TriangleTube GPX Series Use and care manual

OWNER'S RECORD
Please complete for future reference.
Model #
_______________________
Serial #
________
Purchased from
________________________________
Date Purchased
_______________________________
T
M
TRIANGLE ENGINEERING
OF ARKANSAS, INC.
1101 North Redmond Road •Jacksonville, Arkansas 72076
(501) 982-7558 •Fax (501) 982-5691 • 1-800-255-9014
FOR MODELS:
GPX 1210
GPX 1611
GPX 2011
GPX 2413
GPX 3013
October 2016
Installation •Operation •Repair parts
I
OWNER’S
MANUAL
Read and
save these
instructions

ed) wiring must be used. DO NOT USE
AN EXTENSION CORD.
• To avoid risk of fire, electrical shock
and other injuries, switch power off
at service panel and tag prior to the
installation.
• Do not operate fan in areas where gas
or oil-fired equipment is in operation.
• Wear safety goggles when drilling,
hammering, or cutting materials.
OPERATING YOUR FAN
IMPORTANT Do not operate your fan
without first providing adequate ven-
tilation (such as a door or window) to
provide the proper inlet airflow.
WARNING BEFORE PROCEEDING
WITH THE INSTALLATION, SWITCH
POWER OFF AT SERVICE PANEL. The
fan requires a 120-volt AC power source
with at least 5-amp capacity (10-amp for
24" and 30" GPX). All electrical work
must be done in accordance with local
building codes, using approved mate-
rial. Follow the wiring diagram shown
on next page.
ITEMS REQUIRED FOR INSTALLATION
• Screwdriver • Straight edge
• Safety goggles • Pencil
• Measuring tape
• Electric drill
• Power saw or hand saw
• (12) wood screws 1/4" x
3/4
" lg.
GPX FANS ARE EASY TO INSTALL:
1. Simply cut a square opening in the
wall. (See chart below).
2. Slide the fan into the opening from
outside the structure. Using (12)
1
/
4
"
x
3
/
4
" screws, attach flange to your
structure.
3. Connect the motor to a 120-volt,
60-Hz single-phase power source.
Proper installation is required to
achieve maximum efficiency. It is nec-
essary to provide adequate ventilation
to meet minimum intake air require-
ments. This prevents pressure buildup,
which will reduce the fan's efficiency.
Inadequate intake air can also lead to
premature motor failure.
CAUTION - SAFETY RULES
WARNING: TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK OR INJURY,
OBSERVE THE FOLLOWING:
• Use this unit only in the manner
intended by the manufacturer. If you
have questions, please contact manu-
facturer.
• Before servicing or cleaning unit,
switch power off at service panel and
tag service panel to prevent power
from being switched on accidentally.
• Installation and electrical wiring must
be done by qualified person(s) in
accordance with all applicable codes
and standards, including fire-rated
construction.
• Sufficient air is needed for proper
combustion and exhausting of gasses
through the flue (chimney) of fuel-
burning equipment to prevent back-
drafting. Follow the heating equipment
manufacturer's guidelines, along with
safety standards such as those pub-
lished by the National Fire Protection
Agency (NFPA), the American Society
for Heating, Refrigeration & Air
Conditioning Engineers (ASHRAE),
and your local code authorities.
• CAUTION Check for hidden electrical
wiring or utility lines before cutting or
drilling into a wall or ceiling.
• CAUTION For general ventilating only.
DO NOT use to exhaust hazardous or
explosive materials.
• Your GPX fan will operate only on 120
volt AC, 60Hz (cycle) current.
• A permanent, THREE-WIRE (ground-
IMPORTANT: READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING
TO INSTALL, OPERATE OR SERVICE THIS FAN.
FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
Model Wall Hole Size
12 17
3
/
8
" square
16 21
3
/
8
" square
20 25
3
/
8
" square
24 29
3
/
8
" square
30 35
3
/
8
" square

Shutter Assembly
Blade Assembly
Housing
Screen Guard
M
otor
REPAIR PARTS
When ordering repair parts, always
give the following information:
1. Model Number
2. Serial Number
3. Part Description
GPX
Fan Motor
Green Ground Screw
Green
White White
BlackBlack 120V, 60Hz
Single Phase
Power Supply
Use wire nuts
suitable for wire size.
(2) required
WIRING DIAGRAM
A B C D Weight
Model
Square Square LBS.
GPX 1210 18
3
⁄
4
" 17
1
⁄
8
" 6" 13
1
⁄
4
" 35
GPX 1611 22
3
⁄
4
" 21
1
⁄
8
" 6" 13" 43
GPX 2011 26
3
⁄
4
" 25
1
⁄
8
" 6" 13" 55
GPX 2413 30
3
⁄
4
" 29
1
⁄
8
" 6" 14
1
⁄
4
" 66
GPX 3013 36
3
⁄
4
" 35
1
⁄
8
" 6" 13" 70
HOUSING DIMENSIONS
WARNING: TO REDUCE THE RISK OF FIRE OR
ELECTRICAL SHOCK DO NOT USE THIS FAN WITH
ANY SOLID STATE FAN SPEED CONTROL DEVICE.

LIMITED ONE YEAR WARRANTY
NOTE: Turning fan on and off in rapid succession will cause motor to over heat. If this occurs allow motor to cool
twenty minutes before resuming operation.
Specifications subject to change without notice
MOTOR REPLACEMENT DURING WARRANTY PERIOD.
If the motor on your General Exhaust Fan should fail during the first year of operation, simply remove
the LABEL ONLY from the motor and mail to Triangle Engineering, via certified or registered mail.
Once the label is received, and if the motor is still under warranty, we will ship a new motor, UPS
PREPAID.
DO NOT RETURN MOTOR.
Triangle Engineering of Arkansas, Inc. (Manufacturer) warrants, from the date of purchase, to the origi-
nal purchaser only, that the product manufactured by Manufacturer is free from defects in material and
workmanship for a period of ONE (1) YEAR. Motors, capacitors, v-belts and switches are excluded from
this warranty, but shall have a limited one year warranty from date of purchase to the original purchaser.
If a failure of the product occurs, contact the Manufacturer at: 1-800-255-9014 and give the model
number of the product, the purchase date, and a description of the problem to the customer service
agent.
Once the problem is diagnosed, and proof of purchase date is verified, Manufacturer will have the
option of shipping the necessary repair part(s) to the Customer, freight prepaid or having the product
returned to Manufacturer for repair or replacement. If the product is returned to the Manufacturer,
Customer is responsible for prepayment of all inbound freight charges. Upon repair or replacement,
which shall be at the discretion of Manufacturer, the Manufacturer will prepay all outbound freight
charges for the return of the product to the customer. However, if Manufacturer finds product to be
in operating condition and no problems are diagnosed, product will be returned to customer freight
collect.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.
Except as provided by this express warranty, the goods are sold “as is” without any implied warran-
ties.
This limited warranty does not cover labor to replace warrantied parts or motors, nor does it cover
failure of the installer to provide adequate ventilation to meet minimum exhaust requirements, damage
resulting from accident, misuse or abuse, lack of proper maintenance, improper installation, affixing of
any parts or attachments not authorized by Manufacturer, or loss of parts.
In no event shall Manufacturer be liable for any special, incidental, or consequential damages; which
may result from any defect in material or workmanship.
It is expressly understood that Buyer’s sole and exclusive remedy shall be repair or replacement of defec-
tive parts, and that Triangle Engineering shall not be liable for injury to persons or property. Should the goods
prove so defective, however, as to preclude the remedying of warranted defects by repair or replacement,
the Buyer’s sole and exclusive remedy shall then be a refund of the purchase price.
This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.
TROUBLESHOOTING
Symptom Possible Cause Corrective Action
Fan does not operate
Defective Motor Repair or replace motor
No power Inspect power cord for damage.
Check fuse or circuit breaker
Insucient airflow
Intake Guard is excessively
dirty Clean guards.
Shutter is blocked or not
operating Check shutter for proper operation
Insucient airflow Open window or door.
Squealing, Slapping or
Whining noises while
operating
Defective motor bearings Replace motor
Damaged Blade Replace fan blade
This manual suits for next models
5
Table of contents
Other TriangleTube Fan manuals
Popular Fan manuals by other brands

SALCO
SALCO STW-1001 TITANO manual

Maxxima
Maxxima Luvoni MEW-VF170 Installation and care guide

Qazqa
Qazqa Vifte instruction manual

Ruck
Ruck AIR MOVEMENT Prime Evo Assembly instruction

Honeywell
Honeywell QUIETSET HY-254 Series owner's manual

AGI
AGI KEHO ATS-803 Series Installation, operation, and parts manual