z3 terminals as per the diagram.

9
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
24+V(brown-orange)
Cat
5e connection
1.5 mm Electric Cable
1.5 mm Electric Cable
2.5 mm Electric Cable
PANELADDITION
3OutputRelay 5 Amp
Model: ADD3-R5-A
TISBUS Input : 75-45mA/24V DC
OutputCurrent : 3A220VAC
COM OUT3 OUT2 OUT1 COM
www.tissmarthome.com
D- 24+V
GND D+
Connect To L
O-OFF
I-ON
MCB
Open
Close
220 ~ 110
Volt
Connect To N
To the TIS BUS Network
Cat5e
Mars 4G
PANEL ADDITION
3Output Relay 5 Amp
Model: ADD-3R-5A
TISBUS Input : 45-75mA/24V DC
OutputCurrent : 3A220VAC
COM OUT3 OUT2 OUT1 COM
www.tissmarthome.com
D- +24V
GND D+
To the TIS BUS Network
Cat5e
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
1.5 mm Electric Cable
1.5 mm Electric Cable
2.5 mm Electric Cable
Connect To L
O-OFF
I-ON
MCB
Connect To N
Mars 4G
INSTALLATION STEPS
LIGHTING CONNECTION
▸
Connect the live wire to com
▸
Connect the loads wire to Out1-Out3
to terminals
▸
Connect load neutral wire to main
neutral in the distributor box.
CURTAIN CONNECTION
▸
Connect the Supply wire to COM
▸
Connect the Open wire to OUT1
▸
Connect the Close wire to OUT2
▸
Shutter neutral connection, if it exists,
can be looped to main neutral in the
distributor box.
FOR PANEL ADDITION 3R-5A
WARNING: Set the curtain function in the
software before connecting the wires.

10
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
1.5 mm Electric Cable
2.5 mm Electric Cable
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
COOL
HEAT
FAN
COM
PANELADDITION
3 Output Relay 5 Amp
Model : ADD-3R-5A
TIS BUS Input : 45-75mA/24V DC
Output Current : 3A220VAC
COM OUT3 OUT2 OUT1 COM
www.tissmarthome.com
D- +24V
GND D+
To the TIS BUS Network
Cat5e
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
24+V(brown-orange)
Cat5e connection
1.5 mm Electric Cable
1.5 mm Electric Cable
2.5
mm Electric Cable
PANELADDITION
3Output Relay 5 Amp
Model: ADD3-R5-A
TISBUS Input : 75-45mA/24V DC
OutputCurrent : 3A220VAC
COM OUT3 OUT2 OUT1 COM
www.tissmarthome.com
D- 24+V
GND D+
Connect To L
O-OFF
I-ON
MCB
LOW
MEDIUM
HIGH
To the TIS BUS Network
Cat5e
Mars 4G
INSTALLATION STEPS
FCU CONNECTION
▸
Connect the supply wire to com
▸
Connect the FAN Low, Medium, and
High wires to Out1, Out2, and Out3 in
the same order.
HVAC CONNECTION
▸
Connect the HVAC com (supply) wire
to com
▸
Connect the Cool, Heat, and FAN
wires to Out1, Out2, and Out3 in the
same order.
FOR PANEL ADDITION 3R-5A
WARNING: Set the FCU function in the
software before connecting the wires.
WARNING: Set the HVAC function in the
software before connecting the wires.

11
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
1.5 mm Electric Cable
1.5 mm Electric Cable
O-OFF
I-ON
MCB
Connect To L
Connect To N
TIS AIR BUS Convertor
Model NO : TIS-AIR-BUS-3W
AC Input : 100~240 V AC
www.tissmarthome.com
TIS AIR
TIS BUS Output : 100mA/12 V DC
D- +24V
GND D+
N L
INSTALLATION STEPS
FOR PANEL ADDITION AIR-BUS-3W
▸
Connect the live wire to the L terminal,
▸
Connect the neutral wire to N terminal.
Mount the device on the wall using 2
screws on the junction box.
8

12
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
INSTALLATION STEPS
Connect the main Mars panel vertically to
the other part installed in the wall.
10
Pull by your ngers this Protective
Plastic Cover vertically, remove it and
throw it.
9

13
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
INSTALLATION STEPS
Install the 2 black screws to x the Mars
panel to the wall base.
Install the Mars Cover on the panel.
Turn on the power source. The panel
should turn ON.
11
12
13

14
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
PAIRING (MANUAL PROGRAMMING)
RCU80-UT8-IN WARNING! HIGH VOLTAGE!
TIS-BUS
GND D- D+ 24+V
PRG
1 2 3 4 5 678
1 2 3 4 5 678
-+
8
7
GND
6
54
32
10-0V
DIGITAL INPUT
GND
1
6”
LIGHTS / SHUTTERS PROGRAMMING
You can pair the light channels with any wall panel. To do so, follow these steps:
1Press any button on any channel of a
relay or dimmer module for 6 seconds so
that the LED indicator light of that button
starts blinking.
Shortly press on any button on wall panel
or press the wall switch that connected
to dry inputs of the panel addition zones.
2
Test the button on the panel by short
pressing it for ON/OFF and long pressing
it to dim (if channel is dimmable).
3

15
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
PAIRING (MANUAL PROGRAMMING)
SCENARIO PROGRAMMING
The last row of the Panel button (Button 4) can be programmed as a mood (scene) that
can save the other 3 buttons’ statuses.
1Use the rst 3 buttons to set your lights to
ON/OFF or dim brightness level, shutter
status, etc., as per your desired mode
(scene)
Long press button 4 for 12 seconds until
its LED blinks RED.
2
The scene is programmed; you can test it
by single press on button 4.
3
12”

16
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
USER MANUAL
You can use the panel buttons 1-4; press on any button to get the settings that you
programmed.
▸
Short press for ON/OFF or to run a
scene.
▸
Double click to trigger a special
programmed scene.
▸
Long press to dim or ramp up the lights.
USING THE PANEL
×2

17
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
You can use TIS’s IR Remote Control to
run programmed buttons 1-4. You can
also set the music audio player address
on the Mars and play music using the
Remote Control.
USER MANUAL
TIS-MRC REMOTE CONTROL
▸
You can enable or disable the white
backlight, and you can set the LED
status color from blue to red.

18
INSTALLATION MANUAL
MODEL: MRS-4G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
MARS 4 GANGS WALL PANEL
TROUBLESHOOTING
The Panel backlit white LEDs
blinks rapidly.
Reason: The panel address conicts with
another device in the TIS network. You need
to press and hold any button for 6 seconds
so the panel can get a new address.
The panel buttons’ LEDs do not
turn ON, and the device is not
powered.
Reason 1: There is no TIS-BUS power or no
connection to the L/N input (if using AIR bus-
3W converter).
Reason 2: The TIS 24V power supply is not
connected to the TIS-BUS.
Wall panels fail to pair with
other devices.
Reason 1: The TIS-BUS connection has a
problem, or the wire has a short.
Reason 2: The manual programming
function is disabled on the device (it is
enabled by default).
Wall panels fail to control the
device channels.
Reason 1: The TIS-BUS connection has a
problem, or the wire has a short.
Reason 2: The programming address is
faulty.
This manual suits for next models
1
Table of contents
Other TIS Thermostat manuals
Popular Thermostat manuals by other brands

Anova
Anova Precision Cooker WI-FI user manual

Siemens
Siemens Powers TH 192 S Technical instructions

Hunter
Hunter 40170 Installation and operation manual

Crestron
Crestron infiNET EX CHV-TSTATEX-FCU quick start guide

SierraLingo
SierraLingo SL-EOS-1100 user manual

Cool Solutions
Cool Solutions COOLSPACE/EnTouch Pro user guide