Features and presentations liable to changes without notice. Ref.UG-040801-E1, 2020/01 edition.
Preamble
This notice includes all the advice and warnings that enables a correct set up and a safe use of the product.
TPLVision can not be responsible for the bad use of the notice. If so, TPL Vision cancels the guarantee’s effects.
risk class
The EN-62471 norm about lighting uxes enables the classication of led lightings in 4 distinct groups, according to their
hazardousness degree. Please nd below an indicative table, recapitulating the classes of risk for our standard products.
Colour Class Risk
White WHI, Green 525 nm, Red 630 nm 0none
UV 405 nm, Blue 470 nm, IR 850 nm 1low
UV 365 nm 2moderate
UV 385 nm 3high
In all cases, TPL Vision recommends
the use of the protection glasses
that are listed in its catalog.
For more information about photo-
biological risks, do not hesitate to
contact us.
User secUrity
Do respect the power supply voltages and the connection terminals.
Do not modify or dismantle all or part of the product.
Do not connect or clean when power is on.
Do not watch the lighting source directly, and follow the advice below :
• If the workstation enables it, interpose a lter that will stop the lighting radiation under xed or adjustable
frame between the source and the operator.
• When these measures cannot be implemented, supply the operators with glasses (class 4) available for sale at
TPLVision, or with a dedicated protective mask, that will stop the lighting radiation.
• Forbid or limit the direct access to the lighting source (exposure into the radiation axis).
• Establish a security perimeter so as to prevent the operators from approaching the lighting source beyond
therecommendations of the manufacturer, as for eye irritation is concerned.
• In any case, ensure that the chosen means properly reduce the exposition quantities (features of screens or
glasses to be chosen, according to the wavelengths that the operators are exposed to).
eqUiPment maintenance
CLEANING (when the product is switched off)
Please use a soft and dry cloth. Do not use any abrasive material.
Do not use any cleaning solvent or aggressive chemical product.
TPL Vision recommends to use isopropyl alcohol.
UnPacking
Products are packed in our factory, using suitable materials for a safe transport through the usual means of transpor-
tation, in France and internationally. However, a damaged package must be reported to the carrier on delivery. Hand-
written reservations must be indicated on the delivery order. Moreover, please send a letter or an email to TPL Vision as
soon as possible (up to 24 hours after the delivery). If the transportation damage has not been stipulated on the delivery
order and reported to TPL Vision in time, the package will not be taken back nor exchanged. To open the package, donot
use any cutting blade to avoid damaging the product(s). Please use the delivered accessories, if needed (do not use any
other products or equivalents to replace the delivered accessories).
connection
User gUide
M12 4 male points
In STROBE mode:
STROBE entry = 24 V
or 5V TTL –> light on
STROBE MODE CONNECTION
CONTINUOUS MODE CONNECTION
2
4
black
1
brown
+ 24 V
3GND
blue
NC
white
FRONT VIEW OF THE PRODUCT’S CONNECTOR
Automate + 24 V
1
2
3
4
1
2
3
4
Ground
Strobe / Dimming
+ 24 V
Ground
STROBE/
Dimming
P2/4 P3/4
strobe modedimming
control
0
20%
40%
60%
80%
100%
0%
1 2 3 4 5 6
VOLTS
Entrée Déclenchement
Sortie Éclairage
Triggering input
Light
Potential dimming between 1.5 and 5 Volts.
Above 5 Volts, the product reaches100%
of its lighting power. Power supply : 24V +/-10%
Strobe input : 24V or 5V TTL
1.5 ms 1 ms
fixing
dimensions
Length
(mm)
Height
(mm)
Width
(mm)
A B C
TSPOT4 38 30 28
During the set up, the light has to be switched off
and unplugged. Please use the xing holes designed
for that purpose (see scheme above). We recommend
the using of M3 screws (not supplied) with a tightening
torque from 0.5 to 1.5 Nm. We also recommend the
use of a threadlocker (not supplied) to avoid any risk
of loosening.
+5V or +24V
Toward STROBE
input
From camera
/automate
+24
R1
3k9
R2
1k potentiometer
C1
optional 0.1 uf
capacitor
STROBE
4.898 V maximum output
+5V or +24V
From camera
/automate
0V
Toward STROBE
input
Resistance value
to be adapted
to the automaton.
Max. 4.7 kΩ
external dimming configuration PnP-like automaton outPut nPn-like automaton outPut

Other TPL VISION Spotlight manuals

TPL VISION SCOA55 User manual

TPL VISION

TPL VISION SCOA55 User manual

TPL VISION THIN TSPOT 1 User manual

TPL VISION

TPL VISION THIN TSPOT 1 User manual

Popular Spotlight manuals by other brands

EuroLite PAR-64 Profi Spot user manual

EuroLite

EuroLite PAR-64 Profi Spot user manual

Robert Juliat TIBO 503 manual

Robert Juliat

Robert Juliat TIBO 503 manual

Philips SmartSpot 57976/48/16 Specifications

Philips

Philips SmartSpot 57976/48/16 Specifications

Cameo CLZW600IFULLGS installation instructions

Cameo

Cameo CLZW600IFULLGS installation instructions

Sealey AK435.V3 instructions

Sealey

Sealey AK435.V3 instructions

ADJ COB CANNON WASH User instructions

ADJ

ADJ COB CANNON WASH User instructions

olympia electronics GR-298/60L/90/WP manual

olympia electronics

olympia electronics GR-298/60L/90/WP manual

Philips 579254856 Specifications

Philips

Philips 579254856 Specifications

ETC Source Four LED Series user manual

ETC

ETC Source Four LED Series user manual

Hosen Moving Head Spot user manual

Hosen

Hosen Moving Head Spot user manual

Angelo Decor Pond Building Series quick start guide

Angelo Decor

Angelo Decor Pond Building Series quick start guide

Ryobi P7171 Operator's manual

Ryobi

Ryobi P7171 Operator's manual

MAKSA 44416 Instruction guide

MAKSA

MAKSA 44416 Instruction guide

LIVARNO 375304 2101 Operating and safety information

LIVARNO

LIVARNO 375304 2101 Operating and safety information

Chauvet Pinspot YA-06 user guide

Chauvet

Chauvet Pinspot YA-06 user guide

EuroLite VFL-1200 Follow Spot user manual

EuroLite

EuroLite VFL-1200 Follow Spot user manual

Varytec VP-m20 user manual

Varytec

Varytec VP-m20 user manual

Theben LU 102 HF instruction manual

Theben

Theben LU 102 HF instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.