Table of Contents
Product Introduction
Preface
List of items
Product structure chart
Preparation before usage
Power-on
Coding keypad with alarm panel
Keypad installation
Function setting
Enter setting status
Set arm delay
1
1
3-4
Keypad Status instruction 2
5
5
6
7
7
Coding and deleting the RFID tag
RFID tag disarm setting
Change user password
Change administrator password
Factory reset
9
10
11
11-12
12
Keypad usage
Away arm
Disarm
Home/Stay arm
Doorbell
13
14
15
15
Precautions
FAQ
Frequently asked questions
Technical parameters
Technical parameters
Cautions
Maintenance
16
16
17
18

RFID
Preface
Thanks for your purchase. This keypad can be installed at the
entrance. By input password, users can easily operate the keypad to
fulfill functions such as away arm, disarm, home arm, doorbell, RFID
disarm etc.
Keypad Status instruction
List of items
12
Wireless keypad*1 Dry battery AAA*3
User manual*1 Setscrews and screws*2
1.Normal working status: the LED will light on 3 seconds if user press
any numeric keys. After 3 seconds, the LED will light off automatically
if there is no further operation.
2.Dormant status: usually the keypad will enter dormant status if
there is no further operation within 30 seconds.(By Press any button,
the keypad will enter working status. And if the keypad detect battery
in low voltage before dormant status, it will send low voltage signal to
alarm panel.)
3.RFID swiping card status: press button, LED lights on and the
keypad will enter swiping tag status. If the keypad detect the RFID
tag or if there is no tag within 10 seconds, then the keypad will return
to dormant status.
4.Setting status: and then press
button, the keypad will enter functional setting status. The LED will
flash at 500ms. Press button to exit or if there is no operation
within 30 seconds, the keypad will exit from functional setting status
and enter return to dormant status.
Note: if operation is correct, the buzzer will make a sound like .
if operation is wrong, then the buzzer will make two sounds like
.
Under normal working status, press other keys except the
button and numeric keys, the input will end.
Under functional setting status, press button to end the input.
“*”
input Administrator password “#”
“*”
“beep”
“beep, beep”
“*”
“#”

RFID
Doorbell
Buzzer
Tamperproof
switch
Positive and
Negative
electrode for
battery
RFID swiping
tag zone
Home arm button
Away arm button
Disarm button
RFID startup button
Users can buy more RFID tag, one keypad can work
with maximum 60pcs tags.
The keyboard structure
34

Coding keypad with alarm panel
Power-on
Preparation before usage
Close the lower cover and lock screws.
Install the batteries according to the battery
polarity direction indicated
As shown in picture, unscrew the screws
and open the base.
1.The keypad work with three AAA batteries.
Unscrew the screws , open the base and put batteries in keypad.
The keypad should be installed on the door or wall before usage.
Keypad installation
RFID
Default user password:1111.
Fix the setscrews on the door/window/wall.
Buckle the keypad on the setscrews appropriately.
Assemble keypad well, tighten the screws.
56
When alarm panel is under learning status, Arm/Disarm keypadl
twice, then you will see corresponding success feedback on the
alarm panel.(please refer to alarm system's user manual)
Note: if the alarm panel make two sounds like “beep-beep” during coding,
this shows that the keypad have already coded with the alarm panel. Note: keypad will trigger tamper-switch alarm when you take down the
keypad, users can stop alarming of keypad by following disarm operations.

Coding and deleting the RFID tag
RFID
Coding the RFID tag:
Deleting the RFID tag:
Set RFID tag to disarm function setting
Users can open and close the function of swipe RFID tag to disarm.
Open the function of swipe RFID tag to disarm:
910
Enter【*+password+8+#】into learning status→ 4-digits password,
the default password is 1111. Then swiping RFID tag, you will hear
one long beep which means learning success. It will turn into
Standby status after 5 seconds.
:after enter learning status, you could swipe RFID tag
continuously to learn 60 tags in maximum. If tag had already been
learned to alarm panel before, it will sound Beep, Beep, Beep,
Notice
Enter 【*+password+7+#】, you will hear one long Beep which
means delete all tags successfully.
Press * button,keypad light, swipe tag twice, you will hear two Beep
Beep. Then it will send disarm signal to alarm panel.
Enter【*+password+9+NEW password+#】 → old password & new
password should be 4-digits,the default password is 1111
Change user password
RFID

As a kind of accessory in alarm system, keypad is a terminal control tool
and it can replace remote controllers. Users need input users’ password
or Administrator password to use keypad control panel.
Keypad usage
Away arm
When the panel receive the arm signal, its built-in siren will make a sound
and its away arm indicator light on, all alarm zones in the alarm panel
enter the arm status(depend on the alarm panel).
If there is alarm happen, then the panel will make alarm sounds and
automatically send SMS and make call to the users whose phone
numbers have preset in the panel.(depend on the alarm panel)
Disarm
Users can disarm via RFID tag and keypad.
Keypad disarm
Enter【*+password + Disarm button】→ 4-digits password, the
default password is 1111.
You will hear one long Beep, then keypad will transmit disarm signal
to alarm panel for one second.
if you hear two Beep Beep, it means wrong password.Notice:
When the panel receive disarm signal, it will make two sounds, its arm
indicator light off, and its disarm indicator light on.(depend on the alarm
panel)
All alarm zones would enter disarm status, accessories won’t trigger
alarm.(depend on panel)
Swipe RFID tag to disarm
Press * button,keypad light, swipe tag twice, you will hear two Beep
Beep. Then it will send disarm signal to alarm panel.
RFID
11
12
Users need to Away Arm alarm panel when go out of home.
Users can arm the panel at home if the keypad set to have delay arm
function. And users need to leave home before delayed time arrives.
Enter【 *+ password + Away Arm button】→ 4-digits password, the
default password is 1111.
You will hear one long Beep, then keypad will transmit away arm
signal to alarm panel for one second.
if you hear two Beep Beep, it means wrong password.Notice:

Cautions
RFID
Stay arm
Users can Stay Arm alarm panel when at home.
Enter【*+password + Stay Arm button】→ 4-digits password, the default
password is 1111.
You will hear one long Beep, then keypad will transmit stay arm signal to
alarm panel for one second.
Notice: if you hear two Beep Beep, it means wrong password.
When panel receive the stay arm signal, its built-in siren would make a
sound and its stay arm indicator light on.(depend on alarm panel)
Then the alarm panel enter stay arm status.(depend on alarm panel)
Sensors set in the home mode zones would be at disarm status, so that
families can leisurely stay at home and won’t trigger alarm. And sensors
in other zones would be at arm status to defend intruders.
Doorbell
When the keypad under normal work status, users can press
button, and then the keypad will send doorbell signal to the panel.
[doorbell]
When the panel receive the doorbell signal, it will make
sounds.(depend on alarm panel)
“dingdong”
Precautions
Users need to follow below items in order to make the keypad have longer
working life, and also to prevent injury to users and others during
operation.
General instructions
Keypad should coding with panel before usage
It may affect the wireless signal transmission distance when
keypad under low voltage
Keypad powered by 3pcs AAA battery
Please take out the insulation tape inside battery compartment
before operate keypad
Regular routine inspection, timely remove malfunction, avoid
system failure at critical moment
Keypad do not support waterproof and moisture proof function,
keypad should be installed at cool and dry place.
Keypad shell is made from ABS material. Do not exposure keypad
long time, otherwise keypad working time would be shorter.
Forbidden
Keypad is non-explosion-proof product; please do not install it at
where there is combustible and explosive.
Please do not install the keypad near electromagnetic object and the
object which would generate thermal energy such as heaters,
air-condition and microwave.
Decomposition Forbidden
Do not disassemble keypad when users discard it.
Only professionals can disassemble this keypad.
Maintenance
13 14
Users can use soft cloth or paper towels to clean the keypad if there is dust
and marks on its surface.
If there is dirt on keypad, users can use soft cloth with alkaline cleaning
fluid to clean it. Users need to dry the keypad after cleaning.

Frequently asked questions
Phenomenon Cause Solution
No reaction
during operation
Low voltage Change battery
Install Batteries
wrongly in keypad Install batteries in right way
Coding failed
between keypad
and alarm panel
No action on alarm
panel
Ensure panel has turned on
Ensure panel has entered
coding status
Alarm panel make
two sounds like
“beep-beep”
Keypad has coded with panel
(depend on panel)
Cannot use
keypad
control panel
Keypad has not
coding with panel
The distance
between keypad
and panel is
too long
Code the keypad with panel
Make the distance shorter so
that can work
Use signal repeater to longer
the working distance
Cannot use tag
to disarm alarm
panel
Tag has not coded
with keypad
Coding tag with keypad
Disable swipe RFID
tag to disarm
function
Open swipe RFID tag to disarm
function
Close swipe tag
function on keypad
Press [*] button on keypad and
then swipe tag
Cannot set
keypad
functions
Input right Administrator
password, and then press [*]
button to activate keypad
Cannot away
arm/home arm/
disarm alarm
poanel
Did not input
password
Input right Administrator
password and user password
then try to control panel
Did not input
Administrator
password
Product name:
Work power:
Three AAA batteries
Emission current:
≤20mA
Tag quantity that keypad support:
60pcs
Wireless distance:
≥80M (open area, no interference)
Wireless frequency:
868/433Mhz
Shell material:
ABS plastic
Size(length*width*height):
138*89*17mm
Humidity: 80%RH (no condensation)
Standby current:
≤30uA
Working condition:
Temperature: -10℃~55℃
15 16
Technical parameters
wireless keypad

Model
产品型号
Design
设计
印刷尺寸
Print size
工艺
Crafts Saddle stitch -32P
骑马钉-32P
Component name
部件名称 说明书
User manual
Material
材料 克书写纸
Shell writing paper
成品尺寸
Finished size
版本
Version
注:双色、双面印刷
Note: bicolor and dual page print
Table of contents
Popular Keypad manuals by other brands

Honeywell Home
Honeywell Home PROSIXLCDKP Series Installation and setup guide

Fairford
Fairford Synergy SGY-010 installation guide

Risco
Risco RW332KPP400D instructions

S&G
S&G Biometric Keypad Programming and operating instructions

GESS
GESS ACKP50EM-I manual

Doorentryonline
Doorentryonline K401-E user manual