EasyCoder 501/601 – Installation Instructions
1
Note:
Illustrations show an EasyCoder 501.
The principles for fitting this optional
equipment in an EasyCoder 601 are
exactly the same.
Type
Art. No.
Ser. No.
115/230 V 2.6/1.3 A 50–60 Hz
INDUSTRIAL INTERFACE KIT
TheIndustrialInterfaceBoardaddsoneserialcommunicationport
("uart3")andoneconnectorwithfourINandfourOUTportstothe
standard serial communication port ("uart1:").
The IN/OUT ports provide an interface between the printer and
varioustypes ofexternal equipment,such asgates, conveyorbelts,
wrappers etc. The input and output signals can be read or initiated
by means of UBI Fingerprint instructions. Thereby the printer can
beusedtocontrol theexternaldevices–orbecontrolledbythem –
according to the program.
Theprinter'ssoftwaredetectswhenanIndustrialInterfaceBoardis
installed and adds communication and buffer setup options for the
communication port "uart3:".
WhenanIndustrialInterfaceBoard isfitted, thefollowing typesof
interfaces become available:
"uart1:"
Fittedon printer's CPU board.
RS232C Standard. Selected by strap.
RS422 or 20 mA CL Option.Additional circuits required.
"uart3:"
Fittedon Industrial InterfaceBoard.
RS232C
IN/OUT connector
Fittedon Industrial InterfaceBoard.
4input channels The software can read the status of four different
inputsignals.
4output channels Thesoftwarecansetfourdifferentsignalstoeither
openor closed contact and alsoread their status.
The Industrial Interface Kit consists of:
1 Interface board assy.
2ScrewsMRX-Z3×6FZB(notintendedforEasyCoder501/601)
Installation Instructions
Introduction
UBI EasyCoder 501/601
Industrial Interface Kit
Installation Instructions
Edition 1, March 1994
Article No. 1-960343-01
"uart1:"
IN/OUT ports
"uart3:"