TKH Security | Siqura UP Series | Installation manual v3.0 2
Note: To ensure proper operation, please read this manual thoroughly before
using the product and retain the information for future reference.
UPxx Series
Installation Manual v3.0. (Added UP36D)
Nothing from this publication may be copied, translated, reproduced, and/or published by
means of printing, photocopying, or by any other means without the prior written
permission of TKH Security.
TKH Security reserves the right to modify specifications stated in this manual.
Brand names
Any brand names mentioned in this manual are registered trademarks of their respective
owners.
Liability
TKH Security accepts no liability for claims from third parties arising from improper use
other than that stated in this manual.
Although considerable care has been taken to ensure a correct and suitably
comprehensive description of all relevant product components, this manual may
nonetheless contain errors and inaccuracies. We invite you to offer your suggestions and
comments by email via info@tkhsecurity.com Your feedback will help us to further improve
our documentation.
How to contact us
If you have any comments or queries concerning any aspect related to the product, do not
hesitate to contact:
TKH Security B.V.
Meridiaan 32
2801 DA Gouda

TKH
TKH Security | Siqura UP Series | Installation manual v3.0 3
Contents
Contents .............................................................................................................................3
Important Safety Instructions...............................................................................................4
Description & Models..........................................................................................................6
Installation & Connections...................................................................................................7
Installing the washer nozzle..............................................................................................14
Maintenance .....................................................................................................................15

TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura UP Series | Installation manual v3.0 4
Important Safety Instructions
Prior to installation and operation, carefully read all instructions the in this
manual and heed all warnings.
Unpack this equipment and handle it carefully. If the package appears to be
damaged, notify the shipper immediately.
Use the original packaging to transport the unit. Disconnect power supply
before moving it. In case of returning the equipment, the original packaging
must be used.
Make sure that the installation surface can support at least four times the
weight of the unit in normal operating conditions. In case of excessive
external stress (e.g. vibration, strong winds or impact), the equipment may
need additional means of protection.
Proper hardware should be carefully chosen to fasten the unit to the
surfaces.
Use caution when lifting and assembling the unit. It is recommended that
non-slip protective gloves be worn during installation. The unit could bear
sharp edges.
Trying to manually force the wiper will result in damaging the device and will
void the warranty.
To maintain the IP rating of the unit, adequate cable glands must be used.
The unit must be tightly closed when operating.
For security reasons, do not install the unit in the proximity of water
containers and never push objects or pour liquids into the unit. The unit can
be safely used in damp environments or outdoors, as long as the connectors
and lids are properly sealed.
Video and data cables should not share the same conduit with supply voltage
cables. Whenever EMC is an issue, adequately shielded cables must be
used.
Open only the covers pointed out in this installation manual. Other covers
should be open only by the manufacturer.
This equipment has been designed to operate in harsh environments
requiring little or no maintenance. Suggested inspection interval is 6 months,
but extremely harsh environments may require more frequent inspection and
maintenance checks. On each inspection check the O-ring seals and the
eventual window wiper blade integrity. Replace them if necessary.
Check cables, electrical connections and mounting hardware for integrity and
tightness. Replace or tighten any damaged/loose part.
Before performing any operation, turn off the power. The installation of the
unit can be performed only by qualified personnel in accordance with the
regulations in force. Do not connect the unit to a supply circuit unless the
installation is completed.
Power the unit with 24 Vac / 3 A (75 W) power supply. Incorrect Power
Supply Voltage may damage the unit. Do not overload the terminal
connection, as it may cause a fire or electrical shock hazard.

TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura UP Series | Installation manual v3.0 5
An all-pole mains switch with an opening distance between the contacts at
least 3 mm in each pole must be incorporated in the electrical installation.
The switch must be equipped with protection against the fault current towards
the ground (differential) and the overcurrent (magnetothermal, maximum
15A). It must be very quickly recognizable and readily accessible. A suitable
blow fuse must also be installed for protection.
Fasten all the cables with cables ties or similar to avoid the electrical contact
with surrounding parts in case that terminal blocks screw off.
Electrical connections (such as plugs and cords) must be protected from
potential hazardous environmental factors (e.g. foot traffic, hitting objects).
Ensure that the unit case is properly earthed, connecting all the earth ground
studs. Earth cable should be about 10mm longer than the other cables on the
connector, in such way that it won't be accidentally disconnected if the cable
is stretched or pulled.
When leaving the unit unused for long periods, disconnect supply cables.

TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura UP Series | Installation manual v3.0 6
Description & Models
The Upright PTZ (UP33, UP36 or UP36D) is a high-precision, full-featured network PTZ
camera that delivers high quality, high-definition images. The rugged construction of cast
aluminum and durable plastic ensures accurate positioning and stable video, both close up
and long distance. The UP is designed to operate in extreme temperatures for mission-
critical applications. It is tested and approved to the to the environmental requirements of
NEMA TS-2. And its powder-coated aluminum construction complies Corrosion Class C5.
Models
UP33 - Upright PTZ, 33x zoom, 24 Vac
UP36 - Upright PTZ, 36x zoom, 24 Vac
UP36D - Upright PTZ, Dual sensor 36x zoom, 24 Vac
UP…-PoE - Upright PTZ suitable for PoE++ only
UP-IR200 - IR illumination kit for Upxx, 200m, 25°, 850 nm

TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura UP Series | Installation manual v3.0 7
Installation & Connections
Overview
1. Sunshield
2. Wiper
3. Main body
4. Base housing
5. Zoombox camera
6. Telemetry card
1. Washer control
2. Not connected
3. Ethernet (RJ45)
4. 2x2 wire for camera and
IR power

TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura UP Series | Installation manual v3.0 8
Installing the optional IR Illuminator (UP-IR200)
1. Secure the bracket to the camera with the 3 supplied bolts.
2. Connect the IR illuminators to the brackets. Lead the IR illuminator cable into the
housing through the cable-clamps in the bracket and insert it in the housing through the
cable-gland at the back of the housing.
3. Connect the IR-illuminator power cables to the telemetry board.
Cabl
Cable

TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura UP Series | Installation manual v3.0 9
4. Set SW1-8 to the OFF position. Both UP33 and
UP36 controls the illuminators by Aux2.
SW1 should be in the following position:
1.
ON
Reserved
2.
ON
Reserved
3.
OFF
Reserved
4.
OFF
Reserved
5.
OFF
Reserved
6.
OFF
Reserved
7.
OFF
Reserved
8.
OFF
Camera (Aux2) control
5. Remove the blind plug on the backside of the IR-
illuminator to access the control DIP switch.
Slide the 3rd switch to ON.
(In case there is no DIP switch, no special action
is required)

TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura UP Series | Installation manual v3.0 10
Mounting with the optional wall bracket (UP-WM)
1. Fix the wallmount bracket (UP-WM) using sturdy anchor bolts. Each bolt should be able
to hold at least 60 kg. (M10x30 is recommended)
2. Remove the rectangle shaped base-plate from the base housing and replace it with the
wallmount adapter plate (part of the UP-WM delivery).
3. Mount the UP33 or UP36 on the wallmount bracket. Lead the multicable tail through the
cable tray of the bracket.
4. Reassemble the cover of the wallmount bracket.

TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura UP Series | Installation manual v3.0 11
Mounting with the optional junction box (UP-JB)
1. Remove the rectangle shaped base-plate from the base housing and replace it with the
top part of the junction box.
2. Mount the base plate of the UP-JB to the pole top or the UP-WM.
3. Mount the camera carefully on the UP-JB base plate
4. Make the connections to the UP cable tail inside the UP-JB and close the UP-JB lid..

TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura UP Series | Installation manual v3.0 12
Connections
(1) Washer control
The washer control is connected by the ALARM-out wires.
Cable Label
Cable color
Remarks
ALARM IN
Black
GND
Brown
ALARM OUT NO
Red
Normally open (Washer)
ALARM OUT NC
Orange
Normally closed
ALARM OUT COM
Yellow
Common (Washer)
1. Washer control
2. Not connected
3. Ethernet (RJ45)
4. 2x2 wire for camera and IR
power
UP33/UP36
WP10 Washer tank
Mains
power
24Vac
power

TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura UP Series | Installation manual v3.0 13
(3) Ethernet
Ethernet cable should be CAT5e terminated with a RJ45. The max distance is 100m.
The RJ45 connection can be made waterproof (IP66) by using the “RJ45 water proof
accessory”, which is standard included.
Assemble the water proof RJ45 as shown in the drawing below..
(4) Power supply
Cable Label
Cable Colour
Input
Main power
Brown
24 Vac, 4 A, 50/60 Hz
Blue
IR Illuminator power
Black
24 Vac, 6A, 50/60 Hz
Green
Recommend power supply wire specification:
Wire type
AWG16
AWG14
Max cable length
15m
24m

TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura UP Series | Installation manual v3.0 14
Installing the washer nozzle
The bracket for the nozzle has to be installed separately. Please, follow the instructions
below:
1. Remove the rectangle shaped base-plate from the base housing.
2. Place the nozzle bracket between the base plate and the base housing at the position
of the small notch indicating the 0position. The nozzle bracket is of the delivery of the
WP10 washer tank.
3. Replace the rectangle base plate or proceed with fixing the UP-WM wall mount bracket.
4. For the UP33 only:
Define a washer position by setting one of the presets to P=0,T= 90. The camera has
to move to this preset before the washer is activated. (The wipe/washer are supported
by VDG Sense using the “onvif” driver)
5. The UP36D only
To protect the Germanium window, the UP36D is not equipped with a wiper.

TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura UP Series | Installation manual v3.0 15
Maintenance
To keep the UP PTZ camera in perfect condition over its life time, regular inspection and
cleaning of the camera is recommended. Depending on the severity of contamination of the
environment, the camera should be inspected and cleaned every 3 to 12 months.
Please follow the maintenance instructions below:
1. The camera can be cleaned using water jets with clean water (max. 1 Bar / 15 PSI @
3m) or by wiping the camera housing with a damp cotton cloth.
2. Remove nests of insects with an suitable brush. (Do not use chemicals)
3. Clean the optical glass window and the germanium window with lukewarm soapy water.
Use a soft cotton cloth to avoid scratching the windows or damaging its coating.
4. Check the condition of the wiper and replace if necessary. If the camera is in direct
sunlight it is recommended to replace the wiper with the original UP wiper at least once
a year.
5. Check the integrity of all the O-rings and rubber sealings. Lubricate them with silicone
grease (O-ring grease) to prevent them from getting drying out and to ensure their
watertightness. Replace the sealings if necessary.
6. It is recommended that the fan in the top housing is replaced every two years.
For replacement parts, please, contact TKH Security.