1. SAFETY PRECAUTIONS
2. GENERAL DESCRIPTION
3. FEATURES
4. NOMENCLATURES AND FUNCTIONS
Front Panel
Rear Panel
Effector Settings
5. CONNECTIONS
5.1. Input Connections
5.2. Speaker Connections
5.3. Terminal DC Input Connections
5.4. Example of External Equipment
Connections
6. RACK MOUNTING
7. BLOCK AND LEVEL DIAGRAMS
8. DIMENSIONAL DIAGRAM
9. SPECIFICATIONS
........................ 7
......... 8
....................................... 8
.................................... 9
............. 10
....................... 11
..................................... 12
............................ 2
.......................... 3
.................................................. 3
..... 4
.................................................. 4
................................................... 5
.......................................... 6
.......................................... 6
............................... 6

The ventilation should not be impeded by covering
the ventilation openings with items, such as
newspaper table-cloths, curtains, etc.
No naked flames source such as lighted candles,
should be placed on the apparatus.

3. FEATURES
y
-
y
n
-
-
s
e
e
r
y
t
y
n
it
y
n
r
When Installing The Unit When The Unit is In Use
Keep the distance for all side of units 10 cm awa
from the object that may obstruct air flow for inter
nal units temperature rise prevention.
Do not place heavy object on the unit as this ma
cause it to fall or break which may result i
personal injury and/or property damage. In addi
tion, the object itself may fall of and cause injury
and/or damage.
Make sure that the volume control is set to mini
mum position before power is switched on, Loud
noise produced at high volume when is power i
switched on can impair hearing.
Switch OFF the unit’s power before turning th
phantom power switch ON or OFF. Operating th
switch without switching OFF the main powe
could resulting a large transient noise thought the
speakers, potentially resulting in speaker failure.
Do not operate the unit for an extended period of
time with the sound distorting. Doing so ma
cause the connected speakers to heat, resulting in
a fire.
Contact your TOA dealer as to the cleaning. If dus
is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit ma
result.
If dust accumulates on the power supply plug or i
the wall AC outlet, a fire may result. Clean
periodically. In addition, insert the plug in the wall
outlet securely.
Switch off the
power, and unplug the power suppl
plug from the AC outlet for safety purposes whe
cleaning or leaving the unit unused for 10 days o
more. Doing otherwise may cause a fire or electric
shock.
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug, never pull on
the cord itself. Operating the unit with a
damaged power supply cord may cause a fire or
electric shock.
When moving the unit, be sure to remove its
power supply cord from the wall outlet. Moving
the unit with the power cord connected to the
outlet may cause damage to the power cord,
resulting in fire or electric shock. When
removing the power cord, be sure to hold its plug
to pull.
Do not block the ventilation slots in the unit’s
cover. Doing so may cause heat to build up inside
the unit and result in fire. Also periodically clean
the ventilation slots of dust.
Avoid installing the unit in humid or dusty location,
in location exposed to direct sunlight, near the
heaters, or in location generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
To avoid electric shocks, be sure to switch offthe
unit’spower when connecting speaker.
POWER
HIGH
DSP multi effect ( 4 type of Dome, Hall, Plate and Delay )
Built-in 3 Zone Selectors and Siren.
Excess current limit to prevent damage due to current overload.
Excess heat limit to protect the transistor and power transformer.
All MIC inputs are electronically-balanced input.
MIC 1 and MIC 2 equipped with phantom power for condenser microphone.
Independent input volume control and master volume control.
Independent tone control of boost and cut type for both high, middle and low frequency.
Five microphone inputs, two auxiliary inputs and one line output.
High durability, high reliability and high performance.
Avoid using Phantom power when connecting
the dynamic microphone to MIC1 and/or MIC 2,
as the microphone fails.
TOA's MX-5348-AS is Mixer Power Amplifier equipped with 5 microphone inputs, 2 auxiliary inputs and
designed for 3-zone Public address system suitable for small to middle sized mosques application, also
suited for paging announcement or BGM application in schools, offices, shops, churches and large rooms.
2. GENERAL DESCRIPTION

[Front Panel]
1. Power Switch
Press to turn ON the power.
Press again to turn off the power.
13. Siren Switch
Push the switch to activate the sound of a siren.
When the siren is active then all input will be muted,
but all input still be active on line output
terminal.
One push is one cycle sound of the siren.
Note
No sound of the siren out from the line output
terminal.
2. Power Indicator
Light green when power is switch on.
3. Signal Indicator
Light green to indicate the presence of an output
signal.
5. Volume Control for MIC
Adjust the microphone level input.
6. Volume Control for AUX
Adjust the AUX level input.
7. Low Frequency Control
Turn the control knob clockwise to enhance low
frequency and counterclockwise to weaken them.
The frequency is flat at the center position.
8. Middle Frequency Control
Turn the control knob clockwise to enhance
middle frequency and counterclockwise to weaken
them. The frequency is flat at the center position.
9. High Frequency Control
Turn the control knob clockwise to enhance high
frequency and counterclockwise to weaken them.
The frequency is flat at the center position.
10. MIC 1 -3 Effect Control
11. Effect Preset type Selection Switch
12. Effect Room size/Delay time Selection Switch
Select the reverberation / delay of effect from
“S” (Short time), ”M” (Medium time), ”L” (Long time).
When set to OFF, the effect function is disabled.
Select the type of the sound effect from
“DOME”,”HALL”,”PLATE” and “DELAY”.
Adjusts effect response.
Turn the control knob clockwise to strengthen the
response on the effect selected by the Effect
Present type selection switch (11) and
counterclockwise to weaken it.
Turning the control fully counterclockwise provides
no effect response.
14. Volume Control for Siren
Adjust the siren level.
15. Master Volume Control
Adjust overall signal level.
Note
This master volume control will not affect to the
sound of a siren level.
16. Zone Selector Knob
Push the knob to activate each correspondent Zone
Terminal.
4. Clip Indicator
Light red to indicate the output signal has
exceeded its rated. The sound start to distorted.
In such case, adjust each volume control so that
the clip indicatoris not light ON.
POWER
HIGH
5 6 16 234
12 7 13 14
15
1

21. Remote CTRL IN Terminal
To select a zone(s) by plug in the green terminal for
the desired broadcast zone(s)
17. MIC 1 -5 Input Terminal
-
60 dB*, 600 Ω, electronically balanced. Because
microphone input is a balance type, the phone plug
uses double pole type but can also use even
a single pole.
18. MIC 1 - 2 Phantom Switch
When switched ON, phantom power is supply to
the MIC input. Microphone connected to the MIC
input depends on the switch setting as follows.
ON :
-
50 dB* ( 21 V Phantom powered ). Balanced
type phantom powered condenser microphone
can be connected. ( a lavalier or gooseneck
microphone is recommended).
OFF :
-
60 dB* ( phantom power OFF ). Balanced
type dynamic microphone can be connected.
Note
Before switching on the phantom power, be sure to
turn MIC Volume Control fully counterclockwise.
Otherwise a switching noise may be produced,
possibly damaging the unit.
Be sure to select Phantom OFF when using
microphone that can not operated on phantom
power.
FACTORY PRESET : OFF
19. AUX 1 - 2 Input Terminal
-
10 dB*, 10 kΩ, Unbalanced. Monaural RCA pin
jack. Accept external equipment output signal.
20. Line Out
0 dB*, 600 Ω, Unbalanced. Output all input signals
before the Master Volume Control. Connect to a
cassette deck, etc when recording the broadcast
content or other input amplifier.
Note
No sound of a siren out from the Line Out Terminal.
28. Functional Ground Terminal
Noise may be generated when external equipment
is connected to the unit. In this case, connect this
terminal to the functional ground terminal of the
external equipment, and the noise may be reduced.
Note
This ground is not for protective ground.
25. Terminal Cover
To avoid shock by high voltage from output
terminal. Please put back terminal cover after
connecting
22. Zone Selector Output Terminal
Connect output terminal to speaker. When
connecting to the speaker please use only High
Impedance speaker only.
23. Output Terminal
Connect output terminal to speaker. When
connecting to the speaker please use only one
output terminal, either High or Low Impedance.
26. Fuse
Replace only the same type of fuse. ( F10A 250V )
27. AC Power Cord
Connect to an AC power source.
24. DC Input Terminal
Connect input terminal to a DC power source or
Battery. Connect negative ( - ) terminal of DC source
or battery to all ( - ) DC Input Terminal and positive
( + ) terminal of DC source or battery to all ( + ) DC
Input Terminal.
* 0 dB = 1V
FUSE
26 22 18
17
28
17
19
20
25
23
24
(
For detail please see page 8 )

To adjust, rotate the Effector Control Knob. The effect becomes more pronounce as the
knob rotated clockwise and weakens as the knob rotated counterclockwise.
3
12
es
5. CONNECTIONS
5.1. Input Connections
Using effector type and settings.
This unit built-in effector function offers a range of settings. The effector is enabled whenever the Effect
Room Size/Delay Time Selection switch is set to any other position than OFF . When enabled, the effector
is applied only to input MIC1 -MIC3.
[Effector Settings]
Effect Name
HALL
DOME
DELAY
PLATE
Effect Description
Creates an effect of wooden walls with carpeted floors.
Creates an effect of stone with semi-domed ceiling.
Creates an effect of sound being repeatedly reflected following delay.
Creates an effect of metal reverberation as by a metal plate hung from the ceiling,
accompanied by an extended high frequency band.
Step 1. Select the type of effect to be used with the Effect Preset Type Selection switch.
delay time condition using the Effect Room Size / Delay Time Selection switch :
M
L
OFF
S
DOME, HALL or PLATE settings
Medium reverberation time.
Long reverberation time.
Effector disabled.
Short reverberation time.
DELAY settings
Medium delay time.
Long delay time.
Effector disabled.
Short delay time.
Note : The effector is enabled after 3 seconds [ Room size/Delay time ] is selected.
Step 2. Enable or Disable ( ON/OFF ) the effector and select the reverberation time and
Step 3. Adjust the effector’s response strength.

5.2. Speaker Connections
Impedances indicate at the terminal represent the total impedance (load) of the speaker system.
- Total impedance in “4 ΩLine” must same or over than 4 Ω.
- Total impedance in “100 V Line” must same or over than 21 Ω.
Terminal 4
Ω
and 100 V cannot be use together.
CAUTION !
Using Terminal Output.
Using Zone Selector Terminal
100 V Line Speaker
Using Remote CTRL IN Terminal
Speaker ZONE 1
Speaker ZONE 2
Speaker ZONE 3
Remote ZONE 1
Remote ZONE 2
Remote ZONE 3
Switch Remote ZONE 1 to activate the Speaker ZONE 1
Switch Remote ZONE 2 to activate the Speaker ZONE 2
Switch Remote ZONE 3 to activate the Speaker ZONE 3
Please put the terminal cover in place after installing the speaker cable. Due to the voltage
on the speaker terminal which may cause electric shock, you must not touch the terminal.
Speakers
100 V Line Speaker
Speaker

5.3. Terminal DC Input Connections
F 10A L
FUSE
Dynamic Microphone (Phantom switch “OFF”) or
Condenser Microphone (Phantom switch ”ON”)
Remote Control Switch
5.4. Example of External Equipment Connections
Direct Output
Box Speaker
Zone 3
Box Speaker
Zone 2
Horn Speaker
Zone 1
Horn Speaker
TOTAL IMPEDANCE
LINE SPEAKER 100 V : 21 Ω
All Terminal DC Input Must be connected to the DC Supply/Battery Terminal.
Dynamic Microphone
Dynamic Microphone
Dynamic Microphone
Recording Device
Power Amplifier
Media Player
OR
Note :
Connections that are not in accordance with the picture above, can cause damage to the components.
Battery 12V Battery 12V Battery 24V
External Audio

6. RACK MOUNTING
To mount the unit in an equipment rack, use the optional MB-36 Rack mounting bracket.
Step 1. Remove the 4 plastic feet attached to the bottom surface of the unit.
Step 2. Attach the MB-36 to the unit using the supplied 4 screws.
Step 3. Mount the unit on the equipment rack.
Note
Be sure to use the supplied screws.
M4 x 16 Machine screw ( supplied with the MB-36 )
3
2
MB-36
Plastic foot
Rack-mount installation precautions
Recommend to use the guide rail to support
the rack mounting of the unit.
Due to the heavy unit, better to install in rack
system at lower rack position.
Rack-mounting screws are not supplied with
the unit, prepare them that are appropriate for
the equipment rack.
Perforated panel
MX-5348-AS
unit
POWER
HIGH
To improve ventilation, ensure that a perforated
panel (panel with ventilation openings) of 1-unit
size or greater is mounted over and under the
unit, as well as on the top and at the bottom of
the rack.
Perforated panel

7. BLOCK AND LEVEL DIAGRAMS

8. DIMENSIONAL DIAGRAM
420 [16.54"]
Measurement unit : mm (inch)
142.6 [5.61"]
132[5.19"]
361 [14.21"]
320 [12.59"]
[ 82.68"- 90.55" ]
2100 - 2300
22.8 [0.89"]
POWER
HIGH

9. SPECIFICATIONS
Power Consumption
Power Source
Current Consumption
220 - 230 V AC, 50/60 Hz
DC : 24 V DC (Operating range : 19.5 - 27 V)
M4 screw type, distance between barrier : 12 mm
AC at rated output : 1190 W
AC at no signal : 20 W
EN 62368-1 : 455 W
DC at rated output : 31 A
DC at no signal : 0.5 A
EN 62368-1 : 11 A
MIC 1 - 2
MIC 3 - 5
AUX 1 - 2
Speaker Selector
Speaker Out
Output
Input
1 mV ((-50 dB* (24 V Phantom powered)/ -60 dB* (Phantom power OFF))
1 mV (
-
60 dB*), 600
Ω
,
Balance
d, Phone Jack
300 mV (
-
10 dB*), 10 k
Ω
, Unbalanced, RCA pin jack
3 Zones, High impedance (100 V line)
Speaker Ouput in screw type terminal
600
Ω, Balanced,
Phone Jack
Line Out
Frequency Response
Effect Control
Indicator
Signal Buzzer
Operating Temperature
Ventilation
Dimensions
Finish
Weight
Accessory
0 dB*, 600
Ω
, Unbalanced, RCA pin jack
80 Hz - 15000 Hz, 3 dB, 1 kHz
Low :
Mid :
High :
Tone Control
MIC 1 - 3 effect :
Effect Preset type selection switch (DOME/HALL/PALTE/DELAY)
Effect Room size / Delay Time selection switch (L/M/S/OFF)
POWER, SIGNAL, CLIP
Siren
One push is one cycle of siren sound
0 °C to +40 °C (32 °F to 104 °F)
Fan Cooling
Removable terminal plug (2 pins) ... 3
19.0 kg
Panel : Aluminium, Black, Painting
Case : Steel Plate, Black
420 (w) x 142.6 (h) x 361 (d) mm (16.54” x 5.61” x 14.21”)
10 dB at 100 Hz
10 dB at 2.5 kHz
10 dB at 12 kHz
DC +21 V (MIC 1, MIC 2)
Effect Control (0% to 100%) of Line out
Individual selector
Direct Line
High impedance 21
Ω
(100 V)
Low impedance 4
Ω
Table of contents
Other Toa Amplifier manuals

Toa
Toa A-2060D SERIES User manual

Toa
Toa BG-1015 User manual

Toa
Toa A-230 HV User manual

Toa
Toa DA-250D User manual

Toa
Toa BG-2035 Operating and installation instructions

Toa
Toa 9000 Series User manual

Toa
Toa DA-1000F User manual

Toa
Toa BA-260 User manual

Toa
Toa P-3248D-AS 1 User manual

Toa
Toa WA-1822 User manual