1. Preface.....................................................................................3
2.Technical Specification............................................................ 4
3. Understand the Instruments......................................................5
3. Calibration............................................................................... 9
4. Warranty Certificate................................................................14

PREFACE
Please check for following Standard accessories/Observation
1) Product is not physically damaged.
2) Operating manual With Warranty certificate
3) Silicon pressure tubes
5) Carrying Bag.
STANDARED ACCESSORIES
Welcome & thanks for purchasing Our PressCAL Model No-TDP-01B, Our high
Accuracy pressure measurement instrument.
Please refer Technical specifications & instructions carefully before using the product.

TECHNICAL SPECIFICATION
Measurement Range : Various models & ranges available ranging from 0- 0.15 PSI & upto 100 PSI
(Bidirection Pressure ranges also available in request).
Measurement Modes : Differential & Gauge pressure modes /Absolute pressure modes( Prior order
basis).
High Accuracy : 0.1% Full scale
Resolution high resolution of 5 digits ( For higher ranges depends upon the pressure range)
Linearity : Maximum 0.05% FS ( Defined as best fit straight line)
User selectable 12 multiple Pressure measurement units : Kpa, pa , hPa,Bar,mBar, Kg/cm2, PSI ,
mmWC, inWC, cmWC, mmHG, cmHG.
Power supply : 2 AA dry batteries , user replaceable
Battery Back up : 2 Hrs Continuous use with back light on
Measurement Media: Clean Dry gas/Air only
Weight; 410 g without carry case
Enclosure Dimensions : 165 mm(L) ,100mm(B) ,35 mm(W)
Pressure push fit Nipples : 2 units
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.

Hi Pressure input (connect tube)
Low pressure Input (connect tube)
Instrument Switch ON /OFF button
Unit selection key (works as shift digit key in program mode)
Up Arrow key / Increment key (works as resetting key for resetting minimum & maximum values)
Zero Key/Enter (Press for 1 second to zero /tare the pressure display) , this key works as “Enter”
command in program mode
Light Key (switch On/Off for display light), keep display light off for better battery life
Battery level indicator
Unit display
Minimum & Maximum pressure display
Silicon protective cover (removable)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
UNDERSTAND YOUR INSTRUMENT
12
3
4
5
7
10
6
11
98

Battery compartment, Remove Silicon protective cover to replace the battery
Batteries: AA size alkaline

SWITCHING THE UNIT ON
Press switch On key , at the start Unit Model number & serial number will be
displayed , then pressure range will be displayed
INSTRUCTIONS
Users/customers are expected not to use the instrument below & above the
pressure range mentioned, this will permanently damage the sensor
Always Connect pressure tubes with leak free joints
Instrument will perform “Autozero” automatically for first time at the start &
a message will be displayed
“Autozero successfully done”
Users can also press zero key manually for 1 second to perform autozero
manually
User can change & select multiple units by pressing unit selection keys
Upper arrow key /Increment key is used to reset the Minimum & Maximum
values of pressure
Display Back light key is used to switch Off/ On back light , it is
recommended to use backlight when only needed to save battery life ,
backlight automatically goes “switch off” after sometime as programmed in
the setting menu

PROGRAM MODE /SETTING MENU
Switch On the instrument & let it perform auto zero automatically & wait till main display starts
To enter into setting menu long press (Zero Key + Light key) together for 3 seconds continuously
The Display shows the following prompt
FOLLOWING MENU OPTIONS ARE DISPLAYED AFTER ENTERING INTO
SETTING/PROGRAM MODE
Enter password 1204 with help of shift (left) key & Up arrow /Increment key, press Zero
/enter Key to enter the password
If no key is pressed for long time, the instrument will come out of program/ setting mode
Press light key continuously to view back screen mode & come out of setting /program mode
Password
0000
Calibration
Unit
Auto off
Battery count
Sr. No.
1.
2.
3.
4.
5.
Press Enter key to start Calibration mode with help of enter key, After the LCD Display shows the
following prompt

CALIBRATION
Step Calibration (Full calibration Mode)
Edit Values (Adjusting Calibration Values)
Sample(Changing sampling rate)
DpPoint (Deactivated)
Resolution ( Increment or decrement )
1.
2.
3.
4.
5.
Step Calibration Mode is full calibration Mode at 10 multiple points( at every 10 % ) covering
complete instrument range to provide high accuracy of 0.1 % FS throughout the operating range
Use this Mode only when you have calibrated external pressure reference source & hi accuracy
pressure display to calibrate this instrument
Connect the External reference pressure source with calibrated display to the instrument &
following procedure.
Enter the 1. Step calibration mode with help of enter key, After the LCD Display shows the
following prompt
STEP CALIBRATION MODE
Cali.>Step
-------------------------------
Pressure at Zero
+000.000
Adc Count
XXXX
Enter the correct Value of the pressure with help of shift left & Up arrow key

After pressure value shown in zero, Press Enter key to move next 10% point, always
remember to press enter key to savethe value of pressure
After pressure value shown in 10%, Press Enter key to move next 20% point,
Cali.>Step
-------------------------------
Pressure at 10%
+000.030
Adc Count
XXXX
Follow same steps at every 10 % till step calibration is complete till SPAN , a message will appear
that calibration is complete
ACTIVATION OF “EDIT VALUES “IN CALIBRATION MODE
Edit Values correction is used to perform small corrections in calibration values, specific to
the calibration points or defined range
After Entering into setting Mode/Calibration
The calibration mode with help of enter key, After the LCD Display shows the following
prompt

Step Calibration
Edit Values
Sample
DpPoint
Resolution
1.
2.
3.
4.
5.
Enter the 2. Edit Values calibration mode with help of enter key, After the LCD Display shows the
following prompt.
Edit Table
-------------------------------
1. Pressure at Zero
2. Pressure at 10%
3. Pressure at 20%
4. Pressure at 30%
5. Pressure at 40%
6. Pressure at 50%
7. Pressure at 60%
8. Pressure at 70%
9. Pressure at 80%
10. Pressure at 90%
11. Pressure at Span
CALIBRATION

After display edit table in display inter Sr no.1 pressure at Zero with help of inter key (Zero key),
Pressure at Zero
-------------------------------
1. Pressure : +000.000
2. Count : 208203
Edit the Pressure Value & ADC count value according to pressure value With help of left arrow (Unit)
and up arrow key, after editing of count value move to edit table with help of exit key (light key).
After Show edit table in display inter Sr no.2 pressure at 10% with help of inter key (Zero key),
Pressure at 10%
-------------------------------
1.Pressure : +000.030
2.Count : 224746
Edit the count value according to pressure value With help of left arrow(Unit) and up arrow key, after
editing of count value move to edit table with help of exit key (light key).

After Show edit table in display inter Sr no.3 pressure at 20% with help of inter key (Zero key),
Repeat the same procedure for other % values
Edit the count value according to pressure value With help of left arrow(Unit) and up arrow key, after
editing of count value move to edit table with help of exit key (light key).
Pressure at Span
-------------------------------
1.Pressure : +000.300
2.Count : 380893

WARRENTY CERTIFICATE
This is certify that, Dry Block Temperature Calibrator having Sr. No.--------------------
Date-------------------- is propery Tested for workmanship. We Certify our Calibrator for
satisfactory performance for the period of one year from the date of supply against any
manufacturing defect.
Signature
Table of contents
Other Tunix Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

ADA INSTRUMENTS
ADA INSTRUMENTS ZHT 125 Electronic operating manual

Kobold
Kobold OMH-15 operating instructions

Konica Minolta
Konica Minolta CM-3600A instruction manual

Halma
Halma PERMA PURE Baldwin Series user manual

Endress+Hauser
Endress+Hauser Liquiline System CA80CR operating instructions

Greyline Instruments
Greyline Instruments TTFM 1.0 user guide