manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Toshiba
  6. •
  7. Air Conditioner
  8. •
  9. Toshiba TCB-GB1602UE User manual

Toshiba TCB-GB1602UE User manual

–1–
EN
Air Conditioner
INSTALLATION MANUAL
<4-way air discharge cassette type>
Fresh-Air Inlet Box
MODEL: TCB-GB1602UE
Thank you for purchasing the “Fresh-Air Inlet Box” of TOSHIBA Air Conditioner. Before starting the installation work,
please read this manual carefully and install the product properly.
PRECAUTIONS FOR SAFETY
• Before installing the product, pleaseread the“
PRECAUTIONS FOR SAFETY
” carefully to performtheproper installation.
• Be sure to keep the instructions described in the precautions for safety, since the descriptions include the important
information for safety. The indication and the meaning of the symbols are as below.
*1:Bodily injury indicates injury, burns, electric shock, and other injuries which do not require hospitalization or long-term
treatment as an outpatient.
*2:Physical damage indicates the damage relating to the property, material.
CAUTION ON INSTALLATION
WARNING
Use TOSHIBA products for the parts sold separately.
Use the products specified by TOSHIBA for the parts sold separately, such as the fresh-air chamber, ceiling panel, etc.
The use of the products other than specified may cause the water leakage, electric shock, fire, etc.
CAUTION
Turn off the earth leakage breaker when installing the fresh-air inlet box.
Be sure to attach the fresh-air inlet box to the fresh-air chamber.
Insufficient installation may cause the water leakage, electric shock, etc.
1. Applicable models
2. Components
(The following parts are attached.)
WARNING This sign denotes that serious injury may result from improper use.
CAUTION This sign denotes that the bodily injury*1or damage*2to property may result from improper use.
Indoor unit RAV-SM∗∗4UT-E
Fresh-Air Chamber TCB-GFC1602UE
No. Name Shape Q’ty No. Name Shape Q’ty No. Name Shape Q’ty Remark
➀Outside air
introduction
port 1➃Mounting
screws
(4 x 10) 16 ➆Wind shield 1 –
➁
Outside air
introduction
port fixing
metal part 1➄Heat
insulating
material A 2➇Installation
manual 1This
manual
➂Duct flange
(Ø100) 1➅Heat
insulating
material B 2
1-EN
+00CH78994901_10L_TCB-GB1602UE.book Page 1 Wednesday, April 30, 2008 4:26 PM
–2–
EN
3. Installing the fresh-air inlet box
CAUTION
The fresh-air inlet box should be installed after installing the indoor unit. Further attention is required since the fresh-air
inlet box is attached to the fresh-air chamber. Applying the shock to the side of the fresh-air chamber may damage the
product.
(1) Attach the fresh-air chamber to the indoor unit following to
the instructions described on the fresh-air chamber
installation manual.
(2) Remove the shield of the fresh-air chamber. (Fig. 1)
(3) Install the indoor unit (with fresh-air chamber) to the ceiling.
(4) Attach the duct flange ➂and the outside air introduction
port fixing metal ➁to theoutside air introductionport➀and
fix with 8 mounting screws ➃. (Fig. 2)
(5) Fix the fresh-air inlet box set in step (4) to the fresh-air
chamber with 6 mounting screws ➃(Side: 4 screws,
bottom: 2 screws).
(6) Attach the heat insulation material A ➄and B ➅to the
mounting screws portions. (Fig. 1)
(7) Install the ceiling panel sold separately following to the
instructions described on the fresh-air chamber installation
manual and lay the wiring for the louver motor wiring
connector.
(8) After installing the panel, fix the wind shield ➆to the
position wherethe suction grille is removed as shown in the
Fig.3 with 2 mounting screws ➃. If the wind shield is not
fixed, it is impossible to control the room temperature. This
may cause improper operation.
CAUTION
Be sure to provide the opening for inspection on the fresh-
air inlet box side. (The outside air introduction port is
removed when servicing.)
4. Confirming the installation
After the installation completes, perform the trial run to confirm that no abnormality is found.
For your future reference, please keep the installation manual on your side.
➄Heat insulating
material A
Shield plate (Remove)
(Fig. 1) ➅Heat insulating material B
➂Duct flange
➃Mounting
screws
➀Outside air
introduction port
➁Outside air
introduction port
fixing metal part
➃Mounting
screws
➆Wind shield
➃Mounting screws
After installing the panel, fix the wind shield ➆
with the mounting screws ➃.
(Fig. 2)
(Fig. 3)
Inspection opening (450)
2-EN
+00CH78994901_10L_TCB-GB1602UE.book Page 2 Wednesday, April 30, 2008 4:26 PM
–3–
EN
CAUTION
• The outside air should be processed by the heat exchanger, etc.
(The outside air temperature range after processing: 12°C~30°C)
• Be sure to install the return duct.
• The duct fan for the outside air introduction shall require the interlock wiring.
• The sound insulation chamber shall be required to prevent from occurring the operating sound.
• The connection duct is not supplied with the product. Please procure Ø100 flexible duct on the market.
1 Mounting the connection duct
• Setthe flexibleductto theexternal sideof theflangecircle
and fix it by using a band at 25 to 30 mm position from the
edge of the flexible duct.
2 Sealing the connection port
• Wrap the tightening band with the heat insulating
materials of 20 mm thickness or more.
• Apply the adhesive tape around the heat insulating
materials of the connection port to prevent the heat
insulating materials from peeling off.
CAUTION
• Seal the connection port without any clearance to
prevent from dew condensation.
• Keep the thermal insulation around the duct and the
connection port.
(If the thermal insulation is not applied, the dew
condensation may occur due to the temperature
difference between the outside air and the air staying in
the ceiling.)
3 Installing the duct
• Perform the indentation ventilation on the fresh-air inlet
box using the duct fan shown in the right figure.
CAUTION
• Confirm the processed outside air should be ranged
from 12 to 30°C.
• Confirm the sound insulation chamber is installed.
Duct connection and installation
Indoor unit
Flexible duct
Fresh-air inlet
box
Tightening band
Fresh-air
chamber
Indoor unit
Fresh-air
chamber
Tightening
band
Adhesive tape
Flexible duct
Heat insulating materials
(thickness: 20 mm or more)
Fresh-air inlet box
Indoor unit
Fresh-air
chamber
Sound
insulation
chamber
Duct fan
Outside air filter
Processed
outside air
Fresh-air inlet box
3-EN
+00CH78994901_10L_TCB-GB1602UE.book Page 3 Wednesday, April 30, 2008 4:26 PM
–4–
EN
4 Duct fan wiring
• The interlock wiring should be applied between the duct fan and the indoor unit ventilator.
Insert the connector to CN60 on the main P.C. board of the indoor unit and connect the duct fan driving relay (DC12V)
between pins ➀and ➅.
The thick line ( ) shows the connection circuit.
• After installing the duct, perform the trial run to confirm whether the duct fan and the ventilation of the indoor unit work
starting or stopping at the same timing. (For the trial run, following to the instructions described on the indoor unit
installation manual.)
Closed end connector
Closed end connector
Main control
P.C. board
MCC-1570
Duct fan drive relay
220V - 240V AC
Duct fan
(White)
RELAY
Use TCB-KBCN60OPE
(Sold separately)
4-EN
+00CH78994901_10L_TCB-GB1602UE.book Page 4 Wednesday, April 30, 2008 4:26 PM

Other Toshiba Air Conditioner manuals

Toshiba RAS-25S4KVDG-ND User manual

Toshiba

Toshiba RAS-25S4KVDG-ND User manual

Toshiba Carrier RBC-AX33C-UL User manual

Toshiba

Toshiba Carrier RBC-AX33C-UL User manual

Toshiba RBC-AXU31UM-E User manual

Toshiba

Toshiba RBC-AXU31UM-E User manual

Toshiba RAS-25 Series User manual

Toshiba

Toshiba RAS-25 Series User manual

Toshiba RAS-10BKCV-T User manual

Toshiba

Toshiba RAS-10BKCV-T User manual

Toshiba R32 User manual

Toshiba

Toshiba R32 User manual

Toshiba RAV-M242A-E User manual

Toshiba

Toshiba RAV-M242A-E User manual

Toshiba RAS-1 8SKII-E User manual

Toshiba

Toshiba RAS-1 8SKII-E User manual

Toshiba Carrier TCB-IFDMR01UP-UL User manual

Toshiba

Toshiba Carrier TCB-IFDMR01UP-UL User manual

Toshiba RBC-AX33UYP-E User manual

Toshiba

Toshiba RBC-AX33UYP-E User manual

Toshiba RAV-SM456BTP-E User manual

Toshiba

Toshiba RAV-SM456BTP-E User manual

Toshiba 28U2KCV2G-T User manual

Toshiba

Toshiba 28U2KCV2G-T User manual

Toshiba RAS-10YAV-E User manual

Toshiba

Toshiba RAS-10YAV-E User manual

Toshiba RAS-5M51U2ACVG-SG User manual

Toshiba

Toshiba RAS-5M51U2ACVG-SG User manual

Toshiba RAS-M07N4KVRG-E User manual

Toshiba

Toshiba RAS-M07N4KVRG-E User manual

Toshiba MMU-AP0092H User manual

Toshiba

Toshiba MMU-AP0092H User manual

Toshiba MMC-AP0157HP-E (TR) User manual

Toshiba

Toshiba MMC-AP0157HP-E (TR) User manual

Toshiba MMC-UP0151HP-E User manual

Toshiba

Toshiba MMC-UP0151HP-E User manual

Toshiba RAC-PD0811CRU User manual

Toshiba

Toshiba RAC-PD0811CRU User manual

Toshiba RAV-SM563UT-E User manual

Toshiba

Toshiba RAV-SM563UT-E User manual

Toshiba MMU-UP0031YHP-E User manual

Toshiba

Toshiba MMU-UP0031YHP-E User manual

Toshiba RAV-SM563UT-E User manual

Toshiba

Toshiba RAV-SM563UT-E User manual

Toshiba RAS-M10GDCV-E User manual

Toshiba

Toshiba RAS-M10GDCV-E User manual

Toshiba MMK-AP0073H User manual

Toshiba

Toshiba MMK-AP0073H User manual

Popular Air Conditioner manuals by other brands

Fujitsu ASYG 09 LLCA installation manual

Fujitsu

Fujitsu ASYG 09 LLCA installation manual

York HVHC 07-12DS Installation & owner's manual

York

York HVHC 07-12DS Installation & owner's manual

Carrier Fan Coil 42B Installation, operation and maintenance manual

Carrier

Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity IDUFCI60KC-3 installation manual

intensity

intensity IDUFCI60KC-3 installation manual

Frigidaire FAC064K7A2 Factory parts catalog

Frigidaire

Frigidaire FAC064K7A2 Factory parts catalog

Sanyo KS2432 instruction manual

Sanyo

Sanyo KS2432 instruction manual

LG MultiV Series installation manual

LG

LG MultiV Series installation manual

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

CLIMAVENETA

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea EWK06CW5 user manual

Midea

Midea EWK06CW5 user manual

Pioneer FAB Series installation manual

Pioneer

Pioneer FAB Series installation manual

SPT WA-1511S user manual

SPT

SPT WA-1511S user manual

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Mitsubishi Electric

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic CS-S18HKQ Service manual

Panasonic

Panasonic CS-S18HKQ Service manual

Panasonic CS-E15NKE3 operating instructions

Panasonic

Panasonic CS-E15NKE3 operating instructions

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Friedrich ZoneAire Compact P08SA owner's manual

Friedrich

Friedrich ZoneAire Compact P08SA owner's manual

Daikin R32 Split Series installation manual

Daikin

Daikin R32 Split Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.