TPI 365 User manual

365
Thermometer
Instruction Manual

A. INTRODUCTION
1. Congratulations!!
Thank you for purchasing TPI products. The 360 series
thermometers are easy to use and built to last. They are
backed by a 3 year limited warranty. Please remember to
complete and return your product warranty registration
card.
2. Product Description
The ergonomically designed 360 series hand-held ther-
mometers are waterproof and offer high accuracy and
reliability.
TABLE OF CONTENTS
A. INTRODUCTION
1. Congratulations ................................3
2. Product Description..........................3
3. Declaration of Conformity ................4
B. SAFETY CONSIDERATIONS ......................5
C. TECHNICAL DATA
1. Features and Benefits........................6
2. Product Applications ........................6
3. Specifications....................................7
D. MEASUREMENT TECHNIQUES
1. Controls and Functions ....................8
2. Performing Measurements............. 9
E. OPTIONAL ACCESORIES ........................10
F. TROUBLESHOOTING & MAINTENANCE 11
23

A. INTRODUCTION
1. Congratulations!!
Thank you for purchasing TPI products. The 360 series
thermometers are easy to use and built to last. They are
backed by a 3 year limited warranty. Please remember to
complete and return your product warranty registration
card.
2. Product Description
The ergonomically designed 360 series hand-held ther-
mometers are waterproof and offer high accuracy and
reliability.
TABLE OF CONTENTS
A. INTRODUCTION
1. Congratulations ................................3
2. Product Description..........................3
3. Declaration of Conformity ................4
B. SAFETY CONSIDERATIONS ......................5
C. TECHNICAL DATA
1. Features and Benefits........................6
2. Product Applications ........................6
3. Specifications....................................7
D. MEASUREMENT TECHNIQUES
1. Controls and Functions ....................8
2. Performing Measurements............. 9
E. OPTIONAL ACCESORIES ........................10
F. TROUBLESHOOTING & MAINTENANCE 11
23

B. SAFETY CONSIDERATIONS
WARNING: Use caution when performing mea-
surements on temperatures above 100ºF.
GENERAL GUIDELINES
ALWAYS
• Test your thermometer before using it to make sure it is
operating properly.
• Inspect temperature probes before using to make sure
there are no breaks or shorts.
• Double check all connections before testing.
NEVER
• Insert the probe into an electrically charged medium.
• Touch the probe tip or shaft after it has been inserted in
a hot substance.
3. EC Declaration of Conformity
This is to certify that TPI 360 series thermometers con-
form to the protection requirements of the council direc-
tive 89/336/EEC, in the approximation of laws of the
member states relating to Electromagnetic compatibility
and 73/23/EEC. The Low Voltage Directive by application
of the following standards:
EN 50081-1 1992 Emissions Standard
EN 50082-1 1992 Immunity Standard
EN 61010-1 1993 Safety Standard
EN 61010-2-031 1995 Safety Standard
EN 61010-2-032 1995 Safety Standard
To ensure conformity with these standard, this instru-
ment must be operated in accordance with the instruc-
tions and specifications given in this manual.
CAUTION: Even though this instrument complies with
the immunity standards, it’s accuracy can be affected
by strong radio emissions not covered in the above
standards. Sources such as hand-held radio trans-
ceivers, radio and TV transmitters, vehicle radios and
cellular phones generate electromagnetic radiation
that could be induced into the test leads of this instru-
ment. Care should be taken to avoid such situations or
alternatively, check to make sure that the instrument is
not being influence by these emissions.
CAUTION: Please follow manufacturers test proce-
dures whenever possible. Do not attempt to measure
unknown voltages or components until a complete
understanding of the circuit is obtained.
4 5

B. SAFETY CONSIDERATIONS
WARNING: Use caution when performing mea-
surements on temperatures above 100ºF.
GENERAL GUIDELINES
ALWAYS
• Test your thermometer before using it to make sure it is
operating properly.
• Inspect temperature probes before using to make sure
there are no breaks or shorts.
• Double check all connections before testing.
NEVER
• Insert the probe into an electrically charged medium.
• Touch the probe tip or shaft after it has been inserted in
a hot substance.
3. EC Declaration of Conformity
This is to certify that TPI 360 series thermometers con-
form to the protection requirements of the council direc-
tive 89/336/EEC, in the approximation of laws of the
member states relating to Electromagnetic compatibility
and 73/23/EEC. The Low Voltage Directive by application
of the following standards:
EN 50081-1 1992 Emissions Standard
EN 50082-1 1992 Immunity Standard
EN 61010-1 1993 Safety Standard
EN 61010-2-031 1995 Safety Standard
EN 61010-2-032 1995 Safety Standard
To ensure conformity with these standard, this instru-
ment must be operated in accordance with the instruc-
tions and specifications given in this manual.
CAUTION: Even though this instrument complies with
the immunity standards, it’s accuracy can be affected
by strong radio emissions not covered in the above
standards. Sources such as hand-held radio trans-
ceivers, radio and TV transmitters, vehicle radios and
cellular phones generate electromagnetic radiation
that could be induced into the test leads of this instru-
ment. Care should be taken to avoid such situations or
alternatively, check to make sure that the instrument is
not being influence by these emissions.
CAUTION: Please follow manufacturers test proce-
dures whenever possible. Do not attempt to measure
unknown voltages or components until a complete
understanding of the circuit is obtained.
4 5

7
3. Specifications
Input Type Range
K-Type Thermocouple -328ºF to 1,112ºF (-200ºC to 600ºC)
K-Type Connection Sub-mini
Accuracy +/-(0.1% of reading + 0.4ºF (0.2ºC))
Resolution > -100ºC = 0.1ºC, < 100ºC = 1ºC
IP Rating IP 67
Units of Measure ºC / ºF Selectable
Operating Temperature -4ºF to 122ºF (-20ºC to 50ºC)
-100ºC = 0.1ºC, < 100ºC = 1ºC
Battery Type AA (LR6) x 2
Battery Life Up to 14,000 hours
Auto Power Off Off after 5 minutes
Connector Type Subminiature Thermocouple
C. TECHNICAL DATA
1. Features and Benefits
Large LCD Easy to read measurement results
High Accuracy Reliable test results.
Water Proof Rugged and built to last.
Auto Off Automatically powers off after
30 minutes of inactivity.
2. Product Applications
Perform the following tests and/or measurements with
the 360 series thermometers:
Validate the temperature of incoming food product
prior to accepting deliveries.
Measure food storage temperature.
Verify cooking and storage temperature.
Confirm hot and cold holding cabinet temperatures.
Measure food reheating temperatures.
Monitor frozen food thawing temperature.
6

7
3. Specifications
Input Type Range
K-Type Thermocouple -328ºF to 1,112ºF (-200ºC to 600ºC)
K-Type Connection Sub-mini
Accuracy +/-(0.1% of reading + 0.4ºF (0.2ºC))
Resolution > -100ºC = 0.1ºC, < 100ºC = 1ºC
IP Rating IP 67
Units of Measure ºC / ºF Selectable
Operating Temperature -4ºF to 122ºF (-20ºC to 50ºC)
-100ºC = 0.1ºC, < 100ºC = 1ºC
Battery Type AA (LR6) x 2
Battery Life Up to 14,000 hours
Auto Power Off Off after 5 minutes
Connector Type Subminiature Thermocouple
C. TECHNICAL DATA
1. Features and Benefits
Large LCD Easy to read measurement results
High Accuracy Reliable test results.
Water Proof Rugged and built to last.
Auto Off Automatically powers off after
30 minutes of inactivity.
2. Product Applications
Perform the following tests and/or measurements with
the 360 series thermometers:
Validate the temperature of incoming food product
prior to accepting deliveries.
Measure food storage temperature.
Verify cooking and storage temperature.
Confirm hot and cold holding cabinet temperatures.
Measure food reheating temperatures.
Monitor frozen food thawing temperature.
6

9
8
2. Performing Measurements
1. Turn the 365 on by pressing the On/Off key. The unit of measure
can be selected at this time. To change units of measure, press and
hold down the On / Off key at the time of power on. The display will
show the unit of measure in the upper right corner of the display.
Once selected, the unit of measure will remain the same after power
off.
After power on, the display will read “OPEN” if no probe is attached.
2. Attach a temperature probe to the input connector observing the
proper polarity.
3. Touch or insert the probe into the item under test.
4. The temperature measured at the probe will display on the 365.
D. Measurement Techniques
1. Controls & Functions
LCD Display
Input Connector
On / Off Key
On / Off Key turns the 365 on for use or off. This
button is also used to select between ºC and ºF
units of measure.
To change units of measure, press and hold
down the On / Off key at the time of power on.
The display will show the unit of measure in the
upper right corner of the display.

9
8
2. Performing Measurements
1. Turn the 365 on by pressing the On/Off key. The unit of measure
can be selected at this time. To change units of measure, press and
hold down the On / Off key at the time of power on. The display will
show the unit of measure in the upper right corner of the display.
Once selected, the unit of measure will remain the same after power
off.
After power on, the display will read “OPEN” if no probe is attached.
2. Attach a temperature probe to the input connector observing the
proper polarity.
3. Touch or insert the probe into the item under test.
4. The temperature measured at the probe will display on the 365.
D. Measurement Techniques
1. Controls & Functions
LCD Display
Input Connector
On / Off Key
On / Off Key turns the 365 on for use or off. This
button is also used to select between ºC and ºF
units of measure.
To change units of measure, press and hold
down the On / Off key at the time of power on.
The display will show the unit of measure in the
upper right corner of the display.

11
10
F. Troubleshooting and Maintenance
Troubleshooting
Problem Probable Causes
Does not power up
• Dead or defective battery
• Broken wire from battery
snap to PCB
Temperature reads
• Very weak battery that will
high
not turn on the low battery
indicator on the LCD
Only reads OPEN
• Temperature probe not connected
• Temperature probe defective
Maintenance
1. Battery Replacement: The 365 will display a battery symbol
when the internal 1.5 Volt batteries needs replacement.
a. Disconnect the temperature probe.
b. Loosen the 4 battery cover screws located on the back
cover.
c. Remove the battery cover.
d. Remove old batteries and replace with new batteries.
Observe the correct polarity.
e. Reassemble the instrument in reverse order from above.
2. Cleaning your 365:
Use a mild detergent and slightly damp cloth to clean the sur-
faces of the 365.
E. Optional Accessories:
Part Number Description
A365 Belt clip holder
GK11M Bead type probe (non-food applications)
GK13M Bead type probe (food and non-food applications)
CK11M Surface temperature measurements
FK 11M Penectration / Immersion measurements
This is a partial listing of temperature probes available for the 365.
Please visit www.tpi-thevalueleader.com for additional probes.

11
10
F. Troubleshooting and Maintenance
Troubleshooting
Problem Probable Causes
Does not power up
• Dead or defective battery
• Broken wire from battery
snap to PCB
Temperature reads
• Very weak battery that will
high
not turn on the low battery
indicator on the LCD
Only reads OPEN
• Temperature probe not connected
• Temperature probe defective
Maintenance
1. Battery Replacement: The 365 will display a battery symbol
when the internal 1.5 Volt batteries needs replacement.
a. Disconnect the temperature probe.
b. Loosen the 4 battery cover screws located on the back
cover.
c. Remove the battery cover.
d. Remove old batteries and replace with new batteries.
Observe the correct polarity.
e. Reassemble the instrument in reverse order from above.
2. Cleaning your 365:
Use a mild detergent and slightly damp cloth to clean the sur-
faces of the 365.
E. Optional Accessories:
Part Number Description
A365 Belt clip holder
GK11M Bead type probe (non-food applications)
GK13M Bead type probe (food and non-food applications)
CK11M Surface temperature measurements
FK 11M Penectration / Immersion measurements
This is a partial listing of temperature probes available for the 365.
Please visit www.tpi-thevalueleader.com for additional probes.

365 SPECIFICATIONS
Input Type Range
K-Type Thermocouple -328ºF to 1,112ºF (-200ºC to 600ºC)
Accuracy +/-(0.1% of reading + 0.4ºF (0.2ºC))
Resolution > -100ºC = 0.1ºC, < 100ºC = 1ºC
IP Rating IP 67
Units of Measure ºC / ºF Selectable
Operating Temperature -4ºF to 122ºF (-20ºC to 50ºC)
Battery Type AA (LR6) x 2 -100ºC = 0.1ºC, < 100ºC = 1ºC
Battery Life Up to 14,000 hours
Auto Power Off Off after 5 minutes
Test Products International, Inc.
9615 SW Allen Blvd., Ste. 104
Beaverton, OR USA 97005
503-520-9197 • Fax: 503-520-1225
info@tpi-thevalueleader.com
L270M • 1/25/05 copyright © 2005 Test Products International, Inc.
Table of contents