manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. UEi
  6. •
  7. Measuring Instrument
  8. •
  9. UEi DTK2 User manual

UEi DTK2 User manual

Other UEi Measuring Instrument manuals

UEi EM151 User manual

UEi

UEi EM151 User manual

UEi DL429 User manual

UEi

UEi DL429 User manual

UEi DL389B User manual

UEi

UEi DL389B User manual

UEi C165 User manual

UEi

UEi C165 User manual

UEi C161 User manual

UEi

UEi C161 User manual

UEi DTH880 User manual

UEi

UEi DTH880 User manual

UEi DL429B User manual

UEi

UEi DL429B User manual

UEi C160 User manual

UEi

UEi C160 User manual

UEi C165+ User manual

UEi

UEi C165+ User manual

UEi DAFM4 User manual

UEi

UEi DAFM4 User manual

UEi AQM4 User manual

UEi

UEi AQM4 User manual

UEi DL479 User manual

UEi

UEi DL479 User manual

UEi HA1 User manual

UEi

UEi HA1 User manual

UEi DL599 User manual

UEi

UEi DL599 User manual

UEi C163 User manual

UEi

UEi C163 User manual

UEi DT720 User manual

UEi

UEi DT720 User manual

UEi EM720 User manual

UEi

UEi EM720 User manual

UEi DL579 User manual

UEi

UEi DL579 User manual

UEi DL250 User manual

UEi

UEi DL250 User manual

UEi DTH880 User manual

UEi

UEi DTH880 User manual

UEi DT15A User manual

UEi

UEi DT15A User manual

UEi UTL2002 User manual

UEi

UEi UTL2002 User manual

UEi AK940 User manual

UEi

UEi AK940 User manual

UEi C85 User manual

UEi

UEi C85 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

7CE CERTIFICATE
The product complies with EMC directive 2004/108/EC
Technical standard: Emission EN 61326-1:2006 Class B
EN 55011:2009/A1:2010 Group 1 Class B
Immunity EN 61326-1:2006 EN 61000-4-2:2009
EN 61000-4-3:2006 A2:2010
8BATTERY REPLACEMENT
 • Turnofftheinstrument
 • Removethebatterycompartment
 • Changethebattery
 • Replacethecompartmentcover
END OF LIFE
9LIMITEd WARRANTY
TheDTK2iswarrantedtobefreefromdefectsinmaterialsand
workmanshipforaperiodofthreeyearsfromthedateofpurchase.If
withinthewarrantyperiodyourinstrumentshouldbecomeinoperative
fromsuchdefects,theunitwillberepairedorreplacedatUEi’soption.
Thiswarrantycoversnormaluseanddoesnotcoverdamagewhich
occursinshipmentorfailurewhichresultsfromalteration,tampering,
accident,misuse,abuse,neglectorimpropermaintenance.Batteries
andconsequentialdamageresultingfromfailedbatteriesarenot
coveredbywarranty.
Anyimpliedwarranties,includingbutnotlimitedtoimpliedwarranties
ofmerchantabilityandfitnessforaparticularpurpose,arelimited
totheexpresswarranty.UEishallnotbeliableforlossofuseofthe
instrumentorotherincidentalorconsequentialdamages,expenses,or
economicloss,orforanyclaimorclaimsforsuchdamage,expensesor
economicloss.Apurchasereceiptorotherproofoforiginalpurchase
datewillberequiredbeforewarrantyrepairswillberendered.
Instrumentsoutofwarrantywillberepaired(whenrepairable)fora
servicecharge.Returntheunitpostagepaidandinsuredto:
8030SWNimbusAvenue,BeavertonOR97008
 • Accessories,probesandbatteries(NotCoveredbyWarranty)
 • Claimsarenotacceptableforimproperuse(includingadaptation
  toparticularapplicationsnotforeseenintheinstructionmanual
  orimpropercombinationwithincompatibleaccessoriesor
  equipment,orforrepaircarriedoutbyunauthorizedpersonnel.)
1-800-547-5740 • FAX: (503) 643-6322
www.ueitest.com • Email: [email protected]
Thiswarrantygivesyouspecificlegalrights.Youmayalsohaveother
rightswhichvaryfromstatetostate.
DTK2
DTK2
75.9
°
f
7
7
5
5
.
5
.
.
9
.
.
.
9
9
9
°
°
f
f
f
T1
K
T1
T1
K
K
76.1°f
7
7
6.1
6.1
°
°
f
f
f
T2
K
T2
T2
K
K
Differential Thermometer
1-800-547-5740 • Fax: (503) 643-6322
www.ueitest.com • Email: [email protected]
INSTRUCTION MANUAL
ENGLISH
Differential Thermometer
Temperature Units °F / °C
Sensor Type k-type
Range -328°~2498°F(-200°~1370°C)
Accuracy
Range Accuracy
-328°~-58°F(-200°~-50°C) ±(0.1%rdg+4°F(2.2°C))
-58°~1832°F(-50°~1000°C) ±(0.1%rdg+2°F(1°C))
1832°~2498°F(1000°~1370°C) ±(0.1%rdg+4°F(2.2°C))
Accuracy (after ice-
point calibration) 30°~120°F(-1.1~48.9°C) ±1°F(0.6°C)
Resolution 0.1°F/0.1°C
HOLD Yes
Max / Min T1 & T2
Differential (T1-T2) Yes
Operating / Storage
Operating Temperature 32~104°F(0~40°C)
Operating RH% <70%RH,Non-condensing
Storage Temperature -4~140°F(-20~60°C)
Storage RH% <80%RH,Non-condensing
Battery Type 1x9V(NEDA1604)
Battery Life (typical) 125 hours typical
6SPECIFICATIONS
CAUTION:Thissymbolindicatesthat
equipmentanditsaccessoriesshallbesubject
toaseparatecollectionandcorrectdisposal.
WARNING
Ifthesymbol“ “appearsontheLCD,
pleasereplacethebatteryimmediately.
Copyright©2013UEi.AllRightsReserved
06/13 17018
3LCd dISPLAY
 1. PrimaryLCD:DisplayT1(1stthermocouplereading)orT1-T2
 2. SecondaryLCD:DisplayT2
4OPERATION
• POWER ON /OFF
Note:
Make sure you have plugged in the thermocouple probe before
turning on.
PressandholdPWRbuttontoturnonthemeter.Whilethemeteris
on,pressPWRbuttontoturnoffthemeter.
• SLEEP MODE (AUTO POWER OFF)
Themeterwillturnoffautomaticallyafter15minutesifnobuttons
arepressed.Todisableautopowerofffunction,whenthemeter
isoff,pressandhold“HOLD”buttonthenpress“PWR”button
toturnonthemeter,theprimaryLCDshowsthefollowing.Sleep
modeisnowdisabled.
• TAKING MEASUREMENT
Connectthermocouple.Ifprobeisopenornotconnected,theLCD
willshow”---”.
• DIFFERENTIAL (T1 - T2)
Press"MODE"todisplaydifferential.Press"MODE"againto
returntonormaldisplay.
• MAX / MIN
PressMAX / MINbuttontochangeoperationmodefromlive
data->MAX->MIN->backtolivedata.Correspondingvaluewill
displayontheLCD.Thesevalueswillresetatpoweronorwhen
performingaresetonMAX/MIN.
Reset MAX/MIN:PressMax/Minbuttonfor2secondstoreset
MAX/MINanalysisvalue.TheMAX/MINvalueisupdatedto
currentreading.
• DATA HOLD
Freezedisplayofbasicmeasurementsordisable.PressHOLD
buttonagaintogobacktothetemperaturereading.
• CHANGE UNIT
PressUNITbuttontochangeunit˚Cor˚F.Themeterdefault
temperatureunitis˚F.Themeterwilldefaulttolastselectedscale.
1INTROdUCTION
ThankyouforpurchasingtheUEiDTK2dualinputKtype
differentialthermometer.Thisthermometerfeaturesabuilt-in
microprocessorandhighresolutionanalogtodigitalconverter
chip.Thethermocoupleproberespondsveryquicklytoawide
rangeoftemperaturemeasurements.Theindustrystandardmini
thermocouplejackacceptsawideselectionofprobetypes.
FEATURES
•Dualinputwithdifferential(T1-T2)
•Min/Maxcapture(T1&T2)
•Autopoweroffwithdisablefeature(15minutes)
•LargeLCDscreen
•Completewithbeadwiretemperatureprobesand9Vbattery
•˚C/˚Fselectfunction
•Magneticmount
INCLUDES
•Meter
•9Vbattery
•Operationmanual
• ATT29AK-typebeadprobe(2)
• Pouch
2KEYPAd (CONTROLS)
T1
-
T2
HOLD MAX MIN
K
K
2
1
MODE
SET
PWR
MAX
MIN
UNIT
HOLD
PRESS“UNIT”TOSELECT˚C/˚F.
Freezedisplay
Press“MODE”tochangeoperationmodeT1orT1-T2.
Thecorrespondingreadingwilldisplayontheprimary
LCD.ThesecondaryLCDwillalwaysdisplayT2.
Pressandhold“PWR” to turn on the meter or
pressittoturnoffthemeter.Themeterwillturnoff
automaticallyafter15minutesifyoudon’tpressany
key.Press“HOLD”and“PWR”buttonstodisable
Autosleepmode.
Press“MAX/MIN”tochangeoperationmode
fromlivedata->Max.->Min.->backtolivedate.The
correspondingvaluewilldisplayontheLCD.Thevalue
iscalculatedsincepoweredonorreset.
Pressandholdtoenterice-pointcalibration.(Please
refertosection 5toensurecorrectcalibration.) PressUNIT
K
K
K
K
SingleInput:(TopView)
K
K
T2
K
K
MIN
K
K
MAX
K
K
HOLD
K
K
5AUTOMATIC ICE-POINT CALIBRATION
TheDTK2hasanautomaticice-pointcalibrationfunction.Please
followthesestepstocalibrateyourmetertothethermocouple
probes.
• ITEMS NEEDED:
 1. DTK2Thermometer
 2. Twok-typeprobes
 3. Crushedice/watermixture
  (distilledwaterrecommendedifavailable)
• CALIBRATION PROCEDURE
1. ConnectbothprobestotheDTK2
2. Placeprobetipsinthecrushedice/watermixture
3. PowerontheDTK2
4. PressandholdSETforfiveseconds.
 a. Themeterwillenterice-pointcalibrationand0.0°Cwill
  flashonbothT1andT2readings
5. Stirtheicebathwiththeprobessubmergedforoneminute
6. Continuestirringtheice/watermixtureuntilthereadings
 returntonormalmeasurement(flashingwillstop)
 Theice-pointcalibrationisnowcomplete.
DTK2
75.9
°
f
75.9
°
f
T1
K
T1
K
76.1°f
76.1°f
T2
K
T2
K
Differential Thermometer
WARNING! Alwaysconnectthermocouplebeforeturningthe
unitonformostaccuratereadings.
WARNING! Makesuretoplugsensorwithcorrectpolarity.
Donotbealarmediferraticreadingsappearondisplayprior
tonormalmode.
MODE
K
K
K
K