EN 7
local air conditioner PAC 4600
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Set the device up in an upright and stable position.
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are unrolled completely.
• Make sure that the air inlet and outlet are not obstructed.
• Make sure that no curtains or other objects interfere with
the air flow.
Prior to initial start-up, insert the batteries in the remote control.
Internal unit
The internal unit will be installed at the desired location with the
air outlet facing the room whilst observing the minimum
distances.
Connection line
Warning
The device must be disconnected from the mains
during the entire procedure! It may only be taken back
into operation, when all connections have been
re-established and checked. The fastenings and all
covers must have been reattached beforehand.
Note
Leaking refrigerant contributes to climate change.
Refrigerants with a lower global warming potential
have a smaller impact in the event of leakage. This
device contains refrigerant with a global warming
potential of 2088. What this means is that should 1kg
of this refrigerant escape, it's effect on global warming
will be 2088times greater than that of 1kg of CO2 –
referring to a period of 100years. Do not perform any
work on the refrigerant circuit and do not disassemble
the device– always consult specialist staff.
The connection line(5) can be guided outside through a door or
window left ajar. The connection line can be disconnected from
the internal unit, permitting you to install it through a wall
opening (Ø min. 60mm). Observe the following information
when installing the connection line:
• The connection line must never be jammed or kinked.
• The connection line must not be subjected to tension or
other mechanical stress.
• The pipe insulation and the protective cover must not be
damaged.
The connection line(5) is connected to the internal unit by
means of quick couplings. These allow you to disconnect the
connection line from the internal unit for assembly purposes
without the risk of losing refrigerant.
Notes regarding the disconnection of the connection line:
• The lines may only be disconnected and connected by a
certified specialist company for cooling and
air-conditioning.
• Only disconnect the devices immediately before assembly
and reconnect them as soon as possible.
• Before connecting the lines once more, it must be ensured
that there is no dirt, moisture or any other foreign objects
which could impair the proper functioning of the quick
couplings.
• Make sure to attach the fastening clip once the lines have
been connected.
• Provided all tasks are performed properly, the device may
disconnected and reconnected approx. 7times without
experiencing any noteworthy loss of cooling capacity.
Please proceed as follows:
üThe device is switched off.
üThe device is disconnected from the mains.
1. Remove the screws(21) at the rear of the device.
2. Remove the cover(14) from the device.
3. Unscrew the fastening clip(22).
4. Press the lateral link of the plug connection(23) and pull
the plug out of the socket.
5. Remove the upper part of the holder(25) by unscrewing
the two screws.