TMS LC-18-OD-4CH-48V User manual

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
________________________________________________________
________________________________________________________
LC-18-OD-4CH-48V
Lighting Controller Unit
(Overdrive)
USER MANUAL

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
1
Table of Contents
Hardware ................................................................................................................................................2
Packing List..........................................................................................................................................2
General Description ................................................................................................................................3
Specification........................................................................................................................................3
Connectors Description...........................................................................................................................4
Operation Mode .....................................................................................................................................7
Strobe Mode .......................................................................................................................................7
Current Multiplier ...................................................................................................................................8
LC-18 Software........................................................................................................................................9
Change IP Address.................................................................................................................................11
Slave Board Address Setting .................................................................................................................12
Communication Connection .............................................................................................................13
Input Signal ...........................................................................................................................................14
Output Signal ........................................................................................................................................14
Accessories............................................................................................................................................15
24V Power Supply.............................................................................................................................15
48V Power Supply.............................................................................................................................16
Cable Selection..................................................................................................................................17
Cable Information .................................................................................................................................18
Power Cord Information .......................................................................................................................19
Drawing Dimension...............................................................................................................................20
Communication Protocol......................................................................................................................22
Revision Notes
Rev
Date/Author
Comment
1.0
July2020/KW
First Revision
1.1
Aug2020/KW
Update X2 Version
1.2
Aug2020/KW
Added Communication Protocol Documentation

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
2
Hardware
Packing List
Please ensure the following items are in the package:
LC-18-OD-4CH-48V Controller Package
LC-18-M
LC-18-OD-4CH-X-48V
Ethernet Cable x1
RS232 Cable x1
Communication Cable x1set
24V Power Supply (Optional)
48V Power Supply (Optional)
Lighting Cable x 4pcs (Optional)
User Manual x1
User Interface (download from the link below)
Link for user interface and user manual from TMS LITE website:

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
3
General Description
The LC-18-OD-4CH-48V controller provides high current short interval strobing for
applications that require high intensity and high precision. The controller consists of 4 channels
with individual settings for each channel. Only Strobe mode is available for this controller.
Specification
Parameter
Value
Controller Supply Voltage
LC-18-M = 24 VDC
LC-18-OD-4CH-X-48V = 48 VDC
Lighting Supply Voltage
48 VDC
No. of Channel
4
Channel Mode
Strobe mode only
Output Current
Maximum current per channel
X1 = 1A
X2 = 2A
.
.
Xn = nA
Strobe Delay,
Output Delay,
Output Width
Adjustable 0 –99.99ms (10us/step)
Strobe Width
Adjustable 0 –10.00ms (10us/step)
Input Trigger Signal
3.3-24V, >5mA
rising/falling edge trigger
Output Trigger Signal
Support rising/falling edge output trigger
Trigger Delay
≤ 20us
Software Control
RS232 / TCPIP

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
4
Connectors Description
Terminal
Function
VS
Controller Power Supply +
1) LC-18-M = 24V
2) LC-18-OD-4CH-X1-48V = 48V
GND
Controller Power Supply –
COMM
Communication Port (between master and slave boards)
RS232
RS232 Communication
TCPIP
TCPIP Communication
ADDR
4 Way DIP Switch (for slave address selection)

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
5
Terminal
Function
LIGHT INPUT +
Power Supply for Lighting + (48V)
LIGHT INPUT –
Power Supply for Lighting –
CH +
Lighting Channel Output +
CH –
Lighting Channel Output –

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
6
Terminal
Function
IN +
External Input +
IN –
External Input –
OUT +
External Output +
OUT –
External Output –

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
7
Operation Mode
Strobe Mode
Strobe mode provides short interval triggering for applications that require high intensity and
high precision. An input trigger signal will turn on the lighting output based on pre-set delay
and duration parameters.
There are 4 adjustable strobe parameters available:
Strobe Delay = Delay time between the external input signal and the lighting output
Strobe Width = Duration of the lighting’s turn on time
Output Delay = Delay time between the external input signal and the external output signal
Output Width = Duration of the external output signal’s turn on time
Parameter timings are in the range of 0-9999 which is equivalent to 0-99.99ms (in step of 10us)
** Remark:
Strobe Width is fixed at 10ms maximum, adjustable in the range of 0-1000
External Trigger
Lighting Strobe
Camera Output
Strobe Delay
Strobe Width
Output Delay
Output Width

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
8
Current Multiplier
Current Multiplier setting provides more precise control of lighting intensity for lightings with
different current ratings.
Ex:
Maximum current = 1000mA/1A
Current Multiplier setting range = 1-10
1 = 10% of max output current (100mA)
2 = 20% of max output current (200mA)
3 = 30% of max output current (300mA)
4 = 40% of max output current (400mA)
5 = 50% of max output current (500mA)
6 = 60% of max output current (600mA)
7 = 70% of max output current (700mA)
8 = 80% of max output current (800mA)
9 = 90% of max output current (900mA)
10 = 100% of max output current (1000mA/1A)
For example: if the lighting’s current rating is 260mA, current multiplier can be set to 3, setting
the maximum output current to 300mA. So the lighting’s intensity can be adjusted from low to
high within the range of 0-255.
If multiplier is set too high, for example 10 (100% of max output = 1A), theadjustable intensity
range for the lighting is only about 0-67. Setting the intensity value to 68 or higher will not
have any effect towards the lighting output brightness.

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
9
LC-18 Software
The controller can be controlled using LC-18 software. Connect the controller to computer
with RS232 cable and TCPIP cable.
1. Software Connection :
a. Select COMPORT or TCPIP to connect.
b. Disconnect the software
2. Read and Save function for all slave board :
a. Read all slave board’s parameter from controller.
b. Save all slave board’s parameter into EEPROM.
3. Strobe function for all channel :
a. Strobe all channel once.
b. Repeat strobe all channel (together).
c. Repeat strobe channel by channel.
4. Reset all channel’s parameter to default value.
5. Master board firmware version.
6. Each tab display all the parameters for each slave board.
7. Display controller part number.
1
2
3
4
8
9
10
6
5
11
12
13
7
14

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
10
8. Slave board firmware version.
9. Strobe function for slave board:
a. Repeat strobe for all 4 channel.
b. Strobe once
10. Tick the checkboxes to set the address
(Address must be same as the ADDR setting on the controller).
11. Choose the channel to be strobe.
12. Save current slave board parameter to EEPROM.
13. Channel mode :
a. Strobe
14. Channel parameter :
a. Current Multiplier (1 - 10)
b. Light Intensity (0 –255)
c. Strobe Delay (0 –9999) = (0 –99.99 ms)
d. Strobe Width (0 –1000) = (0 –10.00 ms)
e. Output Delay (0 –9999) = (0 –99.99 ms)
f. Output Width (0 –9999) = (0 –99.99 ms)
For LC-18-OD-4CH-48V
1. Only strobe mode is available.
2. Maximum strobe width is 10ms.

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
11
Change IP Address
For TCPIP connection, the IP address can be changed using the Master IP Config software.
Default IP Setting:
IP Address: 192.168.0.100
Subnet Mask: 255.255.255.0
Gateway: 192.168.0.1
Step:
1) Connect using COMPort or TCPIP. Current IP will be displayed.
2) Type in the new IP address
3) Click SET button
4) Restart controller power
** Remark:
Controller power must be restarted in order for the new IP to come into effect.

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
12
Slave Board Address Setting
The address of the slave boards must be set manually before power on the controller by using
the 4-way DIP switch.
Address value is calculated in binary code
Settable address number = 0-15
SWITCH NO.
0
1
2
3
BINARY VALUE
20
21
22
23
ADDRESS 0
0
0
0
0
ADDRESS 1
1
0
0
0
ADDRESS 2
0
1
0
0
ADDRESS 3
1
1
0
0
ADDRESS 4
0
0
1
0
ADDRESS 5
1
0
1
0
ADDRESS 6
0
1
1
0
ADDRESS 7
1
1
1
0
ADDRESS 8
0
0
0
1
ADDRESS 9
1
0
0
1
ADDRESS 10
0
1
0
1
ADDRESS 11
1
1
0
1
ADDRESS 12
0
0
1
1
ADDRESS 13
1
0
1
1
ADDRESS 14
0
1
1
1
ADDRESS 15
1
1
1
1
** Remark:
Each slave board must have different address number, else the controller may malfunction

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
13
Communication Connection
All the COMM connector must be looped together for the communication between slave boards
All COMM1 and COMM2 must be looped together as shown below:

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
14
Input Signal
Input signal is used to turn on the lighting under Strobe/Trigger mode.
The lighting output is turned on after a delay time defined by Strobe Delay, while the turn on
duration is defined by Strobe Width.
Acceptable voltage for external input signal is from 3.3-24VDC.
The external trigger signal can be configured as rising edge or falling edge trigger.
Output Signal
The output signal is optional and is used to trigger external devices such as smart camera. The
output signal is only available in Strobe Mode.
The output pulse is triggered after a delay time defined by Output Delay, while the turn on
duration is defined by Output Width.

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
15
Accessories
Additional accessories that can be used with LC-18-OD-4CH-48V controllers.
24V power supply
48V power supply
Lighting cable
24V Power Supply
MODEL
SPECIFICATIONS
24V POWER SUPPLY WITH POWER CORD
24V-2.5A-UK
(24V ADAPTOR WITH POWER
CORD UK)
24V-2.5A-US
(24V ADAPTOR WITH POWER
CORD US)
24V-2.5A-EU
(24V ADAPTOR WITH POWER
CORD EU)

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
16
48V Power Supply
MODEL
SPECIFICATIONS
24V POWER SUPPLY WITH POWER CORD
48V-2.5A-UK
(24V ADAPTOR WITH POWER
CORD UK)
48V-2.5A-US
(24V ADAPTOR WITH POWER
CORD US)
248V-2.5A-EU
(24V ADAPTOR WITH POWER
CORD EU)

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
17
Cable Selection
** XX = Length
** XX = Length
MODEL
POWER
LENGTH
EXT-24V-F-XX
24V
3M
5M
MODEL
POWER
LENGTH
EXT-FL-M12F-XX
24V
3M
5M

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
18
Cable Information
i) EXT-24V-F-3M
Extension Cable of 3 Meter with SM connector
iii) EXT-FL-M12F-3M
Extension Cable of 3 Meter with M12 connector

TMS Lite LC-18-OD-4CH-48V LIGHTING CONTROLLER UNIT
19
Power Cord Information
The cable length is 1.8 Meter length of power cord.
240VAC Power Cord (UK)
220VAC Power Cord (EU)
110VAC Power Cord (US)
Table of contents
Other TMS Controllers manuals
Popular Controllers manuals by other brands

Vector
Vector TCY-T0121 manual

IAI
IAI ROBO Cylinder RCP2 Series Operation manual

DURKOPP ADLER
DURKOPP ADLER M-TYPE PREMIUM COMMANDER User training guide

Cooper Power Systems
Cooper Power Systems mcGraw Edison 9000 Replacement instructions

Intellitec
Intellitec TOUCHLITE installation instructions

MR
MR TAPCON 230 VC operating instructions