Turnils FA Series User manual

INSTALLATION MANUAL
FA SERIES
FOLDING ARM AWNINGS
INSTALLATION - OPERATION - CLEANING
Terrace awning
Nordic Light FA20


INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
3
FA SERIES
FOLDING ARM AWNING
FABRICATION & INSTALLATION MANUAL
This Manual is only a guide to the measurement, installation and troubleshooting procedures for the FA Series
Folding Arm Awnings which include:
PICCOLO (FA 22)
SIROCCO Classic (FA 42)
SIROCCO Design (FA 44)
SIROCCO Cross-Over (FA 45)
SIROCCO Fabric Beam (FA 46)
SIROCCO Semi-Cassette (FA 48)
VIENTO Semi-Cassette (FA 58)
Hunter Douglas Limited does not warrant the accuracy contained in this manual.
Copyright 2017 Hunter Douglas Limited [ABN 98 009 675 709] ∫ 08/17
® Registered Trade Marks of Hunter Douglas Limited
Dyneema is a registered Trade Mark of DSM IP Assets B.V ∫Somfy is a registered Trade Mark of Somfy SAS.
Turnils is a registered Trade Mark of Hunter Douglas Scandinavia AB.

INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
4
Ensure that the awning is fixed to a sufficiently secure base.
Warning for decayed wood, plaster that has crumbled away or brick and thin panel material.
Check that windows can be opened after mounting the awning.
The motor and any control equipment must be installed by an authorised electrician.
!
5
FA40-series
Vikarmsmarkis • Folding arm awning
1-2016
Exploded view FA42
Folding Arm
73.9016-40
72.3601
Hood Side Cover
71.2607
Hood
74.6840-70
Roller Tube
74.7050-70
72.3304
Square Tube
74.4140-70
66.1035
66.1151
71.2410
66.1022
Hood Bracket
71.2799
72.3106
Front Tube
74.9540-70
71.5601 71.5613
71.2293
71.2413
66.1151
66.1035
73.9001-02
66.1020
66.1100
66.1093
66.1100
71.2413
Arm Holder
73.9005-06
Crank Handle
72.3216
66.1049
71.2292
66.1066
71.2290
Universal Bracket
71.2796
66.1026
66.1106
71.2417
Drive Bushing
72.3302
71.5601
Wall Bracket
71.2792
End Bracket
71.2790
FA40-series
Vikarmsmarkis • Folding arm awning
21
1-2016
Article No. Description Note Stand. pack
Drive bushing ø 85 mm
Polyamide, for roller tube 74.8560 - 70
Drivbussning
Polyamid, för valsrör 74.8560 - 70
* Includes bushing
72.3305.0000 For gear Shaft 33 mm 10
72.3312.0000 For motor Shaft 20 mm 10
Centre support
Aluminium, tufram
Stödlager
Aluminium, tufram
71.4604.0000 5
Centre support with rollers Only with 70 & 78 mm
Aluminium-polyamide Roller Tube
Stödlager med rullar
Aluminium-polyamide
* 66.1094, 66.1030, 66.1155
71.4609.0001 Vit White 5
71.4609.0182 Silver 5
71.4609.0914 Svart Black 5
Bracket 40 x 40 mm
Aluminium, for centre support 71.4604
Konsol
Aluminium, för stödlager 71.4604
* 66.1094, 66.1030, 66.1155
71.2797.0001 Vit White 65 mm 5
71.2797.0182 Silver 65 mm 5
71.2797.0914 Svart Black 65 mm 5
Centre Support
71.4604
FA40 SERIES
7
FA50-series
Vikarmsmarkis • Folding arm awning
Exploded view FA58
71.2771
73.9093-94
71.2762
72.3106
72.3310
71.4658
74.9850-70
74.9950-70
74.4140-70
66.1151
71.2413
66.1035
71.2766
73.9095
73.9016-40
71.4650
66.1151
66.1035
71.2413 66.1020
66.1100
71.2760
Motor
bracket
Motor
71.2765
74.9750-70
74.7050-70
71.2769
1-2017
FA58

INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
5
RANGE OF APPLICATION
FA-Series is a heavy-duty folding arm awning designed for
terraces, bungalows, balconies, kiosks, shops, restaurants etc.
FA-Series with pitch control provides maximum shading comfort.
The projection angle is infinitely adjustable from -5° to -40° just
by rotating the pitch control eyelets with the crank handle.
OPERATION
External operation by gear or motor. Internal operation by
motor. The motor can be completed with automatic controls, for
example remote control or sun and wind sensors.
INSTALLATION
The awning can easily be installed directly onto the wall or under
the eave. Flexible roof brackets available.
FOLDING ARMS
The arm components are manufactured with pressure die casted
aluminium and the arm profiles of extruded aluminium. The
Dyneema®-tape connection over both knee and arm brackets
improve the stability of the awning. Heavy-duty springs provide
an excellent tension of the fabric.
COMPONENTS
The installation brackets, end bracket and centre supports with
brackets are manufactured with extruded aluminium. Gears are
manufactured with pressure die casted zinc and the removable
crank handle in steel. Bushings for roller tube 70, 71, and 78 mm
are manufactured with pressure die casted zinc, bushings for
roller tube 85 mm in polyamide.
End cap for front and square tube are manufactured with
polyethylene, bushing in self lubricating polyamide.
Fasteners are manufactured with stainless steel, zinc plated
steel or steel surface treated with Dacro 500 LC.
SIROCCO Series Awnings can in most versions be provided with
a hood profile of extruded aluminium and with aluminium hood
side covers and hood bracket in extruded aluminium. Joining
piece in stainless steel.
PROFILES
The front tube and hood profile are manufactured with extruded
aluminium.
Roller tube 70, 78 and 85 mm are manufactured with special
zinc plated steel, roller tube 71 mm in extruded aluminium.
Square tube 35x35mm is manufactured with extruded
aluminium.
Square tube 40x40mm is manufactured with special zinc plated
steel.
COLOURS
Powder coated parts have colour code 0001 for white (RAL9010),
0182 for silver and 0914 for black.
Pigmented plastic parts have colour code 0001 for white
(RAL9010), 0182 for silver and 0049 for black. Untreated or
galvanized parts have colour code 0000. Crank handles in
RAL7035 only.
DIMENSIONS (FA 22)
Projection (m): 1, 1.5, 2, 2.5 and 3m
Max width:
Unit: up to 5m width at 3m projection.
Extension: up to 15m width.
DIMENSIONS (FA 42)
Projection (m): 1.6, 2, 2.5, 3, 3.5 and 4m
Max width:
Unit: up to 7m width at 4m projection.
Extension: up to 15m width.
DIMENSIONS (FA 44)
Projection (m): 1.6, 2, 2.5, 3, 3.5 and 4m
Max width:
Unit: up to 7m width at 4m projection.
Extension: up to 15m width.
DIMENSIONS (FA 45)
Projection (m): 1.6, 2, 2.5, 3, 3.5 and 4m
Max width:
Unit: up to 4.6m width.
DIMENSIONS (FA 46)
Projection (m): 1.6, 2, 2.5, 3, 3.5 and 4m
Max width:
Unit: 7m width at 4m projection.
Extension: up to 15m width
DIMENSIONS (FA 48)
Projection (m): 1.6, 2, 2.5, 3 and 3.5m. Max width:
Unit: up to 7m width at 3.5m projection.
No Extension available
DIMENSIONS (FA 58)
Projection (m): 1.6, 2, 2.5, 3, 3.5m and 4m Max width:
Unit: up to 7m width (6m at 4m projection).
Only Motorised
No Pitch Control, No Roller Valance
ROLLER VALANCE
The Roller Valance option cannot be extended. Therefore, it can
be used up to 7m width maximum.
PRODUCT OVERVIEW

INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
6
Place the awning in the brackets with the supporting profiles. Lock the supporting profile using the
bracket screw.
If face-fixed to masonry, there must be at least seven courses of bricks above the mounting position.
The spreader plate is used with support tube awnings to spread the load over three courses of bricks. A minimum of
four bricks below the spreader plate is recommended.
© Nordic Light 1-2015 3
Terrace awning
Nordic Light FA20
Installation - Operation - Cleaning
Roof bracket 5-45°
Combi bracket
Wall brackets
Place the awning in the brackets
with the supporting profiles. Lock
the supporting profile using the
bracket screw.
b
Universal Bracket
Wall Brackets
Roof Brackets 5-45º
Spreader Plate
INSTALLING THE AWNING
Place the awning in front of the installation site and measure out the height for the external brackets.
These must sit as close to the arm's attachment on the supporting tube as
possible. Mark out and drill the holes for these brackets (NOTE! the wave line).
Mount the brackets using the requisite plugs and screws.
Stretch a piece of string between the outer brackets, mark and drill the holes
for the other brackets.
Keep in mind to place the brackets at the correct height so that the awning
has a ground clearance at the front edge of 2.0 - 2.2 metres.
© Nordic Light 1-20152
Terrace awning
Nordic Light FA20
Installation - Operation - Cleaning
• Ensure that the awning is fixed to a sufficiently secure base.
• Warning for decayed wood, plaster that has crumbled away or brick and thin panel material.
• Check that windows can be opened after mounting the awning.
• The motor and any control equipment must be installed by an authorised electrician.
1 Installing the awning
Place the awning in front of the
installation site and measure out
the height for the external brackets.
These must sit as close to the arm's
attachment on the supporting tube
as possible. Mark out and drill the
holes for these brackets (NOTE! the
wave line). Mount the brackets
using the requisite plugs and screws.
Stretch a piece of string between
the outer brackets, mark and drill
the holes for the other brackets.
Keep in mind to place the brackets
at the correct height so that the
awning has a ground clearance at
the front edge of 2.0 - 2.2 metres.
a

INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
7
ROOF BRACKETS
Roof bracket sets may be used to suspend the awning from rafters. Tiles must be pushed back for access.
The rafter bracket is then bolted to the rafter so that the mounting surface sits on the eaves lining. The
awning mounting bracket has a plate that is adjustable to suit the angle of the rafter from 5º - 45º. The
universal bracket can then be installed to the roof bracket.
Alternatively, the fascia bracket can be used to gain even more height and install an awning on the outside of
the gutter. See sketch.(Use with standard wall bracket).
EAVE FA 42- OnlyFA 42- Only
A. Mount the roof brackets to the roof using a bracket
at each outer end of the roof.
The remaining brackets are mounted at a max. 1.5
metre distance from each other and distributed
evenly over the awning roof.
Screw on the nuts loosely so that the roof can be
adjusted when it is in place.
B. Mount the roof to the square tube and tighten the
screws.
Then move the roof bracket downwards so that the
screw ends up on the underside of the square tube.
Now lock the roof bracket to the square tube using
the screw.
Adjust the roof at the side and against the wall, then
tighten the screws.
C. Screw the ends to the roof's screw pockets once the
roof has been mounted.
© Nordic Light 1-2015 5
Terrace awning
Nordic Light FA20
Installation - Operation - Cleaning
3 Installing the roof
Mount the roof brackets to the roof
using a bracket at each outer end
of the roof.
The remaining brackets are mounted
at a max. 1.5 metre distance from
each other and distributed evenly
over the awning roof.
Screw on the nuts loosely so that
the roof can be adjusted when it is
in place.
a
Mount the roof to the square tube
and tighten the screws.
Then move the roof bracket
downwards so that the screw ends
up on the underside of the square
tube.
Now lock the roof bracket to the
square tube using the screw.
Adjust the roof at the side and
against the wall, then tighten the
screws.
b
Screw the ends to the roof's screw
pockets once the roof has been
mounted.
c
© Nordic Light 1-2015 5
Terrace awning
Nordic Light FA20
Installation - Operation - Cleaning
3 Installing the roof
Mount the roof brackets to the roof
using a bracket at each outer end
of the roof.
The remaining brackets are mounted
at a max. 1.5 metre distance from
each other and distributed evenly
over the awning roof.
Screw on the nuts loosely so that
the roof can be adjusted when it is
in place.
a
Mount the roof to the square tube
and tighten the screws.
Then move the roof bracket
downwards so that the screw ends
up on the underside of the square
tube.
Now lock the roof bracket to the
square tube using the screw.
Adjust the roof at the side and
against the wall, then tighten the
screws.
b
Screw the ends to the roof's screw
pockets once the roof has been
mounted.
c

INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
8
A. Mount the roof brackets to the roof
using a bracket at each outer end of
the roof.
The remaining brackets are mounted
at a max. 1.5 metre distance from
each other and distributed evenly over
the awning roof.
Screw on the nuts loosely so that
the roof can be adjusted when it is in
place.
B. Mount the roof to the square tube and
tighten the screws.
Then move the roof bracket
downwards so that the screw ends up
on the underside of the square tube.
Now lock the roof bracket to the
square tube using the screw.
Adjust the roof at the side and against
the wall, then tighten the screws.
C. Screw the ends to the roof's screw
pockets once the roof has been
mounted.
© Nordic Light 1-2015 5
Terrace awning
Nordic Light FA20
Installation - Operation - Cleaning
3 Installing the roof
Mount the roof brackets to the roof
using a bracket at each outer end
of the roof.
The remaining brackets are mounted
at a max. 1.5 metre distance from
each other and distributed evenly
over the awning roof.
Screw on the nuts loosely so that
the roof can be adjusted when it is
in place.
a
Mount the roof to the square tube
and tighten the screws.
Then move the roof bracket
downwards so that the screw ends
up on the underside of the square
tube.
Now lock the roof bracket to the
square tube using the screw.
Adjust the roof at the side and
against the wall, then tighten the
screws.
b
Screw the ends to the roof's screw
pockets once the roof has been
mounted.
c
© Nordic Light 1-2015 5
Terrace awning
Nordic Light FA20
Installation - Operation - Cleaning
3 Installing the roof
Mount the roof brackets to the roof
using a bracket at each outer end
of the roof.
The remaining brackets are mounted
at a max. 1.5 metre distance from
each other and distributed evenly
over the awning roof.
Screw on the nuts loosely so that
the roof can be adjusted when it is
in place.
a
Mount the roof to the square tube
and tighten the screws.
Then move the roof bracket
downwards so that the screw ends
up on the underside of the square
tube.
Now lock the roof bracket to the
square tube using the screw.
Adjust the roof at the side and
against the wall, then tighten the
screws.
b
Screw the ends to the roof's screw
pockets once the roof has been
mounted.
c

INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
9
BOLTS REQUIRED FOR MOUNTING
Standard Wall/Universal Bracket 2 12mm x 75mm coach bolts & flat washers
2 12mm x 75mm dyna-bolts
Rafter Bracket Set - FA 22/FA 42 Only 2 10mm x 75mm Hex bolts (fully threaded),
nuts & spring washers - brick fix
2 10mm x 40mm Hex bolts (fully threaded),
nuts & spring washers - wood fix
Fascia Bracket- FA 22/FA 42 Only 2 10mm x 75mm Hex bolts (fully threaded),
nuts & spring washers
FA 42, FA 44 & FA 46 - INSTALLATION OF CENTRE SUPPORT
The centre supports should be assembled over the sewing joints which are located closest to the
centre of the awning. Adjust the angle of the centre support so that the fabric does not touch its
lower or upper lip.
ALL - FABRIC
Fabric requirement at projection: arm projection + 250mm excluding valance.
FA 48 - POSITION OF FABRIC ONTO ROLLER TUBE
The fabric should be positioned 40 mm from the edge of bushing on the roller side, to come straight
into the cassette.
FA 58 - POSITION OF FABRIC ONTO ROLLER TUBE
The fabric should be positioned 25 mm from the edge of bushing on the roller side, to come straight
into the cassette.
FA 22, FA 42, FA 44, FA 45 & FA 46 - HOOD
The hood brackets should be assembled 600mm from the end bracket. Max distance between hood
brackets 1500mm.
SPECIAL INSTRUCTION FOR AWNING WITH THREE FOLDING ARMS
The folding arm in the middle should not have any spring tension in the connection between the
folding arm and arm bracket. Remove the spring tension in the centre arm at the arm connection at
the square tube. Remove the pin that holds the Dyneema®-tape with a small flat-headed screwdriver.
FA 22
No of installation bracket per width and projection
Width (m) ≤3m ≤4m ≤5m
1.0m 2 2 2
1.5m 2 2 4
2.0m 2 4 4
2.5m 4 4 4
3.0m 4 4 4
FA 42, FA 44, FA 45, FA 46, FA 48 & FA 58
No of installation bracket per width and projection
Width (m) ≤4 ≤5 ≤6 ≤7
1,6 m 2 2 4 6
2,0 m 2 2 4 6
2,5 m 2 4 4 6
3,0 m 4 4 4 6
3,5 m 4 4 5 6
4,0 m 4 5 5 /
The awning width is defined as the total horizontal length of the awning excluding hood.
The arm brackets should be assembled 1/6 of the total width, from the end bracket, when the combination
of projection and width allows.
FABRICATION GUIDELINES
projection
projection

INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
10
MOTORISED AWNINGS
The limit switches should be adjusted to allow the awning to reach its maximum extension with the cover held
taut, and to retract fully without straining the mechanism.
Fix the wind sensor to its bracket in a vertical position and install it in an exposed position, as close as possible
to the awning. When using a wind sensor with several awnings/screens, install the sensor in a place where it
will be exposed to maximum wind effect.
NOTE:
It is possible to connect one (1) single wind sensor to several controllers (please contact us). But you cannot
connect several wind sensors to one (1) single controller.
Fix the sun sensor to its bracket in a vertical position and install it with the sensor facing the sun.
NOTE:
Use coupling device module when connecting several sun sensors to one (1) single controller. Ask for specific
wiring diagram.
The sun control can most conveniently be checked under sunny conditions by alternately exposing the sensor
to the sunlight and shading it. The wind control can be checked by blowing vigorously on the anemometer
paddles.

INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
11
A. The awning's projection angle is adjusted with the stop
screw and the screw located in the arm holder. Crank out/roll
out the awning.
Adjust one arm at a time. Loosen the arm bracket screw (1)
one to two turns.
!Do not loosen the arm bracket screw more than 3
complete turns.
When adjusting, lift the arm so that the stop screw (2) is not
stressed.
(NOTE! There may be a bang when the arm is lifted and the
conical washer loosens.)
Adjust the stop screw (2) so that the arm has the desired
height position.
The recommended minimum inclination is 10 degrees.
- If the stop screw is screwed in then the arm will
be raised.
- If the stop screw is screwed out then the arm
will be lowered.
Tighten the screw (1) in the arm bracket slightly. The other
arms are adjusted in the same way.
A ground clearance of 2.0 - 2.2 metres at the front edge of
the awning is recommended.
Roll in the awning. Tighten the screw (1) thoroughly.
© Nordic Light 1-20154
Terrace awning
Nordic Light FA20
Installation - Operation - Cleaning
2 Adjustment of projection angle
The awning's projection angle is
adjusted with the stop screw and
the screw located in the arm holder.
Crank out/roll out the awning.
Adjust one arm at a time. Loosen
the arm bracket screw (1) one to
two turns.
When adjusting, lift the arm so that
the stop screw (2) is not stressed.
(NOTE! There may be a bang when
the arm is lifted and the conical
washer loosens.)
Adjust the stop screw (2) so that the
arm has the desired height position.
The recommended minimum
inclination is 10 degrees.
- If the stop screw is screwed in
then the arm will be raised.
- If the stop screw is screwed out
then the arm will be lowered.
Tighten the screw (1) in the arm
bracket slightly. The other arms are
adjusted in the same way.
A ground clearance of 2.0 - 2.2
metres at the front edge of the
awning is recommended.
Roll in the awning.
Tighten the screw (1) thoroughly.
a
Roll out and roll in the awning several times, check that it looks right and functions correctly.
b
1
2
B. Roll out and roll in the awning several times, check that it looks right and functions correctly.
ADJUSTMENT OF PROJECTION ANGLE (FA22, FA40 SERIES)

INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
12
ADJUSTMENT OF PROJECTION ANGLE (FA58 SERIES)
© Hunter Douglas 1-20174
Terrace awning
FA50
Installation - Operation - Cleaning
2 Adjustment of projection angle - Standard
The awning’s projection angle is ad-
justed with the stop screw and the
nuts located in the arm holder.
Crank out/roll out the awning. Ad-
just one arm at a time. Loosen the
arm bracket screws (1) one to two
turns.
When adjusting, lift the arm so that
the stop screw (2) is not stressed.
(NOTE! There may be a bang when
the arm is lifted and the conical
washer loosens.)
Adjust the stop screw (2) so that the
arm has the desired height position.
The recommended minimum incli-
nation is 10 degrees.
- If the stop screw is screwed in
then the arm will be raised. - If the
stop screw is screwed out then the
arm will be lowered.
Tighten the nuts (1) in the arm
bracket slightly. The other arms are
adjusted in the same way.
A ground clearance of 2.0 - 2.2 met-
res at the front edge of the awning
is recommended.
Roll in the awning.
Tighten the nuts (1) more (min
50Nm)
a
1
2
Roll out and in the awning several
times, check that it looks right and
functions correctly.
b
A. The awning’s projection angle is adjusted with the stop screw and
the nuts located in the arm holder.
Crank out/roll out the awning. Adjust one arm at a time. Loosen
the arm bracket screws (1) one to two turns.
!Do not loosen the arm bracket screw more than 3 complete
turns.
When adjusting, lift the arm so that the stop screw (2) is not
stressed.
(NOTE! There may be a bang when the arm is lifted and the
conical washer loosens.)
Adjust the stop screw (2) so that the arm has the desired height
position.
The recommended minimum inclination is 10 degrees.
- If the stop screw is screwed in then the arm will be raised.
- If the stop screw is screwed out then the arm will be lowered.
Tighten the nuts (1) in the arm bracket slightly. The other arms
are adjusted in the same way.
A ground clearance of 2.0 - 2.2 metres at the front edge of the
awning is recommended.
Roll in the awning.
Tighten the nuts (1) more (min 50Nm)
B. Roll out and in the awning several times, check that it looks right
and functions correctly.
ADJUSTMENT OF FRONT PROFILE (FA58 SERIES)
To receive the correct postion of the front profile, the front profile is adjusted as follows:
Roll out the awning until the fabric slackens. Mark position of bracket to ensure you maintain the bracket
position sidewise.
Unscrew the two bottom nuts on the adjustment bracket, holding the front profile.
NOTE! Do not remove the nuts completely.
Move the front profile up or down until receiving the correct position when rolled in.
Fasten the screws.
© Hunter Douglas 1-2017 5
Terrace awning
FA50
Installation - Operation - Cleaning
To receive the correct postion of the front prole, the front prole is adjusted as fol-
lows:
Roll out the awning until the fabric slackens. Mark position of bracket to ensure you
maintain the bracket position sidewise.
Unscrew the two bottom nuts on the adjustment bracket, holding the front prole.
NOTE! Do not remove the nuts completely.
Move the front prole up or down until receiving the correct position when rolled in.
Fasten the screws.
3 Adjustment of front prole FA58

INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
13
CLEANING:
The frame and the fabric are subjected to dirt and pollution and should be cleaned at least once a
year in order to retain their high finish. This is particularly important in more exposed installations, e.g.
environments near the sea. Use a soft cloth, tepid water and a mild cleaner. Do not use a high-pressure
washer as it can damage the awning fabric and any electrical equipment, etc. For a detailed description of
cleaning the fabric, please refer to its usage instructions.
REMOVAL OF THE AWNING'S VALANCE:
The valance is the most exposed part of the awning. To increase the valance's lifespan it can be stored
indoors during the winter months. First loosen the front profile's left or right end cover. Then loosen the
valance's fabric lock. Move the valance to the side so that it slides out from the front profile. Put back the end
cover and store the valance indoors.
CHANGING THE AWNING FABRIC:
Before changing the awning fabric, it is recommended to contact the company from which the awning
was purchased to arrange an inspection of the frame. This company can provide more information about
changing the fabric and also provide advice in case some other component may need to be replaced in order
for the awning to maintain its finish and function.
WARNING - ALWAYS ALLOW A PROFESSIONAL TO ADJUST THE FOLDING ARMS:
An awning has very powerful springs inside the arm's aluminium profiles. If the arm is loosened without first
being secured, it can cause serious personal injury and in the worst case death. The arms must therefore
always be adjusted by a professional.
WARNING - ALWAYS ALLOW A PROFESSIONAL TO LOOSEN THE AWNING'S END COVER:
The awning's end cover may need to be loosened when changing gears, the motor or the fabric. If the
awning's end cover is loosened without all of the awning's arms being secure, the arms can cause serious
personal injury and in the worst case death. The awning's end covers must therefore always be loosened by a
professional.
WARNING - ROLLING OUT THE AWNING:
When washing windows, painting the facade, or carrying out maintenance or repair of the awning, there are
risks, e.g. the ladder tipping over if the awning is rolled out when the work is being carried out. You should
therefore keep the awning rolled up when work is being carried out near the sun protection. The automatic
mechanisms on motorised awnings must be shut off in order to avoid unintentional operation.
Also make sure that the awning cannot make portable infrared or bottled gas heaters tip over or come into
contact with other objects that could damage the awning or cause other injuries.
OPERATING AND MAINTENANCE INSTRUCTIONS FOR AWNINGS

INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
14
NOTES

INSTALLATION - OPERATION - CLEANING —FA SERIES FOLDING ARM AWNING
15

This manual suits for next models
14
Table of contents
Other Turnils Accessories manuals