UBI EasyCoder 501 SA User manual

EasyCoder 501/601 – Installation Instructions
1
Note:
Illustrations show an EasyCoder 501.
The principles for fitting this optional
equipment in an EasyCoder 601 are
exactly the same.
Type
Art. No.
Ser. No.
115/230 V 2.6/1.3 A 50–60 Hz
INDUSTRIAL INTERFACE KIT
TheIndustrialInterfaceBoardaddsoneserialcommunicationport
("uart3")andoneconnectorwithfourINandfourOUTportstothe
standard serial communication port ("uart1:").
The IN/OUT ports provide an interface between the printer and
varioustypes ofexternal equipment,such asgates, conveyorbelts,
wrappers etc. The input and output signals can be read or initiated
by means of UBI Fingerprint instructions. Thereby the printer can
beusedtocontrol theexternaldevices–orbecontrolledbythem –
according to the program.
Theprinter'ssoftwaredetectswhenanIndustrialInterfaceBoardis
installed and adds communication and buffer setup options for the
communication port "uart3:".
WhenanIndustrialInterfaceBoard isfitted, thefollowing typesof
interfaces become available:
"uart1:"
Fittedon printer's CPU board.
RS232C Standard. Selected by strap.
RS422 or 20 mA CL Option.Additional circuits required.
"uart3:"
Fittedon Industrial InterfaceBoard.
RS232C
IN/OUT connector
Fittedon Industrial InterfaceBoard.
4input channels The software can read the status of four different
inputsignals.
4output channels Thesoftwarecansetfourdifferentsignalstoeither
openor closed contact and alsoread their status.
The Industrial Interface Kit consists of:
1 Interface board assy.
2ScrewsMRX-Z3×6FZB(notintendedforEasyCoder501/601)
Installation Instructions
Introduction
UBI EasyCoder 501/601
Industrial Interface Kit
Installation Instructions
Edition 1, March 1994
Article No. 1-960343-01
"uart1:"
IN/OUT ports
"uart3:"

EasyCoder 501/601 – Installation Instructions
2
The only tool required is a Torx #T10 screwdriver.
❑Turn off the power and remove the power cord.
❑Remove the communication cable from communication port
"uart1:".
❑Open the right hand door.
❑Remove the eight Torx screws that hold the cover over the left
part of the printer (see illustration below).
❑Remove the cover.
Continued!
INDUSTRIAL INTERFACE KIT, cont'd.
Step-by-Step Installation
Instructions
Communication
Port "uart1:"
0
230V
MADE IN SWEDEN
Type
Art. No.
Ser. No.
115/230 V 2.6/1.3 A 50–60 Hz
TA
Power
Switch
Power Cord
Receptacle
F1 F2 F3 F4 F5
Pause
Setup
Feed
Enter
7 8 9
4 5 6
1 2 3
. 0 C
Print
Power Ready Error
EasyCoder 501 E
Screws (4x)
Cover
Screws (4x)

EasyCoder 501/601 – Installation Instructions
3
❑Remove the existing cover plate.
❑Make sure that the CPU board is strapped and equipped for the
desired type of communication on "uart1:" (see the EasyCoder
501 or EasyCoder 601 Technical Description). Once the inter-
face board has been fitted, it will be difficult to access the rear
part of the CPU board.
❑Fit the required straps on the Industrial Interface Board as
described on page 5.
❑Connect the cable from the interface board to connector P-4 at
the bottom rear corner of the CPU board. Be careful so the
interface board and the CPU board do not come in contact with
eachother,whichpossiblymaycausedamageorshort-circuiting.
❑Fit the interface board assembly to the printer's rear plate from
theinsideasillustratedbelowusingthesamescrewsthatheldthe
removed cover plate.
Continued!
INDUSTRIAL INTERFACE KIT, cont'd.
Step-by-Step Installation
Instructions, cont'd.
P2P6P7P8
123123123123
P1
Industrial
Interface Board
Connect to P-4
on CPU Board
Rear Plate
Screw
Screw
Female DB15
I/O Connector
Female DB25
Connector
"uart3:"

EasyCoder 501/601 – Installation Instructions
4
INDUSTRIAL INTERFACE KIT, cont'd.
Continued!
Step-by-Step Installation
Instructions, cont'd. ❑Reassemble the printer in reverse order.
❑Connect the communication cables to their respective connec-
tors. Please refer to page 6 for pinout descriptions.
❑Connect the power cord and turn on the power.
❑Ifyouintendtousethecommunicationport"uart3:"(RS232C),
set up its communication and buffer parameters as described in
the EasyCoder 501 or EasyCoder 601 Technical Description.
Type
Art. No.
Ser. No.
115/230 V 2.6/1.3 A 50–60 Hz
"uart1:"
"uart3:"
IN/OUT
Ports
Industrial Interface
Board Assy.

EasyCoder 501/601 – Installation Instructions
5
INDUSTRIAL INTERFACE KIT, cont'd.
Straps
Communication Port "uart3:"
RS 232C:
There are no straps for controlling the RS 232C interface on
"uart3:".
External +5V:
External +5V ( max. 200 mA) can be made available on pin 16 by
fitting a strap on P-1.
Be careful not to enable this option unintentionally, which may
cause harm to the connected terminal, computer or other device.
In/OUT Connector
In/Out port 201-204:
One relay for each port switches the OUT signal to open or closed
as PORTOUT ON/OFF statements are executed in the program.
Four straps, P-2, P-6, P-7 and P-8, control the relation between
relay and output signal on output ports 201–204 respectively:
PORTOUT stmt Strap between pins OUT signal
PORTOUT(<nexp>) ON 1–2 (upper position) Open
PORTOUT(<nexp>) ON 2–3 (lower position) Closed
PORTOUT(<nexp>) OFF 1–2(upper position) Closed
PORTOUT(<nexp>) OFF 2–3(lower position) Open
P4
P2
P3
P5
P6P7P8
123123123123
P1
"uart3:"
I/O connector
P-6
P-8
P-1
P-2
P-7

EasyCoder 501/601 – Installation Instructions
6
Pin "uart3:" Remarks Pin In/Out connector Remarks
DB25female DB15 female
1 GNDC Cableshield 1 OUT201 Seeexample below
2 TXDB Transmitteddata from printer 2 OUT201
3 RXDB Receiveddata to printer 3 OUT202
4 RTSB RTSfrom printer 4 OUT202
5 CTSB CTSto printer 5 OUT203
6 DRSB DSRto printer 6 OUT203
7 GNDI Signalground 7 OUT204
8 – notused 8 OUT204
9 – notused 9 IN101 See example below
10 – notused 10 IN101
11 – notused 11 IN102
12 – notused 12 IN102
13 – notused 13 IN103
14 – notused 14 IN104
15 – notused 15 IN103/104
16 +5VEXT +5V max 200 mA*
17 – notused
18 – notused
19 – notused
20 DTRB DTRpemanently high
21 – notused
22 – notused
23 – notused
24 – notused
25 – notused
*/.If strapfitted onP-1
INDUSTRIAL INTERFACE KIT, cont'd.
Connector Configuration "uart3:" is a DB25 female connector.
The In/Out connector is a DB15 female connector.
The mounting holes are connected to chassis ground.
OUT signals are controlled by means of
PORTOUT (<nexp>) ON|OFF statements.
IN and OUT signals are read by means of
PORTIN (<nexp>) functions.
Also see UBI Fingerprint Programmer's Manual.
IN1
9
10
P-3
TIL193B R5 R6
C10
Example of an IN portExample of an OUT port
+5V
1
2
P-3
REL1
1
OUT1
P-2
32
POWER: max. 240VA
VOLTAGE: max. 60VAC
CURRENT: max. 4A
VOLTAGE: 10–48V
CURRENT: 3–16mA
Informationinthismanualissubjecttochangewithoutpriornoticeanddoesnotrepresentacommitment
on the part of UBI Printer AB.
© Copyright UBI Printer AB, 1994. All rights reserved. Published in Sweden.
EasyCoder is a trademark of United Barcode Industries (UBI).
Torx is a registered trademark of Camcar Division of Textron Inc.
Other manuals for EasyCoder 501 SA
4
This manual suits for next models
3
Other UBI Printer Accessories manuals