manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Turo Light
  6. •
  7. Work Light
  8. •
  9. Turo Light VIV-T8BPSP4/9W/35/F User manual

Turo Light VIV-T8BPSP4/9W/35/F User manual

Installation Guide
Please read this installation manual carefully, it contains
important information and notes regarding the installation and
operation of VIVID T8 LED ByPass Tube (BPSP4).
Non-Shunted Lamp Holder
Order
Code Model
Number
24”
24”
24”
24”
36”
36”
36”
36”
48”
48”
48”
48”
48”
48”
48”
48”
Discription Volts
VIV-T8BPSP4/9W/30/F
VIV-T8BPSP4/9W/35/F
VIV-T8BPSP4/9W/40/F
VIV-T8BPSP4/9W/50/F
VIV-T8BPSP4/12W/30/F
VIV-T8BPSP4/12W/35/F
VIV-T8BPSP4/12W/40/F
VIV-T8BPSP4/12W/50/F
VIV-T8BPSP4/12.5W/30/F
VIV-T8BPSP4/12.5W/35/F
VIV-T8BPSP4/12.5W/40/F
VIV-T8BPSP4/12.5W/50/F
VIV-T8BPSP4/14.5W/30/F
VIV-T8BPSP4/14.5W/35/F
VIV-T8BPSP4/14.5W/40/F
VIV-T8BPSP4/14.5W/50/F
T8 Bypass 2ft 9W G13 30K Frost Shatterproof DLC4.0
T8 Bypass 2ft 9W G13 35K Frost Shatterproof DLC4.0
T8 Bypass 2ft 9W G13 40K Frost Shatterproof DLC4.0
T8 Bypass 2ft 9W G13 50K Frost Shatterproof DLC4.0
T8 Bypass 3ft 12W G13 30K Frost Shatterproof
T8 Bypass 3ft 12W G13 35K Frost Shatterproof
T8 Bypass 3ft 12W G13 40K Frost Shatterproof
T8 Bypass 3ft 12W G13 50K Frost Shatterproof
T8 Bypass 4ft 12.5W G13 30K Frost Shatterproof DLC4.0
T8 Bypass 4ft 12.5W G13 35K Frost Shatterproof DLC4.0
T8 Bypass 4ft 12.5W G13 40K Frost Shatterproof DLC4.0
T8 Bypass 4ft 12.5W G13 50K Frost Shatterproof DLC4.0
T8 Bypass 4ft 14.5W G13 30K Frost Shatterproof DLC4.0
T8 Bypass 4ft 14.5W G13 35K Frost Shatterproof DLC4.0
T8 Bypass 4ft 14.5W G13 40K Frost Shatterproof DLC4.0
T8 Bypass 4ft 14.5W G13 50K Frost Shatterproof DLC4.0
Tube
Size
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
120-277
1762771
1762356
1762853
1762534
1762296
1762311
1762484
1762514
1762746
1762342
1762833
1762527
1763231
1763313
1763432
1763512
Applicable to the following models
VIVID™ T8 LED ByPass Shatterproof 4 Tube (BPSP4)
THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A FLUORESCENT
LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED
BY CSA OR AUTHORITIES HAVING JURISDICTION.
WARNING
•Risk of re or electric shock. LED Retrot Kit installation requires knowledge of luminaires
electrical systems. If not qualied, do not attempt installation. Contact a qualied electrician.
•Risk of re or electric shock. Install this kit only in the luminaires that have the
construction features and dimensions show in the photographs and/or drawings.
•To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or
other sharp objects.
CAUTION
•Disconnect power at the source before installation. Do not simply switch o xture.
•This item is rated at 120-277V. Installer must determine whether they have 120-277V at
the luminaire before installation.
•This device is not intended for use with emergency exits.
•Do not use with luminaire ballast.
•Do not use with dimmers.
•Do not use if product is damaged.
•Use with supplied non-shunted lamp holders only.
•Connect hot wire only to end cap with theTurolight logo driver side. Opposite end cap
requires no wiring.
•To avoid potential re or shock hazard, do not use this retrot kit in luminaires employing
shunted bi-pin lamp holders.
Note: Non-Shunted Lamp Holder Supplied with LED T8 Luminaire. Shunted lamp
holders are found only in uorescent luminaires with Instant-Start ballasts. Instant -start
ballasts can be identied by the words“Instant Start”or“I.S.”marked on the ballast. This
designation may be in the form of a statement pertaining to the ballast itself, or may be
combined with the marking for the lamps with which the ballast is intended to be used.
For more information, contact the Turolight representative.
•“This luminaire has been modified and can no longer operate the originally intended
lamp,”shall be marked on the retrot luminaire where readily visible by the user during
normal maintenance including relamping (sticker supplied).
•Risk of re or electric shock. Do not modify the circuitry or any electrical components of tube.
•Installers should not disconnect existing wires from lampholder terminals to make new
connections at lampholder terminals. Instead installers should cut existing lampholder
leads away from the lampholder and make new electrical connections to lampholder
lead wires by employing applicable connectors.
•Suitable for damp location.
•Suitable for“Type IC”or“Type Non-IC”luminaires. No external weight or mechanical force
on tube or components.
•Beware of electric shock when installing tube.
•Dispose of uorescent lamps and ballst according to local/provincal/federal regulations.
•Contact your localTurolight Distributor if you have any questions about the installation of this lamp.
L~
Driver
N~
Hot Connecting End
L~
Driver
N~
TO ORDER PLEASE CALL 1-877-736-0447 OR EMAIL: SALES@TUROLIGHT.COM
Tel: (416) 736-0447 •Toll Free: 1 (877) 736-0447 •Fax: (416) 736-4890 •Email: [email protected] •Website: www.turolight.com
COMPLIANT
1. Read all WARNING/CAUTIONS before continuing this section.
2. Ensure xture is 120-277V.
3. Disconnect power at the source.
4. Remove lens if applicable, remove cover and uorescent tubes.
5. Cut all wires that connect ballast. Properly discard ballast or cap o wires.
6. Replace lamp holders at power end with supplied non-shunted lamp holders.
7. Connect hot wire from power source into supplied non-shunted Lamp Holder
“Hot In”.
8. Connect neutral wire from power source into supplied non-shunted Lamp
Holder“Neutral In”.
9. If installing multiple lamps, continue reading. Otherwise skip to section 14.
10. Connect separate hot wire into“Hot Out”from primary source lamp holder
and connect that wire into“Hot In”on the adjacent tube.
11. Connect separate neutral wire into“Neutral Out”from primary source lamp
holder and connect that wire into“Neutral In”on the adjacent tube.
12. Continue this process for additional lamps.
13. Do not wire opposite end of lamp holder.
14. Install lamp with the Turolight logo (driver side) into the wired end.
15. Visibly ax“Modication Sticker”and reinstall housing cover and lens if
applicable.
16. Return power back to source and installation is now completed.
Live
DISCONNECTOR
Neutral
The wires pass to lampholder rst, then to pin.
Live
Neutral
The wires pass to lampholder rst, then to pin.
Note:The luminaire shall only mount max. 4 tubes.
Power Source
120/277V
inin
out out
Hot Neutral
Instructions
3 Lamp Conguration
Single Tube Connection
Multiple Tube Connection
TO ORDER PLEASE CALL 1-877-736-0447 OR EMAIL: SALES@TUROLIGHT.COM
Tel: (416) 736-0447 •Toll Free: 1 (877) 736-0447 •Fax: (416) 736-4890 •Email: [email protected] •Website: www.turolight.com
COMPLIANT

This manual suits for next models

15

Popular Work Light manuals by other brands

Pontec PondoSolar 3 operating instructions

Pontec

Pontec PondoSolar 3 operating instructions

ALYCO 199225 instruction manual

ALYCO

ALYCO 199225 instruction manual

Eurolux FS3LED quick start guide

Eurolux

Eurolux FS3LED quick start guide

Philips LivingColors 6917548PU brochure

Philips

Philips LivingColors 6917548PU brochure

Schumacher Electric SL27 Series owner's manual

Schumacher Electric

Schumacher Electric SL27 Series owner's manual

Energetic Lighting MPL1001-LED15K840 installation instructions

Energetic Lighting

Energetic Lighting MPL1001-LED15K840 installation instructions

Renkforce 1342100 operating instructions

Renkforce

Renkforce 1342100 operating instructions

Milwaukee 2735-20 Operator's manual

Milwaukee

Milwaukee 2735-20 Operator's manual

Powerfix Profi Cordless LED work light Operation and safety notes

Powerfix Profi

Powerfix Profi Cordless LED work light Operation and safety notes

ALS RFL251R user manual

ALS

ALS RFL251R user manual

LED2WORK CENALED SPOT AC Flexarm operating instructions

LED2WORK

LED2WORK CENALED SPOT AC Flexarm operating instructions

Vision & Control SLF-100-R625-P-24V Instructions for use

Vision & Control

Vision & Control SLF-100-R625-P-24V Instructions for use

König Electronic KN-LED60 manual

König Electronic

König Electronic KN-LED60 manual

Parkside PAL 2200 A2 manual

Parkside

Parkside PAL 2200 A2 manual

ENKHO 159838.01 Original instructions

ENKHO

ENKHO 159838.01 Original instructions

GlacialTech GL-FL55 Series user manual

GlacialTech

GlacialTech GL-FL55 Series user manual

Pelican 9420 user manual

Pelican

Pelican 9420 user manual

Chicago Electric 96692 Set up and operating instructions

Chicago Electric

Chicago Electric 96692 Set up and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.