MODEL
ITEM
Capacity 220V 240V 220V 240V 220V 240V 220V 240V 220V 240V 220V 240V
kW 6.306.306.80 6.90 6.80 6.85 5.00 5.05 5.45 5.55 5.30 5.35
Phase 1∅
Power source V220 -240
Hz
50
Power consumption W2430 2510 2400 2480 2560 2690 1850 1900 167817481860 1960
Power factor %9885 99 88 99 92 989794929796
220V 240V 220V 240V 220V 240V 220V 240V 220V 240V 220V 240V
Running current A0.3/ 0.3/
0.3/0.3/11.75 0.3/12.20 0.3/0.3/0.3/0.3/0.3/8.40.3/8.2
Indoor/Outdoor 11.0 11.23
8.37.9 7.87.6
Starting current A54
36
Moisture removal lit/h 2.5 2.7 2.0 2.0
Noise Indoor (H/M/L) dB
45/43/41/39/37
44/42/39/37/35
Outdoor (220-240V) dB 56-57 57-58 56-57 52-5353-5451-52
Refrigerant Name of refrigerant R410A
Rated amount kg 1.70
1.15
1.26
Refrigerant control Capillary tube
Gas side size mm ∅12.7
Connection type Flare connection
Liquid side size mm ∅6.35
Interconnection Connection type Flare connection
pipe Maximum length m15*1
(One way) 25*220*2
Maximum height m 8
difference
INDOOR UNIT RAS-24GKHP-ES2RAS-24GKP-ES2RAS-18GKHP-ES2RAS-18GKP-ES2
Height mm 298
Dimensions Width mm 998
Depth mm 220
Net weight kg 13
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m3/h 900900900900 900 900
Air volume Medium fan m3/h 750 800 750 667 708667
Low fan m3/h 625 667 625 543584 543
Fan motor output W30
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-24GAH-ES2RAS-24GA-ES2RAS-18GAH-ES2RAS-18GA-ES2
Height mm 715
Dimensions Width mm 780 780 780
Depth mm 290
290
Net weight kg 56 52 44 39
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m3/h 2400 2550 2400 2550 2400 2550 2350 2450 2350 2450 2120 2200
Fan motor output W42 42
Compressor Model PA290X3CS-4MU1 PA225X2CS-4KU1
Output W 2160 1500
Safety device IOL, Td Sensor IOL IOL, Td Sensor IOL
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43 -10 ~ 24 21 ~ 43 15 ~ 43 -10 ~ 24 21 ~ 43
1. SPECIFICATIONS
RAS-24GKHP-ES2RAS-24GKP-ES2RAS-18GKHP-ES2RAS-18GKP-ES2
RAS-24GAH-ES2RAS-24GA-ES2RAS-18GAH-ES2RAS-18GA-ES2
Cooling Heating Cooling Cooling Heating Cooling
10
33
10.7 0.3/
11.45
54
1.90
550
290
Note *1 Chargeless pipe
*2 Maximum pipe
FILE NO. SVM-06020
550
-3-