Reset
Counting
value SET
Display
2 KKTCN-B01E-20200630
IV. Operation instruction
1. The input wire should not be too long, better be shielded. Don’t use the instrument in the ambient humidity>90%RH or strong acid.
2. In case the vibration of input signal is too strong, please connect a 10UF~33UF capacitor filter in parallel to the input terminal of the instrument.
3. In the occasions of withstand voltage test on electrical circuit and Uncharged metal, please remove or short circuited the counter from the
circuit. (Otherwise, the CMOS circuit could be damaged).
4. To ensure the normal service life of dial switch and other components, please prevent dust from entering the instrument.
F N R C OUT
TIM OUT RST
9 9 9 9 9 9
Display
Measuring
Value
Display Delay
Time
Delay Time
Setting
Thrumb Switch
Reset
Output Mode
Selecting
V. Operations
1. The display and keys on the panel as the illustrate
2. TIM key is to modify the delay time. When the delay time is 0,
press TIM key the first time, delay time will be increased to 0.2s;
press it the second time, delay time will be increased to 0.4s (0.2
and 0.4 second is still displayed as 0); press it the third time,
delay time will be increased to 1s, display as 1; since then, each
press will increase 1 second till to 15 senconds.
3. Press OUT key for 3 seconds to enter the output mode to
selecting estate. Press OUT key to select F, N, R,C, the relative
lamp of F, N, R, C will be on. Stop pressing OUT key for 3s, it will
confirm and exit automatically.
F, N mode no delay time setting
Delay time display Delay time displayActual delay time (S)Actual delay time (S)
0
1 1 9
2
3
4
5
6
7
2
3
4
5
6
7
8
9
10
11
12
13
14
15
8
Blank screen
0;0.2 or 0.4
VI. Counter output mode diagram
4 kinds of relay output modes for option: F, N, R, C.
Output
mode
setting
Action
after
Counting
Output and counting value
will remain till reset. Counting value goes on,
output will remain till reset.
Whencountingvaluereaches
setting value, the display value
and output will remain till the
setting delay time, then reset
to next counting automatically.
The counter will reset the
counting value when it
reaches the setting value, but
the output will remain till the
setting delay time, then reset
to next counting automatically.
0
OUT
NF
Reset
999999
Counting
value SET
Display
OUT
0
R
0
OUT
C
Reset
Counting
value SET
Display
Reset
Counting
value SET
Display
OUT
0
VII. Wire connection and connecting method with proximity sensor
Note: Please subject to the connection drawing on the counter if any changes.
RST
RST
3 5
INPUT GND GND GND24V
1 2 3 4 5 6 7
8 9 10 11 12
AC/DC 100~240V
POWER
13 14 15 16 17 18 19
OUT
NO COM NC
Wire connection
POWER
OUT
GND
Proximity sensor Counter
4
1
3
4
1
3
POWER
Proximity sensor Counter
1K-4.7K
OUT
GND
~