SUMMARY
The idea behind the unit is a localized dehumidification. The unit
will greatly enhance your personal comfort whether at a work of-
fice, bathroom or even in your favorite closet.
It dries the air so that you can stay comfortable even when it’s hu-
mid or rainy outside. Also your furnishings, fabrics and clothes are
kept in good condition, and it is easy to dry your laundry and dry it
quickly.
This unit creates dry air zone anywhere you need it. It means that it
does not waste energy drying the surroundings.
It’s easy to operate. Once you set your desired level of relative hu-
midity from 60% to 40%, the built-in humidistat allows the room
humidity to be controlled automatically.
By connecting the commercially available hose to the unit, you can
use it as continuous drainage mode. This is especially convenient
for using in the outside such as garage.
OPERATIONAL FEATURES
1. DEHUMIDIFYING OPERATION:
This unit takes in the humidity and dry air is directed out from
the air outlet by the compressor.
2. AUTOMATIC OPERATION:
Once the desired function has been set, it is memorized as
long as it remains connected to the wall outlet. In the event of
a power failure, the desired function must be re-entered when
power is restored.
3. HUMIDITY CONTROL:
The compressor will automatically shift to ON or OFF to main-
tain the desired humidity.
4. AUTOMATIC SHUT-OFF MECHANISM WHEN THE DRAIN
TANK IS FULL:
When the drain tank is full, the unit will be automatically shut
off. The “FULL” lamp will light. It will resume operation after
the condensed water is removed from the tank.
5. AIR FILTER:
A pre-filter protects the unit from dust.
1. DESCRIPTION
Fig. A FRONT
A1 Air outlet
A2 Front panel
A3 Operation panel
A4 Carrying handle
A5 Power supply cord
A6 Power plug
Fig. B REAR
B1 Air intake
B2 Drain water outlet for continuous drain operation
B3 Water tank
B4 Water gauge
Fig. C OPERATION PANEL
C1 Power button
C2 Off timer button
C3 Timer indicator lamp (2, 4, 6 hours)
C4 Humidity setting button
C5 Cont. lamp (Continue lamp)
C6 40% humidity setting lamp
C7 50% humidity setting lamp
C8 60% humidity setting lamp
C9 Defrost lamp
C10 Full lamp
(When the tank filled up with water, the lamp will light)
Fig. E CONTINUOUS DRAINAGE
E1 Drainage hose
2. SAFETY TIPS
IMPORTANT
• Read instructions carefully before operation.
•
The unit should be operated when the room temperature is be-
tween 5°C to 35°C. If the room temperature is below 5°C, ice
may form on the coils. If the room temperature is above 35°C,
the compressor will automatically shut off to protect itself.
• ALWAYS, wait 3 min. to restart after turning unit off.
WARNING
• NEVER expose infants, handicapped persons, or se-
nior persons directly to the airflow. Adjust the airflow
direction.
• Keep children away from unit. Children are particu-
larly liable to this danger. The inside fan is running at
high speed. Covering them may deteriorate dehumid-
ifier performance or cause it to become inoperative.
• NEVER insert objects of any kind into the air intake or
air outlet.
• DO NOT unplug or plug in if your hands are wet. An
electrical shock may occur.
• DO NOT operate in a wet location.
• ALWAYS plug into 220-240V, 50Hz, single phase elec-
trical outlet.
• Be sure the power plug fits the receptacle securely.
• DO NOT run power cord under carpets, rugs, or floor
mats of any kind.
• DO NOT attempt to shorten or alter power cord in any
way.
• DO NOT apply any excessive force or pressure to the
power supply cord.
• Make sure that the plug is free of dust.
• DO NOT use an extension cord.
• DO NOT use multiple power points.
• DO NOT turn on and off by inserting or removing the
power plug, which may cause electric shock or fire.
• If there is a fear of lightning, stop the unit and dis-
connect the power supply cord.
• DO NOT touch the evaporator, condenser and pipes.
• DO NOT operate with filter removed.
• If the power cord on this unit is damaged, it must be
replaced by the manufacture, its service agent or
qualified persons in order to avoid a hazard.
• This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision
or instruction concerning use of the appliance in a
safe way and understand the hazards involved.
• Children shall not play with the appliance.
• Cleaning and user maintenance shall not be made by
children without supervision.
• The appliance shall not be installed in the laundry.
• The appliance shall be installed in accordance with
national wiring regulations.

ENGLISH
2
CAUTION
• Ensure there is 30 cm of clear space on all sides of the unit.
(Fig. F)
• Remove drain water before moving unit.
• To minimize corrosion, DO NOT use in damp, salty air area.
• DO NOT operate in direct sunlight.
• DO NOT use for such particular purpose as preservation of
foodstuff, animals, plants, precision appliances, arts and med-
icine.
• DO NOT place an animal, plants or combustion equipment in
a place which is subjected to the direct air flow of the unit.
• DO NOT ride or place the objects on the unit.
• DO NOT turn the product on its side or upside down.
• Waste electrical products should not be dispose
with household waste.
• Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.
3. OPERATION
OPERATING STEPS:
1. CONNECT POWER PLUG (A6) TO POWER SOCKET.
Make sure the water tank (B3) is placed in proper position, and
then connect to the power socket.
If the tank is not in proper position, the FULL lamp (C10) will
light after plug on. If FULL lamp lights at the first time, please
pull out the tank once and push it back to the proper position.
2. PRESS POWER BUTTON (C1) TO ON.
3. PRESS THE HUMIDITY SETTING BUTTON (C4)
Press the humidity setting button (C4) to select your desired
humidity mode.
By pressing the humidity setting button, the indication lamp
will shift to:
“Continuous” (C5) ➞“40%” (C6) ➞“50%” (C7) ➞“60%” (C8)
➞“Continuous” (C5),
and your desired humidity mode can then be selected.
When the desired humidity level is set at “Continuous-mode”
(C5), the unit will keep dehumidifying.
When the humidity level is set at “40%”, “50%”, or “60%”, the
unit will stop at this set humidity.
PLEASE NOTE: When the unit has measured the set hu-
midity level, the compressor will stop, but
the fan will keep running to circulate the
surrounding air, and thereby continue
measuring the humidity level in the sur-
rounding room.
4. TIMER OPERATION
Press off timer button (C2) to set the working hour of units 2h
➞4h ➞6h ➞No timer.
5. PRESS POWER BUTTON (C1) TO OFF.
4. EMPTY THE WATER TANK (Fig.D)
When the water tank is full, the full lamp (C10) will light and
the compressor will stop automatically. This will also stop
the dehumidification process.
• Empty the water tank and replace it in the correct posi-
tion. (D2, D3) The dehumidifier will continue dehumidify-
ing when the compressor automatically starts after three
minutes.
5. CONTINUOUS DRAINAGE WATER (Fig. E)
If desired, it possible to connect the drainage hose (E1) to the
device for permanent water drainage. Connect the drainage
hose to the drain spout and ensure that the end of the hose is
lower than the drain opening, otherwise the water will not
drain and flooding may occur. (E2, E3, E4).
6. DEFROSTING
When the machine is in the environment of low tempera-
ture durying operation, the surface of the evaporator may
frost. In order to ensure the normal operation of the ma-
chine, machine is provided with an automatic defrosting
function.
7. MAINTENANCE & CLEANING
For its casing is made of plastic, do not place it in direct
sunlight.
Remove the water tank with care.
If not using the unit for a long time. Please switch off and
unplug the unit, empty the water reservoir, and pack it after
2 days, then, keep it in dry and ventilated place.
Only use a soft clean cloth for all cleaning purpose. Do not
use gasoline, paint thinner or other chemicals to clean the
unit.
Cleaning mesh filter: To remove the filter in arrow direction
(G1). Use a vacuum cleaner or water to clean (G2), then
put it in ventilated place until it's dry.
WARNING
• DO NOT touch the evaporator. It may cause injury or damage.
CAUTION
• DO NOT use over 40°C hot water. The plastic part may be de-
formed.
• Disconnect the power supply before cleaning and mainte-
nance.
CLEANING SURFACE
Clean the outside of the product with a soft damp cloth.
8. TRANSPORTATION
Preferably keep the unit in the vertical position during transporta-
tion. If it is necessary to place the unit in a horizontal position more
than 1/2 hour, ALLOW IT TO REMAIN UPRIGHT FOR 24 HOURS
BEFORE OPERATION. Failure to do so may result in damage to the
compressor. Before transporting / moving the unit make sure the
drain tank is empty.

9. TROUBLE SHOOTING
Check the following before contacting technical support:
Problem Cause Solution
The unit does
not work. The power is not con-
nected. Insert the plug into the
wall outlet.
The device
does not de-
humidify.
The water tank is full. Remove the water from
the container.
The water tank has not
been replaced correctly.
Place the water tank in
the correct position.
The air filter is clogged. Clean the air filter.
The temperature or rela-
tive humidity in the room
where the device operat-
ing is too low.
It is normal that the de-
vice does not dehumidi-
fy in these conditions.
The dehu-
midifier
works, but
reduces the
relative hu-
midity insuffi-
ciently.
The room is too large. We recommend using a
dehumidifier with a
greater capacity.
There are too many
sources of humidity. We recommend using a
dehumidifier with a
greater capacity.
There is too much venti-
lation. Reduce ventilation (e.g.
close windows and shut
doors.)
BEFORE CALLING FOR SERVICE
The following are not defects.
A hissing noise or hol-
low sound: This sound is generated from the
refrigerant flowing within pipes.
A squeaking noise:
This noise is generated from the
unit when it is expands or contracts
with temperature changes.
Odor:
Such odor as tobacco, cosmetics,
or foods may accumulate in the
unit.
The unit does not start
nor change operation
mode immediately:
To prevent overloading the com-
pressor motor, the unit will be
stopped for more than 3 minutes.
10. SPECIFICATIONS
MODEL TD-C210
DEHUMIDIFYING CAPACITY 10 L/day (30°C, 80%RH)
POWER SOURCE Single Phase 220-240V/50Hz
POWER CONSUMPTION 210 W
OPERATING CURRENT 0.95 A
OPERATING TEMP. RANGE 5°C ~ 35°C
DIMENSIONS (W×H×D) 290 ×478 ×190 mm
WEIGHT 8.6kg
COMPRESSOR ROTARY
REFRIGERANT R-134a / 92g
GWP 1430
NOTE: Dehumidifying capacity will vary according to temperature
and humidity of the room.
CONTAINS FLUORINATED GREENHOUSE GASES COVERED BY
THE KYOTO PROTOCOL.
HERMETICALLY SEALED SYSTEM
GWP information (according to (EC) No 517 / 2014
3
ENGLISH

4
ENGLISH
LIMITED WARRANTY
TOYOTOMI CO., LTD. (“TOYOTOMI”) warrants each product
and any parts thereof sold by it to be free from defects in mate-
rials or workmanship under normal use and service for
TWENTY FOUR (24) MONTHS from the date of delivery to the
original purchaser at retail subject to the following terms and
conditions:
WHAT IS COVERED: Product or any parts thereof which are
defective in materials or workmanship.
WHAT IS NOT COVERED:
This warranty does not extend to any defect due to the negli-
gence of others; failure to install, operate or maintain unit in ac-
cordance with instructions (operating and maintenance instruc-
tions are furnished with each new unit); unreasonable use, ac-
cidents, alteration, use of unauthorized or non-standardized
TOYOTOMI parts and accessories; electrical malfunction, i.e.,
as resulting from large power surges, short circuit, etc.; incor-
rect installation; or repair by anyone other than a service facility
specified by TOYOTOMI.
WHO IS COVERED: The original purchaser at retail.
WHAT WE WILL DO: TOYOTOMI will either repair or replace, at
its opinion, all defective parts free of charge that are covered
by this limited warranty on a carry-in basis, to your nearest au-
thorized dealer or distributor of TOYOTOMI.
WHAT YOU MUST DO FOR WARRANTY SERVICE: You must
return the defective Product or part to any authorized dealer or
distributor of TOYOTOMI with this LIMITED WARRANTY. If ser-
vice is not available locally, please contact our CUSTOMER
RELATIONS DEPARTMENT at:
TOYOTOMI EUROPE SALES B.V.
E-MAIL: [email protected]
INTERNET: www.toyotomi.eu
THE FOREGOING EXPRESS ALL OF TOYOTOMI’S
OBLIGATIONS AND LIABILITIES WITH RESPECT TO THE
QUALITY OF PRODUCT FURNISHED BY IT. ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY OR FIFTNESS FOR A
PARTICULAR PURPOSE ARE DISCLAIED. TOYOTOMI SHALL
NOT BE LIABLE FOR THE LOSS OF USE OF THE PRODUCT,
INCONVENIENCE, LOSS OR ANY OTHER DAMAGES, DIRECT
OR CONSEQUENTIAL ARISING OUT OF, THE USE OF, OR
INABILITY TO USE, THE PRODUCT OR DAMAGES
RESULTING FROM OR ATTRIBUTABLE TO DEFFECTS IN THE
PRODUCT.
No other than TOYOTOMI has authority to extend or modify
the terms of this Limited Warranty in any manner whatsoever.
Some states do not allow the exclusion or limitation of inciden-
tal or consequential damages or limitations on how long an im-
plied warranty lasts, so these limitations or exclusions may not
apply to you. This Limited Warranty gives you specific legal
rights and you may also have other rights which vary from state
to state.

Rev. 04/17
TOYOTOMI CO., LTD.
5-17, Momozono-cho, Mizuho-ku,
Nagoya, 467-0855 Japan
www.toyotomi.jp Printed in P.R.C.
COMPRESSOR TYPE DEHUMIDIFIER
DÉSHUMIDIFICATEUR D’AIR
LUFTENTFEUCHTER
LUCHTONTVOCHTIGER
DEUMIDIFICATORE
DESHUMIDIFICADOR
DESUMIDIFICADOR
AFFUGTER
LUFTAVFUKTARE AV
KOMPRESSORTYP
OPERATING MANUAL ENGLISH P. 1
MANUAL D’UTILISATION FRANÇAIS P. 5
BEDIENUNGSANLEITUNG DEUTSCH P. 9
GEBRUIKSAANWIJZING NEDERLANDS P.13
MANUALE DI ISTRUZIONI ITALIANO P.17
MANUAL DE INSTRUCCIONES ESPAÑOL P.21
MANUAL DE INSTRUÇÕES PORTUGUÊS P.25
BETJENINGSVEJLEDNING DANSK P.29
BRUKSANVISNING SVENSKA P.33
TD-C210
Other manuals for TD-C210
1
Table of contents