KKCA101-A/2-1
CA 0
CA4-RB60
CA7-RB60
CA8-RB60
48W×48H×102L
72W×72H×100L
96W×48H×100L
220VAC
110/220VAC
110/220VAC
4:(48×48)
7:(72×72)
8:(48×96)
48
72
96
AH(Min)
G
BCDE FJ
48
72
48
108
109
109
6
9.5
9
102
99.5
100
45.5
67.5
90
25
25
25
45.5
67.5
45
45
67
44.5
K(Min)
25
25
25
A
B
C
E
D
F
G
K
J+0.5
-0
+0.5
-0 H
220VAC±10% 50H/60Hz
≤4W
250VAC/3A
DC18V±5V(≤25mA)
≥20MΩ
1.5KV/1M
≤1/30/300/1000Hz
0.01600.00s
0.019999.99
2ǃ10ǃ100ǃ500Hz (selectable)
0.01999999
CA Series Counter Meter
6
6
6
Alarm Output
One relay alarm
One relay alarm
One relay alarm
Power supply
External Reset Frequency
Side face size Mounting size
Model
Remark Unit: (mm) Tolerance ±0.5%(special annotation not be included)
CA series Digital Counter user manual
CA series Digital Counter user manual
Features:
1. Dual line 6 digit LED display
Dual line 6 digit LED displayˈ
2. Optional dimension
48×48, 48x96, 72×72
3. Single counting, single relay output
Single counting, single relay outputˈ
4. Manual reset, automatic reset, key lock function
Manual reset, automatic reset, key lock functionē
power fail memory function
power fail memory functionˈ
5. Settable counting coefficient, NPN or PNP input selectable
Settable counting coefficient, NPN or PNP input selectableˈ
6. Widely applied to the industries relevant to timber machining,
Widely applied to the industries relevant to timber machining,
food machinery, packing machinery, steel machining, etc.
food machinery, packing machinery, steel machining, etc.
1.
Model Indication
0: Design code
6: 6 digit
B: One alarm
R: Relay output
4:48W×48H(mm)
7:72W×72H(mm)
8:96W×48H(mm)
CA series counter
Model Dimension(mm) Digit
2.
Technical Parameter
Power Supply
Total Power Consumption
Relay Capacity
Output Power
Insulation Resistance
Insulation Strength
Counting Input Speed
Counting Range
Delay Time
Coefficient Setting Range
External Signal
(selectable)
3.
Dimension & Connection
Front face size