UE 100 Serie User manual

IMP100-06
sure connection. Low pressure and differential pressure units, models
520-535, 540-543, 544-548, are also available with an optional
surface mounting bracket. Should the control be installed where con-
densation is expected, vertical mounting is recommended as a means of
keeping water away from switch terminals.
Never use the enclosure for leverage to hand tighten the pressure con-
nection. Always use a wrench to tighten the pressure connection to the
pipe.To prevent damaging the pressure sensor, use a back-up wrench
to hold the hex nut in place when surface mounting.
On models supplied with an external manual reset button, be sure to
leave sufficient finger space over the reset button for the operator to
reset the control. See Mounting Diagram.
WIRING
DISCONNECT ALL SUPPLY CIRCUITS BEFORE WIRING.
ELECTRICAL RATINGS STATED IN LITERATURE AND ON
NAMEPLATES SHOULD NEVER BE EXCEEDED. OVERLOAD
ON A SWITCH CAN CAUSE FAILURE ON THE FIRST CYCLE.
WIRE UNITS ACCORDING TO NATIONAL AND LOCAL ELECTRICAL
CODES. MAXIMUM RECOMMENDED WIRE SIZE IS 14 AWG.
Remove the two screws retaining the cover and cover gasket. Two
cast-in knockouts for 1/2” conduit are located on the side and
back of enclosure. These can easily be knocked out by placing the
blade of a screwdriver in the groove and tapping sharply with a
hammer. A 1/2” NPT conduit connection is also provided on
the left hand side of the enclosure. The three switch terminals
are clearly labeled “common”, “normally open” and “normally
closed”. For switches supplied with leadwires, the following color
coding applies:
Manual DPDT
Reset (Option 1010)
SPDT SWT1 SWT2
Common Violet Violet Yellow
Normally Open Blue Blue Orange
Normally Closed Black Black Red
GENERAL
BEFORE INSTALLING, CHECK THE SENSOR MODEL SELECTED
FOR COMPATIBILITY TO THE PROCESS MEDIA IN CONTACT WITH
THE SENSOR AND WETTED PARTS.
The H100 and H100K differential pressure switches are activated when
a bellows, diaphragm or piston sensor responds to a pressure change.
This response, at a pre-determined set point, actuates a single snap-
acting switch, converting the pressure signal into an electrical signal.
Control set point may be varied by turning the internal adjustment hex.
(See Adjustment -PART II).
PROOF PRESSURE* LIMITS STATED IN THE LITERATURE AND ON
NAMEPLATES MUST NEVER BE EXCEEDED, EVEN BY SURGES
IN THE SYSTEM. OCCASIONAL OPERATION OF UNIT UP TO
PROOF PRESSURE IS ACCEPTABLE (E.G., START-UP, TESTING).
CONTINUOUS OPERATION SHOULD NOT EXCEED THE DESIGNATED OVER
RANGE PRESSURE.
*Proof Pressure
The maximum pressure to which a pressure sensor may be occasionally
subjected, which causes no permanent damage (e.g., start-up, testing).
The unit may require re-gapping.
Tools Needed
Adjustable Wrench
Screwdriver
Hammer (for alternate wire knockouts)
MOUNTING
INSTALL UNIT WHERE SHOCK, VIBRATION AND TEMPERATURE
FLUCTUATIONS ARE MINIMAL. ORIENT UNIT SO THAT MOIS-
TURE IS PREVENTED FROM ENTERING THE ENCLOSURE. IF
UNIT IS BEING INSTALLED WHERE HEAVY CONDENSATION IS EXPECTED,
VERTICAL MOUNTING (PRESSURE CONNECTION DOWN) IS REQUIRED. DO
NOT MOUNT IN AMBIENT TEMPERATURES EXCEEDING PUBLISHED LIMITS.
Controls may be mounted and operated in any
position. They may be surface mounted via the two mounting ears on
either side of the enclosure, or directly to a rigid pipe by using the pres-
100 Series
Pressure Switch
Types H100, H100K
(Differential Pressure)
IMP100-06
Please read all instructional literature carefully and thoroughly before starting. Refer to the final page for the listing of Recommended
Practices, Liabilities and Warranties.
Part I - Installation
UNITED ELECTRIC
CONTROLS
Installation and Maintenance
Instructions

IMP100-06
Models Flats Approx. Gap
171-174 2-2 1/2 .0085 to .0105”
183-194 1-1 1/2 .004 to .006”
483-494 1-1 1/2 .004 to .006”
358-376 5-6 .020 to .025”
700-706 3 1/2 - 4 .014 to .017”
521-525 2-2 1/2 .0085 to .0105”
531-535 2-2 1/2 .0085 to .0105”
540-548 2-2 1/2 .0085 to .0105”
560-567 1-1 1/2 .004 to .006”
15623 5-6 .020 to .025”
A grounding screw and clamp (cast in symbol) is provided which meets
a 35 lb. pull test. Keep the wire as short as possible to prevent inter-
face with the plunger and the adjustable differential switch wheel, if
applicable.
Tools Needed
5/8” Open End Wrench
SOME MODELS HAVE A TWO-PIECE, ADJUSTABLE
PLUNGER. THIS FEATURE IS CHARACTERIZED BY A 3/16” HEX
HEAD SCREW INSTALLED IN THE 1/4” HEX PLUNGER. THE
LENGTH OF THIS ASSEMBLY IS ADJUSTED AT OUR FACTORY AND IS CRITI-
CAL TO THE FUNCTION OF THE CONTROL.
H100 and H100K
Remove pressure switch cover. Loosen Phillips screw adjustment lock.
Adjust set point by turning 5/8” hex adjustment screw clockwise (in) to
raise set point, or counter clockwise (out) to lower set point. Tension on
adjustment screw can be increased by tightening adjustment lock onto
it. (See diagram 1). Controls include uncalibrated reference scales for
high, low or mid range settings.
Adjustable Differential Models
Model 15623 and control types with option code 1519 incorporate
a snap switch with internal adjustment wheel. Turning this wheel
raises or lowers the pressure rise set point. The fall set point remains
constant. Consult factory for additional information.
Manual Reset Button
Control types with option code 1530 incorporate a snap switch which
when actuated, remains actuated until the pressure drops sufficiently
to allow the reset button (located on top of the control) to be manually
depressed to reset the switch.
Gapping
1) Loosen adjustment lock.
2) Turn 5/8” hex adjustment screw in, to approximately mid range.
This puts a load on the sensor and exposes the plunger flats. Using
a 1/4” wrench on the plunger and a 3/16” wrench on the plunger hex
screw, turn hex screw out from plunger until switch actuates. If switch
is already actuated, turn plunger hex screw in, until switch deactuates.
Turn hex screw in from this point. (See chart 1 for Flats and approxi-
mate Gap.)
3) Check set point according to Part II Adjustments.
4) Connect wires and replace cover securely.
Part II - Adjustments
Diagram 1
Chart 1

IMP100-06
IMP100-06
Models 171-174,
471-474
Models 183-186,
483-486
Models 188-194.
488-494
Dimensions
Models 218-376,
610-706, 15623
Models 520-525 Models 530-535
Dimension A
Model Inches mm NPT
171-174 7.50 190,5 1/2”
183-186 7.56 192,0 1/2”
188,189 6.62 168,1 1/2”
190-194 6.63 168,4 1/2”
218-274 6.56 166,6 1/4”
358-376 7.03 178,6 1/4”
483-486 7.56 192,0 1/2”
488,489 6.62 168,1 1/2”
490-494 6.63 168,4 1/2”
520-525 8.44 214,4 1/2”
530-535 8.00 203,2 1/2”
540-548 8.34 211,8 1/8”
560-564 6.62 168,1 2” Sanitary fitting
565-567 6.62 168,1 1 1/2” Sanitary fitting
610-616 7.00 177,8 1/4”
680 6.97 177,0 1/4”
701-706 6.57 166,9 1/4”
15623 6.57 166,9 1/4”

IMP100-06
IMP100-06
RECOMMENDED PRACTICES AND WARNINGS
United Electric Controls Company recommends careful consideration of the following factors when
specifying and installing UE pressure and temperature units. Before installing a unit, the Installation and
Maintenance instructions provided with unit must be read and understood.
• To avoid damaging unit, proof pressure and maximum temperature limits stated in literature and on
nameplates must never be exceeded, even by surges in the system. Operation of the unit up to
maximum temperature is acceptable on a limited basis (i.e., start-up, testing) but continuous operation
must be restricted to the designated adjustable range. Excessive cycling at maximum temperature limits
could reduce sensor life.
• A back-up unit is necessary for applications where damage to a primary unit could endanger life,
limb or property. A high or low limit switch is necessary for applications where a dangerous runaway
condition could result.
• The adjustable range must be selected so that incorrect, inadvertent or malicious setting at any
range point cannot result in an unsafe system condition.
• Install unit where shock, vibration and ambient temperature fluctuations will not damage unit or affect
operation. Orient unit so that moisture does not enter the enclosure via the electrical connection.
When appropriate, this entry point should be sealed to prevent moisture entry.
• Unit must not be altered or modified after shipment. Consult UE if modification is necessary.
• Monitor operation to observe warning signs of possible damage to unit, such as drift in set point or
faulty display. Check unit immediately.
• Preventative maintenance and periodic testing is necessary for critical applications where damage
could endanger property or personnel.
• For all applications, a factory set unit should be tested before use.
• Electrical ratings stated in literature and on nameplate must not be exceeded. Overload on a switch
can cause damage, even on the first cycle. Wire unit according to local and national electrical codes,
using wire size recommended in installation sheet.
• Do not mount unit in ambient temp. exceeding published limits.
LIMITED WARRANTY
Seller warrants that the product hereby purchased is, upon delivery, free from defects in material and
workmanship and that any such product which is found to be defective in such workmanship or material
will be repaired or replaced by Seller (Ex-works, Factory, Watertown, Massachusetts. INCOTERMS); pro-
vided, however, that this warranty applies only to equipment found to be so defective within a period of
24 months from the date of manufacture by the Seller. Seller shall not be obligated under this warranty for
alleged defects which examination discloses are due to tampering, misuse, neglect, improper storage, and
in any case where products are disassembled by anyone other than authorized Seller’s representatives.
EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE, SELLER DISCLAIMS
ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
LIMITATION OF SELLER’S LIABILITY
Seller’s liability to Buyer for any loss or claim, including liability incurred in connection with (i) breach of
any warranty whatsoever, expressed or implied, (ii) a breach of contract, (iii) a negligent act or acts (or
negligent failure to act) committed by Seller, or (iv) an act for which strict liability will be inputted to seller,
is limited to the “limited warranty” of repair and/or replacement as so stated in our warranty of product.
In no event shall the Seller be liable for any special, indirect, consequential or other damages of a like gen-
eral nature, including, without limitation, loss of profits or production, or loss or expenses of any nature
incurred by the buyer or any third party.
UE specifications subject to change without notice.
FGS100005/04
Model 540-543
Models 544-548
Models 560-564
Models 565-567
Dimensions
UNITED ELECTRIC
CONTROLS
180 Dexter Ave. P.O. Box 9143, Watertown, MA 02472-9143 USA
617 926-1000 Fax 617 926-2568
www.ueonline.com

UNITED ELECTRIC
CONTROLS
FEATURES
• Single Switch Output
• Epoxy Coated and Gasketed Cast
Aluminum Enclosure Designed to
meet NEMA 4X
• Tamper-Resistant Set Point “lock”
• Heat Trace and Freeze Protection
Thermostats
• Proof Pressures to
10,000 psi (689,5 bar)
• Adjustable Ranges:
Pressure:
30 “Hg Vac to
5000 psi (-1 to 344,7 bar)
“wc Ranges:
300 “wc Vacuum to 250 “wc Pressure
(-746,7 to 622,3 mbar)
Differential Pressure:
0.2 “wcd to 500 psid
(0,5 mbar to 34,5 bar)
Temperature:
-180 to 650 °F
(-117.8 to 343.3 °C)
PRESSURE, VACUUM, DIFFERENTIAL PRESSURE
AND TEMPERATURE SWITCHES
100B-02
100 Series
100 Series

2 UNITED ELECTRIC CONTROLS 100B-02
100 Series
100B-02 UNITED ELECTRIC CONTROLS 3
100 Series
The 100 Series is a cost-effective pressure and temperature
switch for process plants and OEM equipment. The rugged, one
piece enclosure features a slanted cover for wiring accessibility.
A wide variety of microswitch and process-connection options
make this versatile series ideal for applications requiring a rugged
weather-proof mechanical switch.
Typical applications that utilize the 100 Series are heat tracing, freeze
protection, processing equipment (pumps, compressors), inputs for
annunciator panels, and re suppression systems.
overview features
• UL listed and cUL certi ed.
CE compliant to low voltage
directive and pressure
equipment directive
• Single switch (SPDT or
DPDT) output
• Welded stainless steel
diaphragm models
• Ultra low pressure, “wc models
• Optional sensor material for
corrosive media
• Polished stainless steel sanitary
connection
• Pump switch model with
wide adjustable deadband
100 Series
“Clam shell” design
allows for ease in wiring
(pressure model shown)
Bulb and capillary
temperature model with
manual reset option
Differential
pressure model

2 UNITED ELECTRIC CONTROLS 100B-02
100 Series
100B-02 UNITED ELECTRIC CONTROLS 3
100 Series
SPECIFICATIONS
STORAGE TEMPERATURE -65° to 160°F (-54 to 71°C)
AMBIENT -40° to 160°F (-40 to 71°C); models 520-548, 700-706: 0 to 160°F
TEMPERATURE LIMITS (-18 to 71°C); Set point typically shifts less than 1% of range for a 50°F
(28°C) ambient temperature change
SET POINT REPEATABILITY Temperature models: ± 1% of adjustable range
Pressure models 15623, 171-174, 218, 270-376, 520-535, 540-543, 700-
706, 560-564: ± 1% of adjustable range; models 190-194, 183-189, 483-
494, 544-548, 565-567, 610-680: ±1.5% of adjustable range
Internal set point lock on all pressure models
SHOCK Set point repeats after 15 G, 10 millisecond duration
VIBRATION Set point repeats after 2.5 G, 5-500 Hz
ENCLOSURE Die cast aluminum, epoxy powder coated, gasketed, captive cover screws
ENCLOSURE CLASSIFICATION Designed to meet NEMA 4X requirements
SWITCH OUTPUT One SPDT snap action switch; switch may be wired
“normally open” or “normally closed”
ELECTRICAL RATING 15 A 125/250/480 VAC resistive except for H100-15623, 20A 125/250/
480 VAC resistive, B100-13546 and E100-13545, 22A/480 VAC
WEIGHT 2-7 lbs; Varies with model
ELECTRICAL CONNECTION 1/2” NPT (female); Two 7/8” diameter knockouts
PRESSURE CONNECTION Models 15623, 218, 270-376, 610-680, 701-706: 1/4” NPT (female);
Models: 171-194, 483-494, 520-535: 1/2” NPT (female);
Models 540-548: 1/8” NPT (female); Models 560-564: 2” Sanitary
Fitting; Models 565-567: 1.5” Sanitary Fitting (Sanitary ttings mate
with Tri-Clamp® tting systems)
TEMPERATURE ASSEMBLY Bulb and capillary: 6 feet 304 stainless steel except for E100-13545, 10 feet
304 stainless steel
Immersion stem: nickel-plated brass (standard length only);
optional 316L stainless steel
FILL Models 1BS/BC are solvent lled, models 2-8 non-toxic oil lled
TEMPERATURE DEADBAND Type F typically 1% and type B, C, and E typically 2% of range under
laboratory conditions (70°F ambient circulating bath at rate of 1/2°F
per minute change)
HEAT TRACING OR Thermostats designed specically for heat tracing and freeze protection
FREEZE PROTECTION ambient sensing applications are available with types B100 and E100

4 UNITED ELECTRIC CONTROLS 100B-02
100 Series
100 Series
100B-02 UNITED ELECTRIC CONTROLS 5
100 Series
approvals
pressure model chart
UL listed, cUL certied
Temperature: UL 873, le # E10667
Pressure: UL 508, le # E42272
CE Compliance with Low Voltage Directive (LVD)
CE Compliance with Pressure Equipment Directive (PED 97/23/EC) (Category IV optional)
CE Compliance with ATEX (94/9/EC) Intrinsic safety (ia) (optional)
Russian Approvals
Gosgortechnadzor certication #RRS 04-8897, Intrinsic safety (ia) (optional)
Model Adjustable Set Point Range Deadband Over Range Proof
Low end of range on fall; Pressure* Pressure**
High end of range on rise
“wc mbar “wc mbar psi bar psi bar
Type H100
Buna N diaphragm and O-Ring with 1/2” NPT (female) aluminum pressure connection (other wetted materials available see page 9)
520 300 Vac to 0 -746,7 to 0 0.2 to 8 0,5 to 19,9 200 13,8 400 27,6
521 10 Vac to 10 -24,9 to 24,9 0.1 to 0.6 0,2 to 1,5 200 13,8 400 27,6
522 50 Vac to 50 -124,5 to 124,5 0.1 to 3 0,2 to 7,5 200 13,8 400 27,6
523 0.5 to 5.0 1,2 to 12,4 0.1 to 0.3 0,2 to 0,75 200 13,8 400 27,6
524 2.5 to 50 6,2 to 124,5 0.1 to 0.8 0,2 to 2,0 200 13,8 400 27,6
525 10 to 250 24,9 to 622,3 0.1 to 6 0,2 to 14,9 200 13,8 400 27,6
Welded 316L stainless steel diaphragm with 1/2” NPT (female) 316L pressure connection
530 300 Vac to 0 -746,7 to 0 0.2 to 15 0,5 to 37,3 50 3,4 100 6,9
531 10 Vac to 10 -24,9 to 24,9 0.1 to 0.6 0,2 to 1,5 50 3,4 100 6,9
532 50 Vac to 50 -124,5 to 124,5 0.1 to 3 0,2 to 7,5 50 3,4 100 6,9
533 0.5 to 5.0 1,2 to 12,4 0.1 to 0.3 0,2 to 0,7 50 3,4 100 6,9
534 2.5 to 50 6,2 to 124,5 0.1 to 0.8 0,2 to 2,0 50 3,4 100 6,9
535 10 to 250 24,9 to 622,3 0.1 to 10 0,2 to 24,9 50 3,4 100 6,9
psi bar psi bar psi bar psi bar
Welded 316L stainless steel diaphragm with 1/2” NPT (female) pressure connection, large 0.72” orice for clean-out purposes
171 1 to 20 0,07 to 1,4 0.1 to 1 0,01 to 0,1 500 34,5 1000 68,9
172 2 to 50 0,14 to 3,4 0.1 to 1.5 0,01 to 0,1 500 34,5 1000 68,9
173 4 to 100 0,3 to 6,9 0.1 to 2.5 0,01 to 0,2 500 34,5 1000 68,9
174 8 to 200 0,6 to 13,8 0.1 to 3.5 0,01 to 0,2 500 34,5 1000 68,9
2” sanitary welded 316L stainless steel diaphragm and pressure connection. Mates with Tri-Clamp® tting systems
560 0.5 to 15 0,03 to 1,0 0.1 to 1 0,01 to 0,1 200 13,8 300 20,7
561 1 to 25 0,07 to 1,7 0.1 to 1.5 0,01 to 0,1 200 13,8 300 20,7
562 2 to 50 0,14 to 3,4 0.1 to 2.5 0,01 to 0,2 200 13,8 300 20,7
563 4 to 100 0,3 to 6,9 0.1 to 4 0,01 to 0,3 200 13,8 300 20,7
564 8 to 200 0,6 to 13,8 0.1 to 5 0,01 to 0,3 200 13,8 300 20,7
Tri-Clamp® is a registered trademark of Tri-Clover Inc.
Application Note: The use of metallic diaphragms where higher pressure shock or heavy cycling is expected should be avoided. Models 171-174 should not be used where system or start-up vacuum pressure
might exceed 26” Hg Vac (-0.9 bar). Use of optional diaphragm materials for models 483-489 may increase deadband.

4 UNITED ELECTRIC CONTROLS 100B-02
100 Series
100 Series
100B-02 UNITED ELECTRIC CONTROLS 5
100 Series
1.5” sanitary welded 316L stainless steel diaphragm and pressure connection. Mates with Tri-Clamp® tting systems
565 5 to 30 0,3 to 2,1 1 to 5 0,07 to 0,3 1000 68,9 1500 103,4
566 10 to 100 0,7 to 6,9 1 to 12 0,07 to 0,8 1000 68,9 1500 103.4
567 15 to 300 1,0 to 20,7 3 to 22 0,21 to 1,5 1000 68,9 1500 103,4
Buna N diaphragm and O-Ring with 1/4” NPT (female) nickel-plated brass pressure connection; Option M540 Viton® diaphragm and O-Ring
available for models 701-705
701 1.5 to 30 0,1 to 2 1 to 2 0,07 to 0,14 500 34,5 600 41,4
702 3 to 100 0,2 to 6,9 1 to 4 0,07 to 0,28 500 34,5 600 41,4
703 9 to 300 0,6 to 20,7 1 to 5 0,07 to 0,34 500 34,5 600 41,4
704 15 to 500 1,0 to 34,5 2 to 8 0,14 to 0,55 1500 103,4 2500 172,4
705 30 to 1000 2,1 to 68,9 3 to 20 0,21 to 1,38 1500 103,4 2500 172,4
706 100 to 1700 6,9 to 117,2 10 to 30 0,07 to 2,07 2000 137,9 2500 172,4
Viton® diaphragm and O-Ring with 1/4” NPT (female) 303 stainless steel pressure connection (includes adjustable deadband switch)
15623 20 to 200 1,4 to 13,8 12 to 26 0,8 to 1,8 500 34,5 1000 68,9
316L stainless steel diaphragm (optional Hastelloy® C, Monel® or Tantalum); Viton® GLT O-Ring (optional Kalrez®, Silicone, Ethylene Propylene, or
Aas®); 316 stainless steel 1/2” NPT (female) pressure connection (optional Hastelloy® B or C, or Monel®), large 0.72” orice for clean-out purposes.
Models 188 and 189 have a 316L stainless steel 1/2” NPT (female) pressure connection
183 1 to 20 0,07 to 1,4 0.3 to 2.5 0,021 to 0,2 500 34,5 1000 68,9
184 2 to 50 0,14 to 3,4 0.3 to 3 0,021 to 0,2 500 34,5 1000 68,9
185 4 to 100 0,3 to 6,9 0.5 to 6 0,03 to 0,4 500 34,5 1000 68,9
186 8 to 200 0,6 to 13,8 1 to 11 0,07 to 0,8 500 34,5 1000 68,9
188 50 to 1000 3,4 to 68,9 25 to 125 1,7 to 8,6 2000 137,9 7000 482,6
189 250 to 3500 17,2 to 241,3 50 to 300 3,4 to 20,7 4000 275,8 7000 482,6
Welded 316 stainless steel diaphragm with 1/2” NPT (female) pressure connection, large 0.72” orice for clean-out purposes
Lower 75% range span Top 25% range span
psi bar psi bar psi bar psi bar psi bar
190 5 to 30 0,3 to 2,1 1 to 3 0,07 to 0,2 6 max 0,4 1500 103,4 2500 172,4
191 10 to 100 0,7 to 6,9 1 to 8 0,07 to 0,6 15 max 1,0 1500 103,4 2500 172,4
192 15 to 300 1,0 to 20,7 3 to 18 0,2 to 1,2 25 max 1,7 1500 103,4 2500 172,4
193 20 to 500 1,4 to 34,5 4 to 30 0,3 to 2,1 45 max 3,1 1500 103,4 2500 172,4
194 80 to 1700 5,5 to 117,2 5 to 120 0,3 to 8,3 150 max 10,3 2000 137,9 2500 172,4
Welded 316 stainless steel diaphragm with 1/2” NPT (female) pressure connection, 0.06” orice to dampen pulsations
490 5 to 30 0,3 to 2,1 1 to 3 0,07 to 0,2 6 max 0,4 1500 103,4 2500 172,4
491 10 to 100 0,7 to 6,9 1 to 8 0,07 to 0,6 15 max 1,0 1500 103,4 2500 172,4
492 15 to 300 1,0 to 20,7 3 to 18 0,2 to 1,2 25 max 1,7 1500 103,4 2500 172,4
493 20 to 500 1,4 to 34,5 4 to 30 0,3 to 2,1 45 max 3,1 1500 103,4 2500 172,4
494 80 to 1700 5,5 to 117,2 5 to 120 0,3 to 8,3 150 max 10,3 2000 137,9 2500 172,4
Model Adjustable Set Point Range Deadband Over Range Proof
Low end of range on fall; Pressure* Pressure**
High end of range on rise
psi bar psi bar psi bar psi bar
Type H100
Hastelloy ® is a registered trademark of Haynes International, Inc.
Monel® is a registered trademark of the INCO family of companies.
Viton® and Kalrez® are registered trademarks of Dupont Dow Elastomers.
Aas® is a registered trademark of Asahi Glass, Inc.
* Over Range Pressure: The maximum pressure that may be applied continuously without causing damage and maintaining set point repeatability.
** Proof Pressure:
The maximum pressure to which a pressure sensor may be occasionally subjected, which causes no permanent damage. The unit may require calibration (e.g., start-up, testing).
Deadband Note: Models 190-194, 490-494 are expressed as the lower 75% and top 25% of the range span because of the operating characteristics of the diaphragm sensor and switch.

6 UNITED ELECTRIC CONTROLS 100B-02
100 Series
100B-02 UNITED ELECTRIC CONTROLS 7
100 Series
316L stainless steel diaphragm (optional Hastelloy® C, Monel® or Tantalum) Viton® GLT O-Ring (optional Kalrez®, Silicone, ethylene propylene or Aas®), 316
stainless steel 1/2” NPT (female) pressure connection (optional Hastelloy® B or C, or Monel®), 0.06” orice. Models 488 and 489 316L pressure connection
483 1 to 20 0,07 to 1,4 0.3 to 2.5 0,02 to 0,17 500 34,5 1000 68,9
484 2 to 50 0,14 to 3,4 0.3 to 3 0,02 to 0,2 500 34,5 1000 68,9
485 4 to 100 0,3 to 6,9 0.5 to 6 0,03 to 0,4 500 34,5 1000 68,9
486 8 to 200 0,6 to 13,8 1 to 11 0,07 to 0,8 500 34,5 1000 68,9
488 50 to 1000 3,4 to 68,9 25 to 125 1,7 to 8,6 2000 137,9 7000 482,6
489 250 to 3500 17,2 to 241,3 50 to 300 3,4 to 20,7 4000 275,8 7000 482,6
Phosphor bronze bellows with 1/4” NPT (female) nickel-plated brass pressure connection. Model 218 has 300 series stainless steel spring in media
218 30 ”Hg Vac to 0 -1 to 0 1 to 2 ”Hg 0,03 to 0,07 0 0 30 2.07
270 4 to 200 0,3 to 13,8 1 to 8 0,07 to 0,6 200 13,8 250 17,2
274 6 to 300 0,4 to 20,7 1 to 10 0,07 to 0,7 300 20,7 350 24,1
Welded 316L stainless steel bellows with 1/4” NPT (female) pressure connection
358 15 to 200 1,0 to 13,8 1 to 3 0,07 to 0,2 200 13,8 800 55,2
361 20 to 300 1,4 to 20,7 1 to 4 0,07 to 0,3 300 20,7 800 55,2
376 25 to 500 1,7 to 34,5 1.5 to 5 0,10 to 0,3 500 34,5 800 55,2
303 stainless steel piston, Buna N O-Ring with 1/4” NPT (female) 303 stainless steel pressure connection (Not recommended for gas service since drying of
O-Ring seal can allow bleeding of medium into the atmosphere)
610 75 to 1000 5,2 to 68,9 30 to 150 2,07 to 10,3 6000 413,7 10,000 689,5
612 125 to 3000 8,6 to 206,8 40 to 250 2,76 to 17,2 6000 413,7 10,000 689,5
616 700 to 5000 48,3 to 344,7 40 to 375 2,76 to 25,9 6000 413,7 10,000 689,5
316 stainless steel bellows with 1/4” NPT (female) pressure connection (Not recommended for gas applications or for rapid or high cycling pressure changes)
680 100 to 1700 6,9 to 117,2 9 to 40 0,6 to 2,8 1700 117,2 2500 172,4
pressure model chart
differential pressure model chart
Model Adjustable Set Point Range Deadband Over Range Proof
Low end of range on fall; Pressure* Pressure**
High end of range on rise
psi bar psi bar psi bar psi bar
Type H100 (unless noted) (unless noted)
Model Adjustable Set Point Range Deadband Working Proof
Low end of range on fall; Pressure*** Pressure**
High end of range on rise
“wcd/psid mbar/bar “wc/psi mbar/bar psi bar psi bar
Type H100K
Kapton® Diaphragm, Buna N Sealing diaphragms and epoxy coated aluminum 1/8” NPT (female) pressure connections
540 0.2 to 7 “wcd 0,5 to 17,4 mbar 0.05 to 0.6 “wc 0,1 to 1,5 mbar 200 13,8 400 27,6
541 1 to 20 “wcd 2,5 to 49,7 mbar 0.1 to 1.0 “wc 0,2 to 2,5 mbar 200 13,8 400 27,6
542 5 to 50 “wcd 12,4 to 124,4 mbar 0.2 to 2.5 “wc 0,5 to 6,2 mbar 200 13,8 400 27,6
543 10 to 200 “wcd 24,9 to 497,0 mbar 0.5 to 8 “wc 1,2 to 19,9 mbar 200 13,8 400 27,6
544 2 to 20 psid 0,1 to 1,4 bar 0.1 to 1.3 psi 6,9 to 89,6 mbar 1200 82,7 2500 172,4
545 5 to 50 psid 0,3 to 3,4 bar 0.2 to 2.2 psi 0 to 0,15 bar 1200 82,7 2500 172,4
546 10 to 125 psid 0,7 to 8,6 bar 0.4 to 5.0 psi 0 to 0,34 bar 1200 82,7 2500 172,4
547 50 to 250 psid 3,4 to 17,2 bar 0.8 to 10 psi 0,1 to 0,69 bar 1200 82,7 2500 172,4
548 100 to 500 psid 6,9 to 34,5 bar 2.0 to 15 psi 0,1 to 1,03 bar 1200 82,7 2500 172,4
Kapton® is a registered trademark of E.I. DuPont.

6 UNITED ELECTRIC CONTROLS 100B-02
100 Series
100B-02 UNITED ELECTRIC CONTROLS 7
100 Series
temperature model chart
Model Adjustable Set Max. Temp Scale Stem/Bulb Size‡
Point Range Division
°F °C °F °C °F °C OD x Length
Type B100 Internal adjustment via reference dial Type C100 No reference dial; model 13546 not available
120 0 to 225 -17.8 to 107.2 275 135 10 5 9/16” x 17⁄8” below 1/2 “NPT thread (nickel-plated brass)
121 200 to 425 93.3 to 218.3 475 246.1 10 5 9/16” x 17⁄8” below 1/2 “NPT thread (nickel-plated brass)
13546 15 to 140 -9.4 to 60 160 71.1 5 2 9/16” x 211⁄16” long stainless steel
(Freeze Protection)
Type E100 Stainless steel bulb and capillary; internal adjustment via reference dial
2BSA -120 to 100 -84.4 to 37.8 150 65.5 10 5 3/8 x 25⁄8”
2BSB 30 to 250 -1.1 to 121.1 300 148.9 10 5 3/8 x 25⁄8”
3BS 100 to 400 37.8 to 204.4 450 232.2 10 5 3/8 x 21⁄8”
4BS 25 to 100 -3.9 to 37.8 150 65.5 2 1 3/8 x 63⁄4”
5BS -20 to 80 -28.9 to 26.7 130 54.4 5 2 3/8 x 5”
8BS 350 to 640 176.7 to 337.8 690 365.6 10 5 3/8 x 31⁄4”
13545 25 to 325 -3.9 to 162.8 360 182.2 10 5 1/8 x 115⁄8”
(Heat Tracing)
Copper bulb and capillary
2BCA -120 to 100 -84.4 to 37.8 150 65.5 10 5 3/8 x 258”
2BCB 30 to 250 -1.1 to 121.1 300 148.9 10 5 3/8 x 25⁄8”
3BC 100 to 400 37.8 to 204.4 450 232.2 10 5 3/8 x 21⁄8”
4BC 25 to 100 -3.9 to 37.8 150 65.5 2 1 3/8 x 63⁄4”
5BC -20 to 80 -28.9 to 26.7 130 54.4 5 2 3/8 x 5”
8BC 350 to 640 176.7 to 337.8 690 365.6 10 5 3/8 x 31⁄4”
Type F100 Stainless steel bulb and capillary; no reference dial
1BS -180 to 120 -117.8 to 48.9 170 76.6 N/A 3/8 x 33⁄4”
2BS -125 to 350 -87.2 to 176.7 400 204.4 N/A 3/8 x 25⁄8”
3BS -125 to 500 -87.2 to 260 550 287.8 N/A 3/8 x 21⁄8”
4BS -40 to 120 -40 to 48.9 170 76.6 N/A 3/8 x 63⁄4”
5BS -40 to 180 -40 to 82.2 230 110 N/A 3/8 x 5”
6BS 0 to 250 -17.8 to 121.1 300 148.8 N/A 3/8 x 41⁄2”
7BS 0 to 400 -17.8 to 204.4 450 232.2 N/A 3/8 x 3”
8BS 50 to 650 10 to 343.3 700 371.1 N/A 3/8 x 31⁄4”
Copper bulb and capillary
1BC -180 to 120 -117.8 to 48.9 170 76.6 N/A 3/8 x 33⁄4”
2BC -125 to 350 -87.2 to 176.7 400 204.4 N/A 3/8 x 25⁄8”
3BC -125 to 500 -87.2 to 260 550 287.8 N/A 3/8 x 21⁄8”
4BC -40 to 120 -40 to 48.9 170 76.6 N/A 3/8 x 63⁄4”
5BC -40 to 180 -40 to 82.2 230 110 N/A 3/8 x 5”
6BC 0 to 250 -17.8 to 121.1 300 148.8 N/A 3/8 x 41⁄2”
7BC 0 to 400 -17.8 to 204.4 450 232.2 N/A 3/8 x 3”
8BC 50 to 650 10 to 343.3 700 371.1 N/A 3/8 x 31⁄4”
‡Optional immersion stem lengths and capillary lengths are available.
* Over Range Pressure: The maximum pressure that may be applied continuously without causing damage and maintaining set point repeatability.
** Proof Pressure:
The maximum pressure to which a pressure sensor may be occasionally subjected, which causes no permanent damage. The unit may require calibration (e.g. start-up, testing).
***Working Pressure Range: The pressure range within which two opposing sensors can be safely operated and still maintain set point adjustability provided the difference in pressure between them does not
exceed the designated adjustable range.

8 UNITED ELECTRIC CONTROLS 100B-02
100 Series
100 Series
100B-02 UNITED ELECTRIC CONTROLS 9
100 Series
how to order
BUILDING A PART NUMBER
TYPE DESCRIPTION
PRESSURE Type H100 - One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale
DIFFERENTIAL PRESSURE Type H100K- One SPDT output; epoxy coated enclosure; internal adjustment with “High-Low” reference scale
TEMPERATURE Type B100 - Immersion stem; one SPDT output; internal adjustment with reference dial
Type C100 - Immersion stem; one SPDT output; internal adjustment with no reference
Type E100 - Bulb and capillary; one SPDT output; internal adjustment with reference dial
Type F100 - Bulb and capillary; one SPDT output; internal adjustment with no reference
SWITCH OPTIONS
0140 Gold contacts, 1 A 125 VAC resistive
0500 Close deadband, 5 A 125/250 VAC resistive
NOT AVAILABLE MODELS 520-535
1010 DPDT switch, 10 A 125/250 VAC resistive; deadband and minimum set point will increase.
NOT AVAILABLE TEMPERATURE VERSIONS, TYPE H100K OR MODELS 171-194, 483-567 AND MODEL 680
1070 10 A 125 VDC resistive; deadband and minimum set point will increase
NOT AVAILABLE MODELS 171-194, 483-567
1519 Adjustable deadband, 15 A 125/250/480 VAC resistive; adjustment wheel changes rise setting only. If
adjustment on fall setting is required, use primary adjustment
NOT AVAILABLE TYPES B100, E100 OR MODELS 171-194, 483-494, 540-567, 610-616
1530 External manual reset, 15 A 125/250/480 VAC resistive; latches on rise.
1535 High ambient, 15 A 125/250 VAC resistive; temperatures up to 250°F (145°C).
NOT AVAILABLE MODELS 520-535
1537 Vapor sealed switch, 15 A 125/250 VAC resistive. NOT AVAILABLE MODELS 523, 533
2000 20 A 125/250/480 VAC resistive. NOT AVAILABLE TYPE H100K OR MODELS 520-535
3000 30 A 125/250/480 VAC resistive. NOT AVAILABLE TYPE H100K OR MODELS 171-194, 483-567, 680
Select a Type
Refer to the “Type” section below.
Determine type number based on switch
output, enclosure, adjustment and
reference.
Fill in the type portion of your part
number with the corresponding number.
Select a Model
Refer to the “Model Charts”.
Determine model based on adjustable
range, deadband and proof pressure.
Fill in the model portion of your part
number with the corresponding number.
Select an Option
Refer to the “Options” section.
Determine option number based on
switch output, optional materials or
other product enhancements.
Fill in the option portion of your part
number with the corresponding number.
Leave “option” portion blank if no
options are needed.
FOR MULTIPLE OPTIONS: Call United
Electric Controls.

8 UNITED ELECTRIC CONTROLS 100B-02
100 Series
100 Series
100B-02 UNITED ELECTRIC CONTROLS 9
100 Series
OTHER OPTIONS
M020 Red status light, 115 VAC only
M201 Factory set one switch; specify increasing or decreasing pressure or temperature and setpoint
M277 Range indicated on nameplate in kPa or MPa, factory selected
M278 Range indicated on nameplate in Kg/cm2. NOT AVAILABLE ON TEMPERATURE VERSIONS
M405 European ATEX Intrinsic safety compliance
M406 Flameproof and Intrinic Safety compliance per Russian Gosgortechnadzor
M407 CE compliance to Pressure Equipment Directive (category IV)
M444 Paper ID tag
M446 Stainless steel ID tag & wire attachment
M449 Mounting bracket kit. Required for models 520-535 when surface mounting. Use kit part number
6361-701 for other models
M504 316L stainless steel immersion stem. AVAILABLE MODELS 120, 121 ONLY
M540 Viton® construction (deadband and low end range may increase slightly);
wetted parts include Viton® diaphragm and O-ring plus stainless steel pressure connection.
ON MODELS 610-616 (O-RING ONLY), 701-705, Kapton® diaphragm, Viton® O-Ring and sealing diaphragms
and aluminum pressure connections ON MODELS 540-548
M550 Oxygen service cleaning; internal construction may change
M914 1/2” NPT (female) stainless steel pressure connection. AVAILABLE MODELS 358-376
M921 Brass pressure connection. AVAILABLE MODELS 610-616
6361-704 Surface and Pipe Mounting Hardware (required for model 520-535, 540-548 when surface mounting)
OPTIONAL SENSOR MATERIAL FOR “WC RANGES. AVAILABLE MODELS 520-525
XC001 Aluminum pressure connection, Viton® diaphragm, Viton® O-ring
XC002 Aluminum pressure connection, Kapton® diaphragm, Buna N O-ring
XC003 Aluminum pressure connection, Kapton® diaphragm, Viton® O-ring
XC004 316L Stainless steel pressure connection, 316L stainless steel diaphragm, Viton® O-ring.
(Over range pressure is limited to 100 psi)
XC005 316L Stainless steel pressure connection, Viton® diaphragm, Viton® O-ring
XC006 316L Stainless steel pressure connection, Kapton® diaphragm, Viton® O-ring
XC007 316L Stainless steel pressure connection, Teon® diaphragm, Viton® O-ring
OPTIONAL SENSOR MATERIALS FOR CORROSIVE MEDIA. AVAILABLE MODELS 183-189, 483-489
XD002 Hastelloy C diaphragm
XD003 Monel diaphragm
XD004 Tantalum diaphragm
XP111 Hastelloy B pressure connection
XP112 Hastelloy C pressure connection
XP113 Monel pressure connection
XR211 Kalrez® O-ring
XR212 Silicone O-ring. NOT AVAILABLE MODELS 188-189, 488-489
XR213 Ethylene propylene O-ring
XR214 Aas® O-ring
OPTIONAL FLUSH MOUNT FLANGES. AVAILABLE MODELS 560-567
Other anges (150# and 300#) available, please consult UE. Flanges conform to ANSI B16.5. Maximum pressure is limited by ange rating.
F196 Flush mounted ange, 150#, 1” lap joint, raised face AVAILABLE MODELS 565-567 ONLY
F197 Flush mounted ange, 150#, 2” lap joint, raised face AVAILABLE MODELS 560-564 ONLY
F198 Flush mounted ange, 300#, 1” lap joint, raised face AVAILABLE MODELS 565-567 ONLY
F199 Flush mounted ange, 300#, 2” lap joint, raised face AVAILABLE MODELS 560-564 ONLY
Note: No options are available on Heat Trace and Freeze Protection models 13546 and 13545 or pump switch model 15623 except M201, M444 and M446.

10 UNITED ELECTRIC CONTROLS 100B-02
100 Series
100 Series
100B-02 UNITED ELECTRIC CONTROLS 11
100 Series
options for temperature models
UNION CONNECTORS
Option Replacement Number Description
Brass
W027 SD6213-27 1⁄2” NPT w/ 3⁄4” bushing
W045 SD6213-45 3⁄4” NPT
W051 SD6213-51 1⁄2” NPT
304 Stainless Steel
W028 SD6213-28 1⁄2” NPT w/ 3⁄4” bushing
W046 SD6213-46 3⁄4” NPT
W050 SD6213-50 1⁄2” NPT
THERMOWELLS
For all bulb & capillary switches, except Model 13545
Brass
W075 SD6225-75 1⁄2” NPT with 3⁄4” NPT adapter bushing, 4” BT
W191 SD6225-191 1⁄2” NPT, 4” BT
W118 SD6225-118 1⁄2” NPT with 3⁄4” NPT adapter bushing, 7” BT
W192 SD6225-192 1⁄2” NPT, 7” BT
316 Stainless Steel
W076 SD6225-76 3⁄4” NPT, 4.5” BT
W193 SD6225-193 1⁄2” NPT, 4.5” BT
W119 SD6225-119 3⁄4” NPT, 7.5” BT
W177 SD6225-177 1⁄2” NPT, 7.5” BT
For all immersion stem switches; except Model 13546
W139 SD6225-139 3⁄4” NPT X 1 23/32” BT, BRASS
W140 SD6225-140 3⁄4” NPT X 1 23/32” BT, 316 ST/ST
W000 IMMERSION STEM AND THERMOWELLS
Note: Option W000 is a special Immersion Stem construction that has no external thread. This option ts inside a special thermowell and
is secured with a set-screw.
Option Description
W000 Immersion stem only, Brass
W097 Immersion stem and thermowell. Includes W000 stem and 1⁄2” NPT x 1 23/32” BT Brass thermowell
W099 Immersion stem and thermowell. Includes W000 stem and 1⁄2” NPT x 1 23/32” BT 316 st/st thermowell.
OPTIONAL LENGTHS:
Optional immersion stem lengths to 15” available in brass, with or without 316 st/st thermowell. Consult UE for additional information.
Optional capillary length to *50’ available in copper or 304 st/st. Armor or Teon® capillary protection available to lengths less than or
equal to capillary length. Consult UE for additional information.
*Consult UE regarding repeatability and ambient effects on capillary lengths over 30’.

10 UNITED ELECTRIC CONTROLS 100B-02
100 Series
100 Series
100B-02 UNITED ELECTRIC CONTROLS 11
100 Series
dimensional drawings
All dimensions stated in inches (millimeters)
Types B100, C100, E100, F100, H100, H100K
Pressure Sensors
Models 171-174 Models 183-186, 483-486 Models 188-194, 488-494
Models 520-525
Models 560-564 Models 565-567
Models 540-543 Models 544-548Models 530-535
Dimension A
Models Inches mm NPT
Pressure
171-174 7.50 190,5 1/2
183-186 7.56 192,0 1/2
188, 189 6.62 168,1 1/2
190-194 6.63 168,4 1/2
218-274 6.56 166,6 1/4
358-376 7.03 178,6 1/4
483-486 7.56 192,0 1/2
488, 489 6.62 168,1 1/2
490-494 6.63 168,4 1/2
520-525 8.44 214,4 1/2
530-535 8.00 203,2 1/2
560-564 6.62 168,1 2” Sanitary Fitting
565-567 6.62 168,1 11
/2
” Sanitary Fitting
610-616 7.00 177,8 1/4
680 6.97 177,0 1/4
701-706, 15623 6.56 166,9 1/4
Temperature
120, 121, 13546 9.38 238,2 Immersion stem
1BC-8BC 1BS-
8BS,13545, 8.75 222,23 Bulb & capillary
Differential Pressure
540-548 8.34 211,8 1/8
Models 218-376, 610-706
Temperature Sensors
Models 1BC-8BC, 1BS-8BS, 13545 Models 120,121 Model 13546

RECOMMENDED PRACTICES AND WARNINGS
United Electric Controls Company recommends careful consideration of the
following factors when specifying and installing UE pressure and temperature
units. Before installing a unit, the Installation and Maintenance instructions
provided with unit must be read and understood.
• To avoid damaging unit, proof pressure and maximum temperature limits
stated in literature and on nameplates must never be exceeded, even by
surges in the system. Operation of the unit up to maximum temperature
is acceptable on a limited basis (i.e., start-up, testing) but continuous
operation must be restricted to the designated adjustable range. Excessive
cycling at maximum temperature limits could reduce sensor life.
• A back-up unit is necessary for applications where damage to a primary
unit could endanger life, limb or property. A high or low limit switch is
necessary for applications where a dangerous runaway condition
could result.
• The adjustable range must be selected so that incorrect, inadvertent
or malicious setting at any range point cannot result in an unsafe
system condition.
• Install unit where shock, vibration and ambient temperature uctuations
will not damage unit or affect operation. Orient unit so that moisture does
not enter the enclosure via the electrical connection. When appropriate,
this entry point should be sealed to prevent moisture entry.
• Unit must not be altered or modied after shipment. Consult UE if
modication is necessary.
• Monitor operation to observe warning signs of possible damage to unit,
such as drift in set point or faulty display. Check unit immediately.
• Preventative maintenance and periodic testing is necessary for critical
applications where damage could endanger property or personnel.
• For all applications, a factory set unit should be tested before use.
• Electrical ratings stated in literature and on nameplate must not be
exceeded. Overload on a switch can cause damage, even on the rst
cycle. Wire unit according to local and national electrical codes,
using wire size recommended in installation sheet.
• Do not mount unit in ambient temp. exceeding published limits.
LIMITED WARRANTY
Seller warrants that the product hereby purchased is, upon delivery, free from
defects in material and workmanship and that any such product which is found
to be defective in such workmanship or material will be repaired or replaced by
Seller (Ex-works, Factory, Watertown, Massachusetts. INCOTERMS); provided,
however, that this warranty applies only to equipment found to be so defective
within a period of 24 months from the date of manufacture by the Seller. Seller
shall not be obligated under this warranty for alleged defects which examination
discloses are due to tampering, misuse, neglect, improper storage, and in
any case where products are disassembled by anyone other than authorized
Seller’s representatives. EXCEPT FOR THE LIMITED WARRANTY OF REPAIR
AND REPLACEMENT STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES
WHATSOEVER WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR
PURPOSE.
LIMITATION OF SELLER’S LIABILITY
SELLER’S LIABILITY TO BUYER FOR ANY LOSS OR CLAIM, INCLUDING
LIABILITY INCURRED IN CONNECTION WITH (I) BREACH OF ANY WARRANTY
WHATSOEVER, EXPRESSED OR IMPLIED, (II) A BREACH OF CONTRACT, (III)
A NEGLIGENT ACT OR ACTS (OR NEGLIGENT FAILURE TO ACT) COMMITTED
BY SELLER, OR (IV) AN ACT FOR WHICH STRICT LIABILITY WILL BE INPUTTED
TO SELLER, IS LIMITED TO THE “LIMITED WARRANTY” OF REPAIR AND/OR
REPLACEMENT AS SO STATED IN OUR WARRANTY OF PRODUCT. IN NO EVENT
SHALL THE SELLER BE LIABLE FOR ANY SPECIAL, INDIRECT, CONSEQUENTIAL
OR OTHER DAMAGES OF A LIKE GENERAL NATURE, INCLUDING, WITHOUT
LIMITATION, LOSS OF PROFITS OR PRODUCTION, OR LOSS OR EXPENSES OF ANY
NATURE INCURRED BY THE BUYER OR ANY THIRD PARTY.
UE specications subject to change without notice.
INTERNATIONAL OFFICES
AUSTRALIA
United Electric Controls
(Australia) PTY Ltd
Unit 2, 615 Warrigal Road
Locked Bag 600
Ashburton, Victoria
3147, Australia
Phone: 613-9567-0750
FAX: 613-9567-0755
BELGIUM
United Electric Controls-Europe
G. Van Gervenstraat 19A
B-9120 Beveren-Waas, Belgium
Phone: 32-37554-383
FAX: 32-37552-747
GERMANY
United Electric Controls
An Der Zentlinde 21
D-64711 Erbach, Germany
Phone: 496-062-7400
FAX: 496-062-7501
MALAYSIA
United Electric Controls, Far East
No. 1-2-2, 2nd Floor
Jalan 4/101C
Cheras Business Centre
Batu 5, Jalan Cheras
56100 Kuala Lumpur, Malaysia
Phone: 603-9133-4122
FAX: 603-9133-4155
RUSSIA
United Electric Controls, Moscow
Alyabyeva str., 4-1-4
Moscow, 121309, Russia
Phone: +7 (095) 792-88-06
FAX: +7 (095) 142-34-60
CANADA
EASTERN
68 Mosley Crescent
Brampton, Ontario
Canada L6Y 5C8
Phone: 905-455-5131
FAX: 905-455-5131
WESTERN
148 Silver Ridge Close N.W.
Calgary, Alberta
Canada T3B 3T4
Phone: 403-247-3724
FAX: 403-247-3724
U.S. SALES OFFICES
United Electric Controls
32 Highland Rd.
South Hampton, NH 03827
Phone: 603-394-0078
FAX: 603-394-0175
United Electric Controls
28 N. Wise Ave.
Freeport, IL 61032
Phone: 815-235-3501
FAX: 815-235-3847
United Electric Controls
1022 Vineyard Drive
Conyers, GA 30013
Phone: 770-483-8400
FAX: 770-929-8716
United Electric Controls
5829 Grazing Court
Mason, OH 45040
Phone: 513-398-3175
FAX: 513-398-3076
United Electric Controls
102 Salazar Court
Clayton, CA 94517
Phone: 925-524-0210
FAX: 925-524-0210
United Electric Controls
27 Summit Terrace
Sparta, NJ 07871
Phone: 973-271-2550
FAX: 973-729-6099
United Electric Controls
12630 Summerwood Glen
Houston, TX 77041
Phone: 832-243-0119
FAX: 832-243-0140
FGS3500504
100B-02
UNITED ELECTRIC
CONTROLS
180 Dexter Avenue, P.O. Box 9143
Watertown, MA 02471-9143 USA
Telephone: 617 926-1000 Fax: 617 926-2568
http://www.ueonline.com
This manual suits for next models
2
Table of contents
Other UE Switch manuals
Popular Switch manuals by other brands

Weidmuller
Weidmuller IE-SW-PL16M Series Hardware installation guide

Tekvox
Tekvox TEK 1201-N+ user manual

Elkay
Elkay 350A-1 Fitting & operating instructions

Avocent
Avocent DSR Series DSR1020 Quick installation guide

Broadcast Pix
Broadcast Pix Slate 5000 Series Installation planning guide

Apollo
Apollo HF1000 Specifications