CENTAUR
9
4.3 . MECHANICAL HAZARDS
•Risk of injury due to the falling of display
shelves loaded with product. The shelves must
be completely fixed in the holes intended for
this purpose
•It is possible to clamp the hands from the
side of the loops or handles. When
opening/closing the door, follow the location of
people nearby.
•Danger of falling while
sliding. Remove condensation from
the door. Do not allow puddles to
form around the display case. Immediately
remove the melted water leakage from the condensate bath (the condensate bath is located behind the
display case, in the lower part)
•Danger of breaking the glass . Check the glass elements for the absence of such defects as : scratches,
cracks, breaks. In case of damage, contact the service department immediately. Check if the door is closed.
Watch for free passages when opening glass doors. Do not load the door. It is forbidden to store glass
containers
•Danger of overturning the showcase. Danger of pinching people. Only pick up
transport pallets in a stable, supported position. Correctly attach the legs of the showcase to the
floor. When drilling holes, take into account the characteristics of the floor and the base (floor
heating, electric cables, etc. ). Do not climb on the window or climb into it. After installation, only
specialists are allowed to transport the showcase. (see chapter 7 for detailed installation instructions)
•Danger of getting burned on hot surfaces of pipes and components of the refrigerating
machine. If it is necessary to touch the above components when servicing the showcase, you
must first turn it off and wait for them to cool down.
5. PLACEMENT REQUIREMENTS
The showcase must be installed on a flat, horizontal surface.
Insufficient alignment or an unstable position can lead to deterioration of
the performance of the display case.
IT IS FORBIDDEN! Install the showcase in the places indicated in the
figure on the left:
- near a heat source (batteries, heating and cooking equipment);
- near doors and on drafts caused by opening doors or windows;
- in areas where a strong flow of air is possible (for example, output
channels of climate, ventilation and heating systems);
- under direct sunlight.
The presence of air movement at a speed of more than 0.2 m/s in the installation area of the showcase
deteriorates the operational characteristics of the refrigerating showcase. It is necessary to ensure free
air circulation for the unit compartment in the area where the showcase is installed - a distance of at least 15 cm
from the rear wall of the hood to the wall, to remove excess heat from the non- condenser .