TTS Easi-Scope 2 User manual

User Guide

Easi-Scope 2 User Guide
1
Warnings
Please retain these instructions for future reference
Easi-Scope 2 contains a non-replaceable, rechargeable
battery
Do not attempt to remove the battery
In the event of an electro-static discharge, your
Easi-Scope 2 may malfunction. In this case, please
switch it off and then back on again
Warranty is void if the case is opened for any reason
The warranty does not cover any data loss nor any
consequential loss of information
Features
Easi-Scope 2 is a USB Wireless Microscope which uses the
2.4GHz frequency band to transmit digital images of up to 640 x
480 resolution with a range of over 10m. The USB receiver of
your Easi-Scope 2 can pair with up to four (4) Easi-Scope 2s
simultaneously and allow you to switch between the multiple
paired devices.

Easi-Scope 2 User Guide
2
Package Contents
Easi-Scope 2
×1
USB Receiver
×1
Installation CD
×1
User Manual
×1
USB Charging Cable
×1

Easi-Scope 2 User Guide
3
Minimum Requirements
1.8 GHz Intel / AMD Processor;
256 Mbytes of RAM;
USB Version 2.0;
A Compact Disc Drive;
Supported Operating Systems
Windows XP SP3, Windows Vista and Windows 7.
Part and Control Locations
1.
Snap Button
2.
Focusing Dial
3.
Power / Pairing Button
4.
USB Socket
5.
Objective Lens Tube
6.
LED Illumination
7.
Status Indicator
8.
Channel Indicator
9.
Channel Select/Pairing Button

Easi-Scope 2 User Guide
4
Installing Hardware Driver and Application
Plug your USB Receiver into your computer and wait for
the automatic Windows hardware installation to finish.
Insert the Installation CD into your optical drive and the
Easi-Scope 2 Installer should launch automatically. If
this doesn’t start, go to ―My Computer‖, select the CD
drive and double click on setup.exe
When the Easi-Scope 2 InstallShield Wizard appears,
Click Next.
Wait for installation to be completed and then click
―Finish‖ to close the Easi-Scope 2 InstallShield Wizard.
Using your Easi-Scope 2
Charging your Easi-Scope 2
Your Easi-Scope 2 is equipped with a built-in rechargeable
battery which is charged using the mini-USB connector on the
side of your Easi-Scope 2. Fully charge the battery before your
first use.
To Charge the battery, plug-in the supplied USB cable to your
Easi-Scope 2 and to your computer. When charging your Easi-
Scope 2, the Status Indicator on your Easi-Scope 2 lights up until
the battery is fully charged.

Easi-Scope 2 User Guide
5
If the battery of your Easi-Scope 2 is running low, the Status
Indicator flashes slowly.
Note: It is recommended that you do not partially charge the
battery and that you fully charge the battery every time you
charge it.
Start Up
Start up your computer.
Plug in your Easi-Scope 2 USB Receiver to your
computer.
Switch ON your Easi-Scope 2 by pressing the
Power/Pairing button briefly.

Easi-Scope 2 User Guide
6
Pairing
Once your Easi-Scope 2 has started up, you may need to pair
your Easi-Scope 2 with your USB Receiver if:
You are using your Easi-Scope 2 for the first time or,
Your Easi-Scope 2 has previously been paired with another
USB Receiver.
The pairing procedure is as followed:
Start up your computer, Plug in your USB Receiver,
launch your Easi-Scope 2 application and switch ON
your Easi-Scope 2.
Press and Hold the Power/Pairing Button on your Easi-
Scope 2 for seven (7) seconds until the Status Indicator
flashes#rapidly, which indicated that your Easi-Scope 2
has entered Pairing Mode*.
Press and Hold the Pairing Button on the USB Receiver
for three (3) seconds until the Channel Indicator LED
flashes rapidly, which indicated that your USB Receiver
has entered Pairing Mode*.
Once both devices enter pairing mode, they will initiate
the pairing process. You will shortly be able to see the
image in your Easi-Scope 2 application.

Easi-Scope 2 User Guide
7
* Pairing mode timeout is set to be 15 seconds on your Easi
Scope 2 and your USB Receiver. If pairing is not successful
within this period, your devices will return to their normal state
without being paired. Repeat steps 2 to 4 to pair your devices
again.
# The Status Indicator will not flash if you are charging the battery
of your Easi-Scope 2.
Pairing multiple Easi-Scope 2s
Your Easi-Scope 2 USB Receivers are capable of pairing up to
four (4) Easi-Scope 2s and allow you to switch between the
image sources. To pair multiple Easi-Scope 2s, follow the
procedure below.
Pair the first Easi-Scope 2 using the pairing procedure
described in the previous section.
Once completed, click the Channel Select/Pairing Button
once to switch to the next pairing channel.
The Channel Indicator LED on the USB Receiver will
move to the next channel.
Repeat the pairing procedure to pair a 2nd Easi-Scope 2.
Repeat step 2-3 to pair up to four (4) Easi-Scope 2s.

Easi-Scope 2 User Guide
8
Using the Easi-Scope 2 with Easi-Scope 2 Application
Launching the Application
Launch your Easi-Scope 2
application by double clicking on
the Easi-Scope 2 icon. The
Easi-Scope 2 Application
Window appears as shown.

Easi-Scope 2 User Guide
9
Taking a Photo
To take a photo of the image
you are viewing, press the Snap Button
on your Easi-Scope 2.
A new window will pop up. Before saving your photo,
you may rotate your photo as you wish using the
―Rotate‖menu.
Click ―File‖then select ―Save As‖
Recording a Video
To record a video, click Capture
then select Start Capture.

Easi-Scope 2 User Guide
10
If a destination folder has not
been already set, it will ask you to
provide a destination folder to store your
video file. Select a destination folder as
shown, then select OK.
When the screen (left) appears,
select OK to start your recording.
To stop your recording, Click
Capture then select Stop Capture or
press the Esc key on your keyboard
as shown (left).

Easi-Scope 2 User Guide
11
Advance Settings
Changing Resolution
To change the resolution,
click Options then select Video
Capture Pin.
When the Properties
window appears, you can select the
desired resolution using ―Output
Size‖ selection box as shown (left).

Easi-Scope 2 User Guide
12
Support & Warranty
This product has a one-year warranty for problems found during
normal usage. Mistreating the Easi-Scope 2 or opening the unit
will invalidate this warranty. Any data loss or consequential loss is
not covered by this warranty. The battery is not user replaceable.
All out of warranty repairs will be subject to a replacement fee.
Please visit www.tts-group.co.uk for latest product information.
TTS Group Ltd Freephone: 0800 318686
Park Lane Business Park Freefax: 0800 137525
Kirkby-in-Ashfield
Nottinghamshire, UK
NG17 9GU
N448
WARNING! Not suitable for
children under 36 months due
to small parts –choking hazard.
WARNING: Do not dispose of
this product in household waste.
Hand it over to a collection
point for recycling electronic
appliances.
Product Code: EL00132 - Easi-Scope 2
Easi-Scope 2® is a registered trademark of the TTS Group LTD

Easi-Scope 2 Bedienungsanleitung
1
ACHTUNG! ERSTICKUNGSGEFAHR durch verschluckbare
Kleinteile. Nicht für Kinder unter 3 Jahren geeignet.
Warnhinweise
Bitte bewahren Sie diese Anleitung zum späteren
Nachschlagen auf.
Das Easi-Scope 2 enthält eine nicht austauschbare
aufladbare Batterie.
Nicht versuchen, die Batterie zu entfernen.
Wenn es zu einer elektrostatischen Entladung kommt,
funktioniert Ihr Easi-Scope 2 möglicherweise nicht mehr
richtig. Schalten Sie es in diesem Fall aus und wieder
ein.
Wenn das Gehäuse geöffnet wird, erlischt die Garantie.
Datenverluste und Folgeverluste von Daten sind von der
Garantie nicht gedeckt.

Easi-Scope 2 Bedienungsanleitung
2
Merkmale
Das Easi-Scope 2 ist ein USB-Wireless-Mikroskop, das auf dem
2,4-GHz-Frequenzband Digitalbilder mit einer Auflösung von bis
zu 640 x 480 über Entfernungen bis 10 m überträgt. Der USB-
Empfänger Ihres Easi-Scope 2 kann bis zu vier (4) Easi-Scope 2-
Geräte gleichzeitig koppeln und ermöglicht Ihnen, zwischen den
verbundenen Geräten umzuschalten.
Lieferumfang
Easi-Scope 2
×1
USB-Empfänger
×1
Installations-CD
×1
Bedienungsanleitung
×1
USB-Ladekabel
×1

Easi-Scope 2 Bedienungsanleitung
3
Mindestvoraussetzungen
Intel- oder AMD-Prozessor mit 1,8 GHz
256 MB RAM
USB Version 2.0
CD-Laufwerk
Unterstützte Betriebssysteme
Windows XP SP3, Windows Vista und Windows 7

Easi-Scope 2 Bedienungsanleitung
4
Bauteile und Bedienelemente
1.
Schnappschuss-Taste
2.
Fokussierrad
3.
Einschalt-/Pairing-Taste
4.
USB-Anschluss
5.
Optikgehäuse
6.
LED-Beleuchtung
7.
Statusanzeige
8.
Kanalanzeige
9.
Kanalauswahl-/Pairing-Taste

Easi-Scope 2 Bedienungsanleitung
5
Installieren des Hardware-Treibers und der Anwendung
Schließen Sie Ihren USB-Empfänger an einen Computer
an und warten Sie, bis die automatische
Hardwareinstallation in Windows abgeschlossen ist.
Legen Sie die Installations-CD in das CD-Laufwerk ein.
Das Easi-Scope 2-Installationsprogramm wird
automatisch gestartet. Wenn die Installation nicht
gestartet wird, wechseln Sie zu „Arbeitsplatz―, wählen
Sie das CD-Laufwerk aus und doppelklicken Sie auf die
Datei setup.exe.
Wenn der Easi-Scope 2 InstallShield-Assistent wie
abgebildet angezeigt wird, klicken Sie auf „Next―
(Weiter).
Warten Sie, bis die Installation abgeschlossen ist, und
klicken Sie dann auf „Finish― (Fertig stellen), um den
Easi-Scope 2 InstallShield-Assistenten zu schließen.

Easi-Scope 2 Bedienungsanleitung
6
Verwendung des Easi-Scope 2
Laden des Easi-Scope 2
Das Easi-Scope 2 ist mit einer eingebauten aufladbaren Batterie
ausgestattet, die über den Mini-USB-Stecker an der Seite des
Easi-Scope 2 aufgeladen wird. Laden Sie die Batterie vollständig,
bevor Sie das Easi-Scope 2 zum ersten Mal verwenden.
Um die Batterie zu laden, schließen Sie das mitgelieferte USB-
Kabel an das Easi-Scope 2 und Ihren Computer an. Während das
Easi-Scope 2 aufgeladen wird, leuchtet die Statusanzeige am
Easi-Scope 2 auf, bis die Batterie vollständig geladen ist.
Wenn die Batterie des Easi-Scope 2 entladen ist, beginnt die
Statusanzeige langsam zu blinken.
Hinweis: Es wird empfohlen, die Batterie immer vollständig zu
laden.

Easi-Scope 2 Bedienungsanleitung
7
Einschalten
Schalten Sie Ihren Computer ein.
Schließen Sie den Easi-Scope 2 USB-Empfänger an
Ihren Computer an.
Schalten Sie das Easi-Scope 2 EIN, indem Sie die
Einschalt-/ Pairing-Taste kurz drücken.
Pairing
Wenn Ihr Easi-Scope 2 eingeschaltet ist, müssen Sie
möglicherweise das Easi-Scope 2 mit dem USB-Empfänger
koppeln (sog. „Pairing―), wenn:
Sie das Easi-Scope 2 zum ersten Mal verwenden oder
Ihr Easi-Scope 2 zuvor mit einem anderen USB-Empfänger
gekoppelt wurde.
So führen Sie das Pairing durch:
Schalten Sie den Computer ein. Schließen Sie den
USB-Empfänger an, starten Sie die Easi-Scope 2-
Anwendung und schalten Sie das Easi-Scope 2 EIN.
Drücken und halten Sie die Einschalt-/Pairing-Taste auf
dem Easi-Scope 2 sieben (7) Sekunden lang gedrückt,
bis die Statusanzeige#schnell blinkt. Dies zeigt an, dass
sich das Easi-Scope 2 im Pairing-Modus* befindet.
Other manuals for Easi-Scope 2
1
Table of contents
Languages:
Other TTS Microscope manuals
Popular Microscope manuals by other brands

Graham Field
Graham Field BR3088F series instruction manual

Spectrum Technologies
Spectrum Technologies IPM Scope CAM Operation manual

Swift
Swift M2000DF Series Use and care

Swift
Swift M10L Series use and care manual

Ken A Vision
Ken A Vision Research Scope T-29041 instruction manual

3B SCIENTIFIC PHYSICS
3B SCIENTIFIC PHYSICS 500 1003278 instruction manual