
EN Operating Manual – Air Conditioner PAC 4700 X 3
Accessories
Note:
• Measuring condition for the above specifications is according
to EN 14511:
– temperature of dry bulb (room temperature) = 35°C
– temperature of wet bulb (relative humidity) = 24°C
• Test condition for the data on the nameplate is as per safety
regulation: EN 60335-2-40
Carefully read the operating manual before using the device
and keep it within reach!
• Do not use the device in potentially explosive rooms.
• Do not use the device in atmospheres containing oil, sulphur,
chlorine or salt.
• Set the device in an upright and stable position.
• Let the device dry out after a wet clean. Do not operate it
when wet.
• Ensure that the air inlet and outlet are not obstructed.
• Ensure that the side of the device where the air inlet is found
is kept free of dirt and loose objects.
• Never insert objects into the device.
• Do not cover or transport the device during operation.
• Ensure that all electric cables outside of the device are pro-
tected from damage (e.g. from animals).
• Only use extensions to the connecting cable which are appro-
priate to the device power consumption, the length of its ca-
ble and its use. Avoid electrical overload.
• Only transport the device in an upright position with an emp-
tied condensation tank or condensation drain hose.
• Dispose of the collected condensation. Do not drink it. There
is a risk of infection!
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Observe the storage and operating conditions (see chapter
Technical data).
Intended use
Only use the device for cooling, ventilating and dehumidifying
room air in closed rooms, while adhering to and following the
technical data.
Improper use
Do not place the device on damp or flooded ground. Do not use
the device outdoors. Do not place any objects, e.g. wet clothing,
on the device for drying. Any unauthorised changes,
modifications or alterations of the device are forbidden.
No. Operating element
10 Exhaust air hose
11 PVC strip – for filling the open window space
12 PVC strip – for filling the open window space
13 PVC strip (with hole) – for filling the open window space and with hole
for connection
14 Outward adaptor – to be put on the hose and inserted into the PVC strip
(or into the hole in the wall/window)
15 Cover for outward adaptor
16 Remote control
17 Activated carbon filter
18 Drain tube for continuous drainage
Technical data
Parameter Value
Model PAC 4700 X
Cooling capacity 4.7 kW
Power consumption for cooling
operation
1800 W / 8.2 A
Air flow rate, max. 550 m3/h
Dehumidifying capacity, max. 1.5 l/h
Power supply 220 to 240 V AC, 50 Hz
Compressor type rotary compressor
Cooling agent R410A
Fan stages 3
Timer 1 to 24 hours
Surrounding conditions cooling: 18 to 32 °C
Exhaust air hose Ø 142 x 1500 mm
Weight 35 kg
Dimensions (WxDxH) 422 mm x 443 mm x 825 mm
Minimum distance
from walls or other objects
A: Top: 36 cm
B: Rear: 36 cm
C: Side: 36 cm
D: Front: 36 cm
Safety