6
J/RS232-xx-01
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Technical Specifications
For use with Transition Networks Model J/RS232-xx-01 or equivalent
Data Rate 120 Kb/s, asynchronous
Dimensions 3.0" x 3.9" x 1.0" (76 mm x 99 mm x 25 mm)
Shipping Weight 6 oz. (181 g) (approximately)
Power Consumption 3 Watts
Power Supply 12 VDC, 0.5 A (North America)
12 VDC, 0.41 A (Europe, Japan, Latin America)
12 VDC, 1.25 A (N. Z., Australia, U.K., South Africa)
(The external power supply provided with this product
is UL listed by the power supply’s manufacturer.)
MTBF (approximate) 49,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
129,000 hours (Bellcore7 V5.0)
Environment Tmra*: 0 to 50°C (32° to 122°F )
Storage Temp: -15° to 65°C (5° to 149°F)
Humidity: 5 to 95%, non condensing
Altitude: 0 to 10,000 feet
Warranty Lifetime
*Manufacturer’s rated ambient temperature.
The information in this user’s guide is subject to change. For the most up-to-date
information on the J/RS232-xx-01 media converter, view the user’s guide on-line
at: www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not stare into
the beam or view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
7
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:
1. Is the PWR (power) LED on the media converter illuminated?
NO
• Is the power adapter the proper type of voltage and cycle frequency
for the AC outlet? (See “Technical Specifications” on page 6.)
• Is the power adapter properly installed in the media converter and in
the AC outlet?
• Does the grounded AC outlet provide power?
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 2.
2. Is the RX (RS-232) LED illuminated?
NO
• Check the RS-232 cable for proper connection.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 3.
3. Is the FL (fiber) LED illuminated?
NO
• Check the fiber cables for proper connection.
• Verify that the TX and RX cables on the media converter are
connected to the RX and TX ports, respectively, on the remote media
converter.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
Contact Us
Technical support is available 24 hours a day.
US and Canada: 1-800-260-1312
International: 00-1-952-941-7600
Chat live via the Web with Transition Networks Technical Support.
Log onto www.transition.com and click the Transition Now link.
Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.
Ask a question anytime by sending an e-mail to our technical support staff.
Transition Networks; 6475 City West Parkway; Minneapolis, MN 55344, USA
telephone: 952-941-7600; toll free: 800-526-9267; fax: 952-941-2322