SENSE PLUS PURE 2.0 Quick-Start Tip Sheet
This page to be used in conjuction with Tylo Full Manual included
CONNECTION/WIRING DIAGRAM
TAB 208 V 1 Phase 240 V 1 Phase
Model Amperage
Amps
Output
kW
Wire Size
AWG
Amperage
Amps
Output
kW
Wire Size
AWG
Sense - U 7 26 5.3 10 30 7.0 8
Sense - U 8 30 6.3 8 35 8.3 8
Note: Heating elements do not change for voltage changes. The heater output will change
based on the voltage applied to heater. Most North American homes are 240v.
1234
56
78
13
BB4140
120 V~
14 AWG
Max. 6 Amp.
G
5.3-8.3 kW
208/240 V~
x 3
11
10
131415
12
RJ10 4P4C
3 x 14 AWG
RJ10 4P4C
RJ10 4P4C
max 300 feet Pure Control
*
*
&RQQHFW&RQWUROFDEOHÀDW
to jack 8 on circuit board.
Connect NTC Sensor cable
URXQGWRMDFNRQFLUFXLWERDUG
In order for control
to operate light, a
separate 120V supply
must be provided and
connected to heater
Field Connect
three copper
conectors
Sensor
Installation Tip
1.  ,IXVLQJ6HQVRU&RYHU\RXDUHVXSSRVHGWRIHHGWKH
sensor wire through the sensor holder FIRST before running
ZLUHLQVLGHWKHZDOO,IQRWGRQH¿UVWGRRQHRIWKHIROORZLQJ
2.  6HQVRUZLWKPHWDOWDELVXVXDOO\LQVWDOOHGZLWKRXWFRYHU
ZLWKRQHVFUHZWKURXJKWKHVHQVRUWDEGLUHFWO\WRWKH¿QLVKHG
wall.
3.  0RXQWVHQVRUKROGHUFORVHWRVHQVRU6XUIDFHPRXQW
sensor as show in picture. Install cover to hide sensor wire and
any hole made for wire.
4.  DO NOT install cover on top of sensor after installation.
,WFDQDႇHFWKHDWVHQVLWLYLW\DQGFDXVHKHDWHUKLJKOLPLWWRWULS

 

Figure 19: Wiring diagram
1. 17&6HQVRU6HQVH3XUHMDFN
2. ([WHUQDO6ZLWFK2SWLRQDOMDFN
3. 'RRUMXPSHUSUHLQVWDOOHGMDFN
4. N/A
5. N/A
6. N/A
7. N/A
8. 3XUH&RQWUROMDFN
9. N/A
10. Heater
11. Terminal for connection of electrical cable
12. 3XUH&RQWUROMDFN
13. 6HQVRU6HQVH3XUHMDFN
14. Light/terminal for connection of light
15. Door Switch is not required for N. America
16. ([WHUQDO2Q2ႇ6ZLWFKRSWLRQ
Sensor cable can also
be connected to 4 Control cable can also be
connected to 5,6 or 7
Ensure the three U-
shaped copper connectors
installed as shown.



D
O
N
OT
install cover on top of sensor after installation.

p
,WFDQDႇHFWKHDWVHQVLWLYLW
\
DQGFDXVHKHDWHUKL
J
KOLPLWWRWULS
Temperature Sensor Location
Sensor location is very specific and very important for proper function of the sauna heater.
Sensor must be 3” to the front or open side of heater (not in corner), 1” down from ceiling.
Temperature Sensor Installation
SAUNA VENTILATION
1. Using Sensor Cover: To hide cable inside wall cavity, you must first feed the sensor wire through the sensor
holder, then run wire inside the wall, down to area where heater is to be installed.
2. Sensor tip mounts to top of sensor, 1” maximum down from ceiling. Place cover over holder, making sure not to
cover sensor itself.
3. Do NOT mount sensor holder on top of sensor after the fact. (This can affect sensor reading and affect sauna
operation).
4. Many choose to install bare sensor without holder and cover. Arguably, this is optimal installation as sensor is
fully exposed to air temp, not metal (cover) and more accurately reflects air temperature.
Indoor Sauna: Position the air inlet and outlet vents as far away from one another as possible (diagonally opposite).
The outlet vent should be located high on a wall (A), and should be about 19” sq. should be directed back into house – it
should not be discharged directly to the outside.
If outlet wall is inaccessible, install outlet vent in far corner of ceiling. Duct over drop ceiling to area in front of sauna (B).
Outdoor Saunas: Outdoors generally have easy access. Some choose to hold off on vents initially and add later if it
appears to be necessary.)
Do not install inlet and outlet vents on same wall. Bad ventilation can be worse than no ventilation.
PURE 2.0 & ELITE Wi-Fi CONTROL INSTALLATION INSTRUCTIONS
The control panel can be installed inside or outside the sauna room. If the control is installed
inside the room, install no higher than 3’ (90 cm) above the floor. No closer than 12” (30 cm) to
heater.
Before applying the control to the wall, connect it to the heater and electrically test everything first.
INSTALLATION WITHOUT BRACKET
Cut a 1-3/16” (3 cm) hole through the wall big enough for the control panel connector. Clean the
surface where the control will be applied to remove all dust. Attach the double-sided adhesive to
the control panel. Remove the protective backing from the adhesive and press the control panel
firmly to the wall. Silicone sealant can be applied as an extra seal.
INSTALLATION WITH BRACKET
Use the mounting bracket as a template to mark screws holes on the wall. Cut a 1-3/16” (3 cm) hole
through the wall big enough for the control panel connector. (If control cable to be surface
mounted, connector can be fitted in back of mounting bracket.). Use adhesive to mount the control
to the bracket.
See Control box for instructions on howto operate control.
If heater high limit trips, try sauna without rocks.
Assuming it does not trip w/o rocks, try the following.
After itcools, re-install rocks. Pack flatter and smaller rocks tighter in behind back element and in front of
front elements. In middle, stack larger rocks, more loosely.
Use smaller at bottom. Do not press in or bend elements
Annually
Check stone compartment.
Remove all stones. Remove all small stones, gravel and lime-scale from rock compartment.
Replace damaged stones with new ones as required.
First Use:
Turn onheater for one hour to “burn off” any new paint or element oils. The water reservoir does not need to
be operating.
There may be a little smoke initially. This is normal.
Very Important:
Clean rocks before use to remove dust.
Sauna rocks may only be placed in center (deep) rock
compartment (1). Never place stones on top of the
side air chambers (2). This will obstruct air circulation,
causing the unit to overheat and the cut-out switch to
activate.

This manual suits for next models

1

Other Tylo Plumbing Product manuals

Tylo HARMONY User manual

Tylo

Tylo HARMONY User manual

Tylo Prime+ 1811 User manual

Tylo

Tylo Prime+ 1811 User manual

Tylo SAUNA REFLECTION WIDE GF User manual

Tylo

Tylo SAUNA REFLECTION WIDE GF User manual

Tylo T825H User manual

Tylo

Tylo T825H User manual

Tylo Sauna i1915 Corner User manual

Tylo

Tylo Sauna i1915 Corner User manual

Tylo Prime+ 1515/C User manual

Tylo

Tylo Prime+ 1515/C User manual

Tylo 1212 User manual

Tylo

Tylo 1212 User manual

Tylo T810H User manual

Tylo

Tylo T810H User manual

Tylo Space Vision 200 User manual

Tylo

Tylo Space Vision 200 User manual

Tylo Evolve Tradition User manual

Tylo

Tylo Evolve Tradition User manual

Tylo Prime 910 User manual

Tylo

Tylo Prime 910 User manual

Tylo Alu Line 190 User manual

Tylo

Tylo Alu Line 190 User manual

Tylo Tylosand T-825 Operation manual

Tylo

Tylo Tylosand T-825 Operation manual

Tylo ix210 Instruction manual

Tylo

Tylo ix210 Instruction manual

Tylo Tylosand T-820 Operation manual

Tylo

Tylo Tylosand T-820 Operation manual

Tylo Sauna i1115 Corner User manual

Tylo

Tylo Sauna i1115 Corner User manual

Tylo Tylosand T-810 Operation manual

Tylo

Tylo Tylosand T-810 Operation manual

Tylo 2900 2665 User manual

Tylo

Tylo 2900 2665 User manual

Tylo Sauna i1915 Corner User manual

Tylo

Tylo Sauna i1915 Corner User manual

Tylo Space Vision 250 User manual

Tylo

Tylo Space Vision 250 User manual

Tylo Alu Line 150 User manual

Tylo

Tylo Alu Line 150 User manual

Tylo T870H User manual

Tylo

Tylo T870H User manual

Tylo Sauna i1313 User manual

Tylo

Tylo Sauna i1313 User manual

Tylo Prime+ 1814 User manual

Tylo

Tylo Prime+ 1814 User manual

Popular Plumbing Product manuals by other brands

Gessi iSpa 41001 Bath Mixing Program

Gessi

Gessi iSpa 41001 Bath Mixing Program

Villeroy & Boch O.NOVO 416250 installation instructions

Villeroy & Boch

Villeroy & Boch O.NOVO 416250 installation instructions

Signature Hardware VILAMONTE 948686 Installation

Signature Hardware

Signature Hardware VILAMONTE 948686 Installation

BELLOSTA mose Installation instruction

BELLOSTA

BELLOSTA mose Installation instruction

enware aquablend 2000 Installation instruction

enware

enware aquablend 2000 Installation instruction

American Standard Cadet 3 Elongated Toilet 2455 installation instructions

American Standard

American Standard Cadet 3 Elongated Toilet 2455 installation instructions

Olympia K-5040 Installation and Maintenance

Olympia

Olympia K-5040 Installation and Maintenance

LIVARNO home 402407-2204 Installation & operating instructions

LIVARNO home

LIVARNO home 402407-2204 Installation & operating instructions

Blanco Pinnacle 441002 Specifications

Blanco

Blanco Pinnacle 441002 Specifications

Linie BARO installation guide

Linie

Linie BARO installation guide

Signature Hardware COOPER 940967 quick start guide

Signature Hardware

Signature Hardware COOPER 940967 quick start guide

Moen Genta LX 6702BN quick start guide

Moen

Moen Genta LX 6702BN quick start guide

Porcelanosa Noken Project 100212020 N199999054 manual

Porcelanosa

Porcelanosa Noken Project 100212020 N199999054 manual

Elkay ELUH2317 Series installation instructions

Elkay

Elkay ELUH2317 Series installation instructions

Hans Grohe M415-H160 Series Instructions for use/assembly instructions

Hans Grohe

Hans Grohe M415-H160 Series Instructions for use/assembly instructions

Tres CUADRO 250 1.34.140 Technical Characteristics

Tres

Tres CUADRO 250 1.34.140 Technical Characteristics

ShowHouse Felicity TS546 Replacement parts

ShowHouse

ShowHouse Felicity TS546 Replacement parts

BELLOSTA pascal 1000/K installation instructions

BELLOSTA

BELLOSTA pascal 1000/K installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.