SUPPLEMENTAL SHEET
LOCAL AIR CONDITIONER
2 EN
local air conditioner PAC 4600
PAC 4600 Disconnecting and connecting the
connection lines
Info
On the product page of the PAC 4600, we will also
provide a video in which we explain how to disconnect
or connect the connection lines and what to observe
for this process:
https://hub.trotec.com/?id=43770
Danger
Flammable difluoromethane refrigerant (R32)!
During installation or maintenance, keep ignition
sources such as open flames, an active gas appliance
or an electric heater away from the working
environment.
Warning
The device must be disconnected from the mains
during the entire procedure! It may only be taken back
into operation, when all connections have been re-
established and checked. The fastenings and all covers
must have been reattached beforehand.
Note
Leaking refrigerant contributes to climate change.
Refrigerants with a lower global warming potential
have a smaller impact in the event of leakage. This
device contains refrigerant with a global warming
potential of 675. What this means is that should 1kg of
this refrigerant escape, it's effect on global warming
will be 675times greater than that of 1kg of CO2 –
referring to a period of 100years. Do not perform any
work on the refrigerant circuit and do not disassemble
the device– always consult specialist staff.
The connection line can be guided outside through a door or
window left ajar. The connection line can be disconnected from
the external unit, permitting you to install it through a wall
opening (Ø min. 60mm). Observe the following information
when installing the connection line:
• The connection line must never be jammed or kinked.
• The connection line must not be subjected to tension or
other mechanical stress.
• The pipe insulation and the protective cover must not be
damaged.
Information on disconnecting and connecting the
connection line:
• The lines may only be disconnected and connected by a
certified specialist company for cooling and air-
conditioning.
• Only disconnect the devices immediately before assembly
and reconnect them as soon as possible.
• Before connecting the lines once more, it must be ensured
that there is no dirt, moisture or any other foreign objects
which could impair the screw connections.
• Make sure to attach the fastening clip once the lines have
been connected.
• Provided all tasks are performed properly, the device may
disconnected and reconnected several times without
experiencing any noteworthy loss of cooling capacity.
Info
In order to connect the condensation hose you require
a hose connection. This article can be ordered free of
charge from Trotec as accessory
(article number:7.310.000.346).
Please proceed as follows to disconnect the connection lines:
üThe device is switched off.
üThe device is disconnected from the mains.
üThe open-end wrenches SW21 and SW24 are ready for
use.
üA wire cutter (e.g. standard size140mm) is ready for use.
1. Remove the screws(1) at the rear of the external unit.
2. Remove the cover(2) from the device.
1
1
2
EN 3
local air conditioner PAC 4600
3. Unscrew the left and right-hand union nut by means of the
supplied open-end wrench(SW24). Apply the other open-
end wrench(SW21) to the part of the coupling to counter
it.
ðScrew constantly until the connection is disconnected.
ðIt is possible that refrigerant leaks out while hissing
sounds occur.
SW 24
SW 21
4. Disconnect both hoses from each other.
5. If the hose connection is not installed, cut the transparent
condensation drain hose(3) with a wire cutter. To be able
to connect the hose ends later on, use the hose
connection(4).
ðPlease note that residual liquid might still be leaking
from the condensation drain hose.
3
4
5
6. Press the lateral link of the plug connection and pull the
plug out of the socket. The plug connection is located
beneath the black bag(5).
7. Unscrew the fastening clip and remove the disconnected
connection lines.
If you want to feed the connection line through a wall opening, it
must have a minimum diameter of 60mm.
After the positioning or assembly of internal and external unit,
the connection line can be connected to the external unit. To do
so, please proceed as follows:
üThe device is switched off.
üThe device is disconnected from the mains.
üThe open-end wrenches SW21 and SW24 are ready for
use.
üA hose connection (article number: 7.310.000.346) is ready
for use.
1. Pass the connection lines into the external unit and fasten
them by means of the fastening clip. In doing so, make
sure that the lines to be connected have a sufficient length.
2. Connect the plug connection and position it beneath the
black bag.
3. Connect the hose ends of the condensation hose with the
hose connection (article number:7.310.000.346).
4. Insert the part of the coupling into the union nut.
5. Unscrew the left and right-hand union nut by means of the
supplied open-end wrench(SW24). Apply the other open-
end wrench(SW21) to the part of the coupling to counter
it.
ðScrew constantly until the connection is firm.
ðIt is possible that refrigerant leaks out while hissing
sounds occur.
SW 24
SW 21
6. Having connected the connection lines, check the screw
connections for tightness by gently shaking the lines.
ðThe screw connections must not be loose, and no
hissing sounds must occur.
7. Place the cover at the rear of the external unit.
8. Fasten the cover with the screws.
Trotec GmbH
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
[email protected]
www.trotec.com

Other manuals for PAC 4600

1

This manual suits for next models

1

Other Trotec Air Conditioner manuals

Trotec PAC 5800 X User manual

Trotec

Trotec PAC 5800 X User manual

Trotec pac 2000 e User manual

Trotec

Trotec pac 2000 e User manual

Trotec Airlock 100 User manual

Trotec

Trotec Airlock 100 User manual

Trotec PAC 3550 PRO User manual

Trotec

Trotec PAC 3550 PRO User manual

Trotec PT 6500 S User manual

Trotec

Trotec PT 6500 S User manual

Trotec PAC 3550 PRO User manual

Trotec

Trotec PAC 3550 PRO User manual

Trotec PT 2000 SP User manual

Trotec

Trotec PT 2000 SP User manual

Trotec PAC-W 2200 S User manual

Trotec

Trotec PAC-W 2200 S User manual

Trotec PAE60 User manual

Trotec

Trotec PAE60 User manual

Trotec PortaTemp 4500 User manual

Trotec

Trotec PortaTemp 4500 User manual

Trotec pac 2000 e User manual

Trotec

Trotec pac 2000 e User manual

Trotec PAE 35 HEPA User manual

Trotec

Trotec PAE 35 HEPA User manual

Trotec PAE 25 User manual

Trotec

Trotec PAE 25 User manual

Trotec PT 2700 SP User manual

Trotec

Trotec PT 2700 SP User manual

Trotec PAE 49 User manual

Trotec

Trotec PAE 49 User manual

Trotec PAC 2100 X User manual

Trotec

Trotec PAC 2100 X User manual

Trotec PAC 3200 E A+ User manual

Trotec

Trotec PAC 3200 E A+ User manual

Trotec PAE 19 H User manual

Trotec

Trotec PAE 19 H User manual

Trotec PAC 2000 S User manual

Trotec

Trotec PAC 2000 S User manual

Trotec PAC 2000 SH User manual

Trotec

Trotec PAC 2000 SH User manual

Trotec PAC 4600 User manual

Trotec

Trotec PAC 4600 User manual

Trotec PAC-W 2600 SH User manual

Trotec

Trotec PAC-W 2600 SH User manual

Trotec PAC 3500 E User manual

Trotec

Trotec PAC 3500 E User manual

Trotec PAE 10 User manual

Trotec

Trotec PAE 10 User manual

Popular Air Conditioner manuals by other brands

Fujitsu ASYG 09 LLCA installation manual

Fujitsu

Fujitsu ASYG 09 LLCA installation manual

York HVHC 07-12DS Installation & owner's manual

York

York HVHC 07-12DS Installation & owner's manual

Carrier Fan Coil 42B Installation, operation and maintenance manual

Carrier

Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity IDUFCI60KC-3 installation manual

intensity

intensity IDUFCI60KC-3 installation manual

Frigidaire FAC064K7A2 Factory parts catalog

Frigidaire

Frigidaire FAC064K7A2 Factory parts catalog

Sanyo KS2432 instruction manual

Sanyo

Sanyo KS2432 instruction manual

LG MultiV Series installation manual

LG

LG MultiV Series installation manual

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

CLIMAVENETA

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea EWK06CW5 user manual

Midea

Midea EWK06CW5 user manual

Pioneer FAB Series installation manual

Pioneer

Pioneer FAB Series installation manual

SPT WA-1511S user manual

SPT

SPT WA-1511S user manual

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Mitsubishi Electric

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic CS-S18HKQ Service manual

Panasonic

Panasonic CS-S18HKQ Service manual

Panasonic CS-E15NKE3 operating instructions

Panasonic

Panasonic CS-E15NKE3 operating instructions

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Friedrich ZoneAire Compact P08SA owner's manual

Friedrich

Friedrich ZoneAire Compact P08SA owner's manual

Daikin R32 Split Series installation manual

Daikin

Daikin R32 Split Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.