manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TPL VISION
  6. •
  7. Spotlight
  8. •
  9. TPL VISION THIN TSPOT 4 User manual

TPL VISION THIN TSPOT 4 User manual

TPL VISION UK
Brenchley House – School Road – Charing – Kent TN27 0JW – UK
Tel. +44 (0)1738 310 392 – www.tpl-vision.com
User gUideUser gUide P4/4
Features and presentations liable to changes without notice. Ref.UG-040801-E1, 2020/01 edition.
Preamble
This notice includes all the advice and warnings that enables a correct set up and a safe use of the product.
TPLVision can not be responsible for the bad use of the notice. If so, TPL Vision cancels the guarantee’s effects.
risk class
The EN-62471 norm about lighting uxes enables the classication of led lightings in 4 distinct groups, according to their
hazardousness degree. Please nd below an indicative table, recapitulating the classes of risk for our standard products.
Colour Class Risk
White WHI, Green 525 nm, Red 630 nm 0none
UV 405 nm, Blue 470 nm, IR 850 nm 1low
UV 365 nm 2moderate
UV 385 nm 3high
In all cases, TPL Vision recommends
the use of the protection glasses
that are listed in its catalog.
For more information about photo-
biological risks, do not hesitate to
contact us.
User secUrity
Do respect the power supply voltages and the connection terminals.
Do not modify or dismantle all or part of the product.
Do not connect or clean when power is on.
Do not watch the lighting source directly, and follow the advice below :
• If the workstation enables it, interpose a lter that will stop the lighting radiation under xed or adjustable
frame between the source and the operator.
• When these measures cannot be implemented, supply the operators with glasses (class 4) available for sale at
TPLVision, or with a dedicated protective mask, that will stop the lighting radiation.
• Forbid or limit the direct access to the lighting source (exposure into the radiation axis).
• Establish a security perimeter so as to prevent the operators from approaching the lighting source beyond
therecommendations of the manufacturer, as for eye irritation is concerned.
• In any case, ensure that the chosen means properly reduce the exposition quantities (features of screens or
glasses to be chosen, according to the wavelengths that the operators are exposed to).
eqUiPment maintenance
CLEANING (when the product is switched off)
Please use a soft and dry cloth. Do not use any abrasive material.
Do not use any cleaning solvent or aggressive chemical product.
TPL Vision recommends to use isopropyl alcohol.
UnPacking
Products are packed in our factory, using suitable materials for a safe transport through the usual means of transpor-
tation, in France and internationally. However, a damaged package must be reported to the carrier on delivery. Hand-
written reservations must be indicated on the delivery order. Moreover, please send a letter or an email to TPL Vision as
soon as possible (up to 24 hours after the delivery). If the transportation damage has not been stipulated on the delivery
order and reported to TPL Vision in time, the package will not be taken back nor exchanged. To open the package, donot
use any cutting blade to avoid damaging the product(s). Please use the delivered accessories, if needed (do not use any
other products or equivalents to replace the delivered accessories).
connection
User gUide
M12 4 male points
In STROBE mode:
STROBE entry = 24 V
or 5V TTL –> light on
STROBE MODE CONNECTION
CONTINUOUS MODE CONNECTION
2
4
black
1
brown
+ 24 V
3GND
blue
NC
white
FRONT VIEW OF THE PRODUCT’S CONNECTOR
Automate + 24 V
1
2
3
4
1
2
3
4
Ground
Strobe / Dimming
+ 24 V
Ground
STROBE/
Dimming
P2/4 P3/4
strobe modedimming
control
0
20%
40%
60%
80%
100%
0%
1 2 3 4 5 6
VOLTS
Entrée Déclenchement
Sortie Éclairage
Triggering input
Light
Potential dimming between 1.5 and 5 Volts.
Above 5 Volts, the product reaches100%
of its lighting power. Power supply : 24V +/-10%
Strobe input : 24V or 5V TTL
1.5 ms 1 ms
fixing
dimensions
Length
(mm)
Height
(mm)
Width
(mm)
A B C
TSPOT4 38 30 28
During the set up, the light has to be switched off
and unplugged. Please use the xing holes designed
for that purpose (see scheme above). We recommend
the using of M3 screws (not supplied) with a tightening
torque from 0.5 to 1.5 Nm. We also recommend the
use of a threadlocker (not supplied) to avoid any risk
of loosening.
+5V or +24V
Toward STROBE
input
From camera
/automate
+24
R1
3k9
R2
1k potentiometer
C1
optional 0.1 uf
capacitor
STROBE
4.898 V maximum output
+5V or +24V
From camera
/automate
0V
Toward STROBE
input
Resistance value
to be adapted
to the automaton.
Max. 4.7 kΩ
external dimming configuration PnP-like automaton outPut nPn-like automaton outPut

Other TPL VISION Spotlight manuals

TPL VISION THIN TSPOT 1 User manual

TPL VISION

TPL VISION THIN TSPOT 1 User manual

TPL VISION SCOA55 User manual

TPL VISION

TPL VISION SCOA55 User manual

Popular Spotlight manuals by other brands

ETC ColorSource Spot installation manual

ETC

ETC ColorSource Spot installation manual

Conrad 11 03 89 operating instructions

Conrad

Conrad 11 03 89 operating instructions

Ryobi PCL661 Operator's manual

Ryobi

Ryobi PCL661 Operator's manual

Miboxer SL1-12 quick start guide

Miboxer

Miboxer SL1-12 quick start guide

RICOMAN R096501 installation instructions

RICOMAN

RICOMAN R096501 installation instructions

Renkforce LV-DJ13 operating instructions

Renkforce

Renkforce LV-DJ13 operating instructions

Lumena MINILITE LCBR-MLB12P instructions

Lumena

Lumena MINILITE LCBR-MLB12P instructions

ring 5B11S8 quick start guide

ring

ring 5B11S8 quick start guide

American DJ FS-2500 DMX User instructions

American DJ

American DJ FS-2500 DMX User instructions

Beyond Lighting BY-F600 user manual

Beyond Lighting

Beyond Lighting BY-F600 user manual

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SPOT Installation & maintenance instructions

Clevertronics

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SPOT Installation & maintenance instructions

Equinox Systems Fusion 100 Spot user manual

Equinox Systems

Equinox Systems Fusion 100 Spot user manual

Larson Electronics HUL-P10WR-DM-ILS-1227 quick start guide

Larson Electronics

Larson Electronics HUL-P10WR-DM-ILS-1227 quick start guide

Flipo WTT-1011 instructions

Flipo

Flipo WTT-1011 instructions

Chauvet COLORado 1 user manual

Chauvet

Chauvet COLORado 1 user manual

Century DOBI DOBIG-154530 manual

Century

Century DOBI DOBIG-154530 manual

Universal LITE AIDE HE-430 owner's manual

Universal

Universal LITE AIDE HE-430 owner's manual

ANSMANN POWERLIGHT 5.1 instructions

ANSMANN

ANSMANN POWERLIGHT 5.1 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.