TKH Siqura VBS 2010 TX User manual

VBS 2010 TX
Optical video baseband transmitter
USER MANUAL
1. General description
The VBS 2010 TX analogue optical video baseband
transmitter converts a composite video signal into
an optical equivalent. Signal integrity is preserved
with the aid of video clamping.
The VBS 2010 TX utilises an optical wavelength of
850 nm and needs multimode optical fiber.
The 7TE modules are to be used in combination
with TKH Security's MC 10 or MC 11 power
supply cabinets.
Using TKH Security’s ADV units, the signal
transmitted by these plug-in modules can in
addition to video comprise two data signals, still
using only one optical fiber.
2. Indicators and connectors
Figure 1 shows the signal connection facilities and
indicators on the front panel of a VBS 2010 TX
single-channel transmitter (see also table 1).
o
(ST connector)
optical output
o
(75 BNC connector)
video input
Status indicator LEDs
* DC (green)
DC power supply
* NV (red)
No video at input
Table 1. Front panel indications and connectors on the
VBS 2010 TX
3. Installation instructions
1. Plug the module into a power cabinet and
connect optical fiber equipment and video
equipment to the module: optical cord to the output
and video lead to the input (figure 1 and table 1).
2. After switching on the cabinet, at least the green
DC LED must glow.
3. On feeding the TX video input with a proper
signal, the NV LED (red) should go out.
4. Care and maintenance
In order to maintain reliable operation of the
module, observe the following:
- Prevent dust from collecting on the equipment
- Protect the equipment against moisture
- Maintain sufficient free space around the equip-
ment for cooling.
General safety and EMC information is found in the
final section of this document.
Figure 1.
Front panel layout of VBS 2010 TX
transmitters
© Siqura 2017
Version 992112-2f
VBS2010TX (MW10)
DC
TX
VBS
NV

2
5. Technical specifications
The technical specifications of VBS 2010 TX
transmitters are outlined in table 2 below.
Optical
Wavelength
850
nm
Source
LED
Fiber type
m
Output level1, MM
-18 (-22)
dBm
System link budget1,2
16 (12)
dB
Video
Video system
PAL/SECAM/NTSC
Input impedance
75
Return loss
30
dB
Input level
1
VPP
Environmental
Ambient temperature
full performance
+5 to +45
oC
operating
-40 to +74
oC
Relative humidity
<95 (no condensation)
%
Electrical safety
AL / IEC / EN 60950-1
UL recognition file
E242498
Laser safety
IEC 60825-1, IEC 60825-2
EMC immunity
EN 55024, EN 50130-4,
EN 61000-6-2
EMC emission
EN 55022 (Class B)
FCC 47 CFR 15 (Class B)
EMC
EN50081-1, EN50082-1
Electrical
Power supply voltage
±15.0
Vdc
Power consumption
0.5
W
Mechanical
Optical connector
ST
Video connector
BNC
Outer dims. (hxwxd)
128 x 35 x 190
mm
Weight (approx.)
450
g
1Using 62.5 (50/125) m fiber
2In combination with corresponding VBS RX receivers
Table 2. Technical specifications of VBS 2010 TX
modular transmitters
6. Safety, EMC, ESD
General
The safety information contained in this section, and on
other pages of this manual, must be observed whenever this
unit is operated, serviced, or repaired. Failure to comply with
any precaution, warning, or instruction noted in the manual
is in violation of the standards of design, manufacture, and
intended use of the unit.
Installation, adjustment, maintenance and repair of this
equipment are to be performed by trained personnel aware of
the hazards involved. For correct and safe use of the
equipment and in order to keep the equipment in a safe
condition, it is essential that both operating and servicing
personnel follow standard safety procedures in addition to the
safety precautions and warnings specified in this manual, and
that this unit be installed in locations accessible to trained
service personnel only.
Siqura assumes no liability for the customer’s failure to
comply with any of these safety requirements.
UL/IEC/EN 60950-1: General safety requirements
The equipment described in this manual has been
designed and tested according to the UL/IEC/EN 60950-1
safety requirements.
If there is any doubt regarding the safety of the equipment, do
not put it into operation. This might be the case when the
equipment shows physical damage or is stressed beyond
tolerable limits (e.g. during storage and transportation).
Before opening the equipment, disconnect it from all power
sources. The equipment must be powered by a SELV*) power
supply.
When this unit is operated in extremely elevated temperature
conditions, it is possible for internal and external metal
surfaces to become extremely hot.
Optical safety
This optical equipment contains Class 1M lasers or LEDs
and has been designed and tested to meet IEC 60825-
1:1993+A1+A2 and IEC 60825-2:2004 safety class 1M
requirements.
Optical equipment presents potential hazards to testing and
servicing personnel owing to high levels of optical radiation.
When using magnifying optical instruments, avoid looking
directly into the output of an operating transmitter or into the
end of a fiber connected to an operating transmitter, or there
will be a risk of permanent eye damage.Precautions should
be taken to prevent exposure to optical radiation when the
unit is removed from its enclosure or when the fiber is
disconnected from the unit. The optical radiation is invisible
to the eye.
Use of controls or adjustments or procedures other than
those specified herein may result in hazardous radiation
exposure.
The installer is responsible for ensuring that the label
depicted below (background: yellow; border and text: black)
is present in the restricted locations where this equipment is
installed.
The locations of all optical connections are listed in the
Indications and Connectors section of this manual.
Optical outputs and wavelengths are listed in the Technical
Specifications section of this manual.
Opt. input level (dB)
SNR (dB, weighted)
40
50
60
70
-40-35-30-25-20
Hazard Level 1M
Figure 2.
Typical video signal to noise ratio of VBS 20x0 systems
(850 nm, 50
m optical fiber).

3
EMC
Warning: Operation of this equipment in a residential
environment could cause radio interference.
This device has been tested and found to meet the CE
regulations relating to EMC and complies with the limits
for a Class A device, pursuant to Part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This
device must accept any interference received, including
interference that may cause undesired operation. These limits
are designed to provide reasonable protection against
interference to radio communications in any installation. The
equipment generates, uses, and can radiate radio frequency
energy; improper use or special circumstances may cause
interference to other equipment or a performance decrease
due to interference radiated by other equipment. In such
cases, the user will have to take appropriate measures to
reduce such interactions between this and other equipment.
Note that the warning above does not apply to TKH Security
products which comply with the limits for a Class B device.
For product-specific details, refer to the EU Declaration of
Conformity.
Any interruption of the shielding inside or outside the
equipment could make the equipment more prone to fail EMC
requirements.
To ensure EMC compliance of the equipment, use shielded
cables for all signal cables including Ethernet, such as
CAT5E SF/UTP or better, as defined in ISO IEC 11801. For
power cables, unshielded three wire cable (2p + PE) is
acceptable Ensure that all electrically connected components
are carefully earthed and protected against surges (high
voltage transients caused by switching or lightning).
ESD
Electrostatic discharge (ESD) can damage or destroy
electronic components. Proper precautions should be
taken against ESD when opening the equipment.
*) SELV: conforming to IEC 60950-1, <60 Vdc output, output
voltage galvanically isolated from mains. All power supplies or
power supply cabinets available from Siqura comply with these
SELV requirements.
7. Product disposal
Recycling The unit contains valuable materials which
qualify for recycling. In the interest of
protecting the natural environment, properly
recycling the unit at the end of its service life
is imperative.
8. EU Declaration of Conformity
The EU Declaration of Conformity for this product is
available at http://www.tkhsecurity.com/support-files