Trotec PAC 5800 X User manual

TRT-BA-PAC5800X-TC-001-EN
PAC 5800 X
EN
OPERATING MANUAL
LOCAL AIR CONDITIONER

1 EN
Operating manual – local air conditioner PAC 5800 X
Table of contents
Notes regarding the operating manual.................................1
Safety .....................................................................................1
Information about the device................................................3
Transport and storage...........................................................4
Assembly and installation.....................................................4
Operation ...............................................................................7
Errors and faults..................................................................12
Maintenance ........................................................................13
Technical annex...................................................................16
Disposal ...............................................................................16
Notes regarding the operating manual
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
operating manual must be observed.
You can download the current version of the operating manual
and the EU declaration of conformity via the following link:
PAC 5800 X
https://hub.trotec.com/?id=41514
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Do not use the device in potentially explosive rooms.
• Do not use the device in aggressive atmosphere.
• Set the device up in an upright and stable position.
• Let the device dry out after a wet clean. Do not operate it
when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Never insert any objects or limbs into the device.
• Do not cover or transport the device during operation.
• Do not sit on the device.
• This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
• Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

EN 2
Operating manual – local air conditioner PAC 5800 X
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The electrical connection must correspond to the
specifications in chapter Technical data.
• Insert the mains plug into a properly secured mains
socket.
• Observe the technical data when selecting extensions to
the power cable. Completely unroll the extension cable.
Avoid electrical overload.
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk.
• When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.
• Ensure that the air inlet and outlet are not obstructed.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Ensure that the side of the device where the air inlet is
found is kept free of dirt and loose objects.
• Only transport the device in an upright position with an
emptied condensation tray or drain hose.
• Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
Intended use
Only use the device for cooling, ventilating and dehumidifying
indoor air whilst adhering to the technical data.
Improper use
• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device outdoors.
• Any unauthorised modifications, such as alterations or
structural changes to the device, are forbidden.
• Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the operating manual, especially
the Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
Do not operate the device without an inserted air filter!
Without an air filter the inside of the device will be
heavily contaminated, which could reduce the
dehumidification performance and result in damage to
the device.
Behaviour in the event of an emergency
1. Switch the device off.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.

3 EN
Operating manual – local air conditioner PAC 5800 X
Information about the device
Device description
The device serves the purpose of cooling the room air. It further
filters and dehumidifies the air thus creating an agreeable room
climate.
The unit cools the room air by withdrawing warmth. The
absorbed warmth is emitted to the outside via the exhaust air
hose; cooled air is fed to the installation site by means of a fan.
Accumulating condensate drips from the evaporator onto the hot
condenser, there it evaporates and then is transported to the
outside via the exhaust air hose.
In ventilation mode the device provides the opportunity of air
circulation without cooling effect.
In dehumidification mode moisture is withdrawn from the air.
The device operates fully automatically and features a variety of
further options. The device can, for instance, be switched on or
off automatically with time delay via the timer function.
Operation of the device is possible either via the control panel at
the device or via the supplied infrared remote control.
The device was designed for universal and flexible application.
Due to its compact dimensions it can be easily transported and
used in all interior spaces.
Device depiction
1
2
1
3
11
12
13
2
4
3
ON/OFF
MODE
SPEED UP
TIMER
SLEEP
DOWN
5
6
6
7
1
8
9
10
No. Designation
1 Air inlet with air filter
2 Transport handle
3 Wheels
4 Water tank
5 Remote control
6 Power cable holder
7 Condensate outlet with sealing cap and rubber stopper
8 Cable storage compartment
9 Exhaust air hose connection
10 Air inlet with air filter and activated carbon filter
11 Air outlet with adjustable ventilation flaps
12 Segment display
13 Control panel

EN 4
Operating manual – local air conditioner PAC 5800 X
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
To make the device easier to transport, it is fitted with wheels.
To make the device easier to transport, it is fitted with a carry
handle.
Before transporting the device, observe the following:
• Switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Drain the remaining condensate from the device.
• Do not use the power cable to drag the device.
• Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
• Set up the device in an upright position after transport.
• Leave the device to rest for 12to24hours, so the
refrigerant can accumulate within the compressor.
Wait 12to24hours before switching the device back on!
Acting contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
Storage
Before storing the device, observe the following:
• Drain the remaining condensate from the device.
When the device is not being used, observe the following
storage conditions:
• dry and protected from frost and heat
• in an upright position where it is protected from dust and
direct sunlight
• with a cover to protect it from invasive dust if necessary
• Place no further devices or objects on top of the device to
prevent it from being damaged.
• Remove batteries from the remote control.
Assembly and installation
Scope of delivery
• 1x Device
• 1 x Exhaust air hose
• 1x Hose adapter
• 1x Hose connector
• 1x Condensation drain hose
• 1x Activated carbon filter
• 1 x Remote control
• 1x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the Technical data
chapter.
A
B
C
C
D
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Set the device up in an upright and stable position.

5 EN
Operating manual – local air conditioner PAC 5800 X
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are unrolled completely.
• Keep air inlets and outlets as well as the exhaust air hose
connection free.
• Make sure that no curtains or other objects interfere with
the air flow.
Prior to initial start-up, insert the batteries in the remote control.
Inserting the air filter
Note
Do not operate the device without an inserted air filter!
Without an air filter the inside of the device will be
heavily contaminated, which could reduce the
dehumidification performance and result in damage to
the device.
• If required, you can insert the supplied activated carbon
filter in the air filter for the air inlet(10).
• Make sure that the air filters are installed before switching
the device on.
Connecting the exhaust air hose
1. Connect the hose adapter and the hose connector to one
end of the exhaust air hose each.
2. Connect the suitable end of the exhaust air hose to the
exhaust air hose connection(9) located at the device.

EN 6
Operating manual – local air conditioner PAC 5800 X
Discharging exhaust air
• The exhaust air coming from the device contains waste
heat from the room to be cooled. For this reason it is
recommended to discharge the exhaust air to the outside.
• The end of the exhaust air hose can be fed through the
open window. If required, secure the open window with
the corresponding means, so that the end of the exhaust
air hose cannot shift.
• The end of the exhaust air hose can also be hooked into a
tilted window.
For this purpose, we recommend using a window seal
(optional).
• Install the exhaust air hose inclined with the air direction.
Example with exhaust air hose:
For installing the exhaust air hose please observe the following:
≥30 cm
≤150 cm
• Avoid kinks and bends in the exhaust air hose, as they
would lead to an accumulation of emitted humid air
causing the device to overheat and shut down.
• The dimensions of the exhaust air hose were especially
made to fit the device. Do not replace or extend the hose,
for it could cause a malfunction.

7 EN
Operating manual – local air conditioner PAC 5800 X
Opening the ventilation flaps
• Prior to switching the device on, open the horizontal
ventilation flaps at the air outlet(11). Adjust the horizontal
and vertical ventilation flaps to the desired position.
Connecting the power cable
• Insert the mains plug into a properly secured mains
socket.
Operation
• Avoid open doors and windows.
Operating elements
14 15 16 17 18 19 20 21
22
23
24
25
26
12
No. Designation Meaning
12 Segment display Display of current room
temperature
Indication of the target
temperature
Indication of the number of hours
during timer programming
Indication of the error code, see
chapter Errors and faults
14 Timer LED Illuminated when the timer
function is active
No. Designation Meaning
15 Timer button Automatic switch-on timer
function in increments of 1hour
(1h to 24h)
Automatic switch-off timer
function in increments of 1hour
(1h to 24h)
16 Speed button Setting the fan speed
17 Fan speed LEDs Ilow fan speed
II medium fan speed
III high fan speed
18 Operating mode
LEDs
automatic operation
cooling
dehumidification
ventilation
19 Mode button Selecting the operating mode:
automatic operation
cooling
dehumidification
ventilation
20 On / Off button Switching the device on and off
21 Water filling level
LED
Empty condensation tray
indication
22 Compressor
operation LED
Indication of compressor operation
in cooling mode
23 Down button
(decrease value) Setting the target temperature for
cooling between 18°C and 32°C
24 Up button
(increase value)
25 Sleep button Switching night mode on and off
26 Sleep LED Night mode indication
Switching the device on
1. Allow the device to rest for a time.
2. Once you have completely installed the device as
described in the Start-up chapter, you can switch it on.
3. Press the On/ Off button(20).
ðThe device will be switched on in automatic operation.
ðThe current room temperature is indicated on the
segment display(12).
4. Select the desired operating mode.
The device switches off automatically when the condensation
tank is full. The water filling level LED(21) flashes and an
acoustic signal is emitted.

EN 8
Operating manual – local air conditioner PAC 5800 X
Setting the operating mode
The device has the following operating modes:
• automatic operation
• cooling
• dehumidification
• ventilation
Automatic operation
In automatic operation mode the cooling or ventilation process
will be regulated depending on the ambient temperature and the
preset target temperature of 24°C.
1. Press the Mode button(19) until the LED for automatic
operation(18) is illuminated.
ðIf the ambient is >25°C, the device will automatically
operate in cooling mode. The LEDs for automatic
operation(18), cooling(18), fan speed(17) and possibly
compressor operation(22) are illuminated. When
combining automatic and cooling operation, the fan
speed is regulated automatically.
ðAt an ambient temperature of ≤25°C the device
automatically switches over to fan operation. The LEDs
for automatic operation(18), ventilation(18) and fan
speed(17) are illuminated. When combining automatic
operation and ventilation, the desired fan speed may be
set using the Speed button(16).
Cooling
In cooling mode the room will be cooled down to a desired
target temperature.
Cooling commences when the ambient temperature equals the
set temperature + 3 °C.
Default settings in cooling mode:
1. Press the Mode button(19) until the LED for cooling(18)
lights up.
2. Press the buttons Down (decrease value; 23) or
Up (increase value; 24) to adjust the desired room
temperature.
ðThe target temperature flashes for approx. 5s. Then the
current room temperature will be displayed.
ðThe compressor possibly switches on and the LED for
compressor operation(22) lights up.
Dehumidification
Info
Remove the exhaust air hose during dehumidification,
otherwise the performance will be insufficient.
In dehumidification mode the humidity level in the room is
reduced.
The temperature cannot be adjusted and the fan runs at the
lowest speed level.
1. Press the Mode button(19) until the LED for
dehumidification(18) lights up.
ðThe compressor switches on and the LED for
compressor operation(22) lights up.
Info
If the device is operated in a very humid environment,
the accumulating condensate must be discharged at
regular intervals (see chapter Condensate discharge).
If you use the device for an extended period of time or you don't
want to empty the tank all the time, you can connect a
condensation drain hose to the hose connection.
1. Switch the device off.
2. Hold onto the mains plug while pulling the power cable out
of the mains socket.
3. Carefully transport or wheel the device to a suitable
location for discharging the condensate (e.g. a drain) or
position a suitable collection container under the
condensate outlet.
4. Unscrew the sealing cap from the hose connector(7).
5. Remove the rubber stopper from the hose connection.
6. Keep sealing cap and rubber stopper for later use.
7. Connect the condensation drain hose included in the scope
of delivery to the hose connector. Check the condensation
drain hose for tight fit.
8. Lead the condensation drain hose to a drain or sufficiently
dimensioned collection container. To ensure that the
condensate can run off, the condensation drain hose must
not be kinked, nor should it have to overcome an uphill
incline towards the drain.
9. Insert the mains plug into a properly secured mains
socket.
10. Switch the device on.

9 EN
Operating manual – local air conditioner PAC 5800 X
Ventilation
Info
Remove the exhaust air hose during ventilation.
In ventilation mode the room air is circulated, it will neither be
cooled nor dehumidified.
1. Press the Mode button(19) until the LED for
ventilation(18) lights up.
2. Press the Speed button(16) to set the desired fan speed.
ðThe LED for the selected fan speed(17) will be
illuminated.
Setting the timer
The timer has two modes of operation:
• automatic switch-on upon expiry of a preset number of
hours.
• automatic switch-off upon expiry of a preset number of
hours.
The function can be set in all operating modes and also during
stand-by.
The number of hours can be between 1 and 24 and can be
adjusted in increments of 1h.
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Automatic switch-on
üThe device is switched off.
1. Press the Timer button(15) until the desired number of
hours is displayed.
2. Wait for approx. 5seconds in order to save the setting.
ðThe Timer LED(14) is illuminated.
ðThe timer setting equals the desired number of hours.
ðThe device starts in automatic operation mode after the set
time has passed.
Notes regarding automatic switch-on:
• If the device is disconnected from the power supply, all
settings for automatic switch-on are deleted.
• Manually switching the device on disables the automatic
switch-on function.
• If you select 0hours, the timer will be off.
Automatic switch-off
üThe device is switched on.
1. Press the Timer button(15) until the desired number of
hours is displayed.
ðThe number of hours flashes on the display.
2. Wait for approx. 5seconds in order to save the setting.
ðThe display changes back to the normal indication.
ðThe Timer LED(14) is illuminated.
ðThe timer setting equals the desired number of hours.
ðThe device switches off after the set period of time.
Notes regarding automatic switch-off:
• Pressing the On/ Off button(20) deactivates the automatic
switch-off function.
Night mode
Night mode can only be activated in cooling mode. Night mode
comes with the following settings:
• After one hour the preset temperature is increased by 1°C.
After 2hours the preset temperature will again be
increased by 1°C. Then the temperature is kept constant.
• The fan speed is automatically lowered to the the min.
level and cannot be changed manually.
• After 12hours of operation in night mode the device
switches off automatically.
To deactivate night mode, please proceed as follows:
1. Select cooling mode.
2. Press the Sleep button(25).
ðThe LEDs Sleep(26) and cooling(18) light up.
ðThe fan speed is automatically adjusted to the lowest
level.
3. In order to switch the night mode off, press the Sleep
button(25) once again.
ðThe Sleep LED(26) goes out.
ðFan speed and temperature will return to the level that
was set before night mode was activated.

EN 10
Operating manual – local air conditioner PAC 5800 X
Energy saving
The device comes with an energy efficiency boosting function.
The energy efficiency can be enhanced by filling water into the
water tank(4) of the device. The water is used to additionally
cool the condenser and to reduce the device's power
consumption.
üThe device is switched on.
üThe LED for compressor operation(22) has been illuminated
for at least one hour.
1. Remove the water tank(4).
2. Turn the sealing cap counter-clockwise to unscrew it from
the water tank(4), and fill up to max. 3l of water into the
tank. Afterwards screw the sealing cap back onto the
water tank(4) by turning the cap clockwise.
3. Refit the water-filled tank(4) into the device.
Note:
The water filling level LED(21) will flash if you fill too much
water into the water tank(4). If so, the condensation tray should
be gradually emptied until the LED goes out again (see
Condensate discharge in the Maintenance chapter).
It is not possible to implement the energy-saving measure with
a simultaneously connected condensation drain hose, for the
water will immediately be drained from the tank.

11 EN
Operating manual – local air conditioner PAC 5800 X
Remote control
All settings of the device can also be made using the remote
control included in the scope of delivery.
ON/OFF
MODE
SPEED UP
TIMER
SLEEP
DOWN
27
28
20
24
23
19
25
15
16
No. Designation Meaning
15 Timer button Automatic switch-on timer
function in increments of 1hour
(1h to 24h)
Automatic switch-off timer
function in increments of 1hour
(1h to 24h)
16 Speed button Setting the fan speed
19 Mode button Selecting the operating mode:
automatic operation
cooling
dehumidification
ventilation
20 On / Off button Switching the device on and off
23 Down button
(decrease value) Setting the target temperature for
cooling between 18°C and 32°C
24 Up button
(increase value)
25 Sleep button Switching night mode on and off
27 Remote control
transmitter/receiver
For infrared transmission to the
device
28 Display Display of current room
temperature
Display of target temperature
while setting it
Display of the selected operating
mode
: automatic operation
: cooling
: dehumidification
: ventilation
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Empty the condensation tray if necessary.
• Empty the water tank, if need be.
• If necessary, remove the condensation drain hose and any
residual fluid from it.
• Clean the device according to the Maintenance chapter.
• Store the device according to the Storage chapter.

EN 12
Operating manual – local air conditioner PAC 5800 X
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
• Check the power connection.
• Check the power cable and mains plug for damages.
• Check the on-site fusing.
• Observe the operating temperature according to the
Technical data chapter.
• The condensation tray may be full. Empty the condensation
tray if necessary. The water filling level LED(21) must not
flash.
• Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device works with reduced or no cooling capacity:
• Check whether cooling mode is selected.
• Check the proper fit of the exhaust air hose. In case of
kinks, bends or blockage in the hose, exhaust air cannot
be discharged. Clear the way for the exhaust air.
• Check the position of the ventilation flaps. They should be
opened to the maximum.
• Check the air filter(s) for dirt. If necessary, clean or replace
the air filter(s).
• Check the minimum distance to walls or other objects.
Position the device a little more in the room's centre if
required.
• Check whether any windows and/or doors of the room are
open. If so, close them. The window for the exhaust air
hose has to remain open nonetheless.
• Check the temperature setting at the device. Reduce the
set temperature if it is higher than the room temperature.
The device is loud or vibrates:
• Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
• Check the device for leaks.
The compressor does not start:
• Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10minutes before
reconnecting it.
• Check whether the ambient temperature corresponds to
the target temperature +3°C (in cooling mode) or to
25°C (preset target temperature +1°C in automatic
operation mode). The compressor will not switch on unless
the target temperature is reached.
• The compressor may start up with a delay of 3min, as it is
provided with an internal protection against direct restart.
The device gets very warm, is loud or loses power:
• Check the air inlets and air filters for dirt. Remove external
dirt.
• From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and
air-conditioning or by Trotec.
The device does not respond to the infrared remote control:
• Check whether the distance between remote control and
device is too large and reduce it if necessary.
• Make sure there are no obstacles, such as furniture or
walls, between the device and the remote control. Ensure
visual contact between device and remote control.
• Check the charging status of the batteries and change
them if required.
• If the batteries have only just been changed, check them
for correct polarity and change them if required.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
Error codes
The following error messages can be displayed on the segment
display(12):
Error code Cause Remedy
E1 Error at the room
temperature sensor
Disconnect the device
briefly from the mains.
Should the error still be
displayed after the restart,
please contact the
customer service.

13 EN
Operating manual – local air conditioner PAC 5800 X
Maintenance Maintenance intervals
Maintenance and care interval before every
start-up
as needed at least every
2 weeks
at least every
4 weeks
at least every
6 months
at least
annually
Check air inlets and outlets for dirt and
foreign objects and clean if necessary
X X
Clean the exterior X X
Visually check the inside of the device
for dirt
X X
Check the air filter for dirt and foreign
objects and clean or replace if
necessary
X X
Replace the air filter X
Check for damage X
Check the attachment screws X X
Test run X
Empty the condensation tray and drain
hose
X
Maintenance and care log
Device type: ............................................. Device number: ....................................
Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Check air inlets and outlets for dirt and
foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device
for dirt
Check the air filter for dirt and foreign
objects and clean or replace if
necessary
Replace the air filter
Check for damage
Check the attachment screws
Test run
Remarks:
Empty the condensation tray and drain
hose
1. Date: ................................
Signature: ............................
2. Date: ................................
Signature: ............................
3. Date: ................................
Signature: ............................
4. Date: ................................
Signature: ............................
5. Date: ................................
Signature: ............................
6. Date: ................................
Signature: ............................
7. Date: ................................
Signature: ............................
8. Date: ................................
Signature: ............................
9. Date: ................................
Signature: ............................
10. Date: ..............................
Signature: ............................
11. Date: ..............................
Signature: ............................
12. Date: ..............................
Signature: ............................
13. Date: ..............................
Signature: ............................
14. Date: ..............................
Signature: ............................
15. Date: ..............................
Signature: ............................
16. Date: ..............................
Signature: ............................

EN 14
Operating manual – local air conditioner PAC 5800 X
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Visual inspection of the inside of the device for dirt
1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the
device cleaned by a specialist company for cooling and air-
conditioning or by Trotec.
5. Put the air filter back in.
Refrigerant circuit
• The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.
Cleaning the air filter
The air filters have to be cleaned as soon as they are dirty. This
is brought to light e.g. by a reduced capacity (see chapter Errors
and faults).
Warning
Ensure that the air filters are neither worn nor
damaged. The corners and edges of the air filters must
not be deformed or rounded. Before reinserting the air
filters, make sure that they are undamaged and dry!
Note
Before cleaning the air filter with water or a neutral
cleaning agent, remove the activated carbon filter (if
any) from the air filter.
1. Remove the air filters from the device.
2. Clean the filters using a slightly damp, soft, lint-free cloth.
If the filters are heavily contaminated, clean them with
warm water mixed with a neutral cleaning agent.
3. Allow the filters to dry completely. Do not put any wet
filters into the device!

15 EN
Operating manual – local air conditioner PAC 5800 X
4. Reinsert the air filters into the device.
Condensate discharge (manual draining)
In cooling and dehumidification mode condensate is formed,
which is mostly discharged via the exhaust air.
The remaining condensate is collected in a container within the
housing. The condensate ought to be drained regularly.
If too much condensate accumulates, the device switches off
and the water filling level LED(21) flashes.
1. Carefully transport or wheel the device to a suitable
location for discharging the condensate (e.g. a drain) or
position a suitable collection container under the
condensate outlet.
2. Remove sealing cap and rubber stopper from the
condensate outlet.
3. Drain the condensate.
4. Reinsert the rubber stopper in the condensate outlet and
reattach the sealing cap. Ensure the tight fit of the rubber
stopper, for otherwise there might be uncontrolled water
leakage.
ðThe water filling level LED(21) stops flashing as soon as
the condensate has been drained.
Activities required after maintenance
If you want to continue using the device:
• Leave the device to rest for 12to24hours, so the
refrigerant can accumulate within the compressor.
Wait 12to24hours before switching the device back on!
Acting contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
• Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
• Store the device according to the Storage chapter.

EN 16
Operating manual – local air conditioner PAC 5800 X
Technical annex
Technical data
Model PAC 5800 X
Cooling capacity 5.8kW
Dehumidification performance 2.44l/h
Operating temperature 18°C to 32°C
Temperature setting range 18 °C to 32°C
Max. air volume flow 663m3/h
Mains supply 1/N/PE~ 220 V - 240 V /
50 Hz
Nominal current 10.4 A
Power input (cooling operation) 2.1 kW
Sound pressure level 57 dB(A)
Refrigerant R-410A
Amount of refrigerant 980 g
GWP factor 2,088
CO2 equivalent 2.04t
Dimensions
(lengthx widthx height)
427 x 452x 806mm
Minimum distance to walls and
other objects:
top (A):
rear (B):
sides (C):
front (D):
50 cm
50 cm
50 cm
50 cm
Weight 41.5 kg
Disposal
The icon with the crossed-out waste bin on waste
electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.
The device is operated with fluorinated greenhouse gas which
can be dangerous for the environment and contribute to global
warming when emitted to the atmosphere.
Further information is provided on the nameplate.
Dispose of the refrigerant appropriately and according to the
national regulations.
In the European Union, batteries and accumulators must not be
treated as domestic waste, but must be disposed of
professionally in accordance with Directive 2006/66/EC of the
European Parliament and of the Council of 6September 2006
on batteries and accumulators. Please dispose of batteries and
accumulators according to the relevant legal requirements.

Trotec GmbH & Co. KG
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
www.trotec.com
Table of contents
Other Trotec Air Conditioner manuals

Trotec
Trotec PAC 3500 User manual

Trotec
Trotec PAE 51 User manual

Trotec
Trotec PAE 30 User manual

Trotec
Trotec PT 6500 S User manual

Trotec
Trotec PAC 2010 S User manual

Trotec
Trotec PAE 50 User manual

Trotec
Trotec PAE 26 User manual

Trotec
Trotec PAC 2000 S User manual

Trotec
Trotec PAC 2000 S User manual

Trotec
Trotec PAC-W 2600 SH User manual

Trotec
Trotec pac 2000 e User manual

Trotec
Trotec PAC 4700 X User manual

Trotec
Trotec PAE 11 User manual

Trotec
Trotec PAC 2010 X User manual

Trotec
Trotec PAC 3550 PRO User manual

Trotec
Trotec PAC 4600 User manual

Trotec
Trotec PAC 2100 X User manual

Trotec
Trotec pac 2000 e User manual

Trotec
Trotec PAC 2000 X User manual

Trotec
Trotec PAE 22 User manual