1/6
IP68
No.
Ordering Code
1.
INSTALLATION MANUAL
PRODUCT NAME : VOLGA/1 - CV Ground / Concrete Wall Recess
2.
3.
lll
Glass Temperature
At Ta 50°C
Light Emitting Diodes
(LED)
Input
Last Revised On : 25/09/2023 REV.01 FR-DM-17 REV.03 EFF 15/09/17
1
2 Meters cable pre-wired
from the factory.
ÊÒÂä¿ÂÒÇ2àÁµÃ»ÃСͺÁÒ
¾ÃÍÁ¡ÑºµÑÇâ¤Á¨Ò¡âç§Ò¹
9007-4-2-361-91
-
+
65.5° C TA40°
1-11
112 108
û70
95
9007-A-/6/C/H/U/0/2-429-91
9007-A-/6/C/H/U/0/2-2-430-91
9007-A-/6/C/H/U/0/2-2-431-91
9007-B/C/H/U/0-2-372-91
9007-B/C/H/U/0-2-373-91
9007-B/C/H/U/0-2-374-91
9008-4-2-355-91
9008-A/6/C/H/U/0-2-561-91
4.
5.
6.
7.
8.
9.
9008-A/6/C/H/U/0-2-562-91
9008-A/6/C/H/U/0-2-563-91
Constant Voltage
24V
( Output from SELV
system only)
( ¡ÃÐáÊ俵ͧÁÒ
¨Ò¡Ãкºáç´Ñ¹ä¿¿Ò
µèíÒ¾ÔàÈÉ¢Ñé¹»ÅÍ´ÀÑÂ
à¾Õ§à·Ò¹Ñé¹)
Constant Current
700mA (CC)
Constant Current
1200mA (CC)
10.
11.
2
2.1
2.2
Please note the ground level.
¢ͤÇÃÃÐÇѧ : ¼ÔÇ˹ҢͧµÑÇâ¤Á¡Ñº¼ÔÇ
¾×鹤ÇÃÍÂÙã¹ÃйҺà´ÕÂǡѹ
Cable length 200 mm.
ÊÒÂä¿ÂÒÇ 200 ÁÁ.
105
150x150 Cable conduit
Ø
22mm.
Wire Mesh
85
20-30cm.
50
Unit:mm.
Gravel
Approx size:
34
"
VOLGA/1 - CC Ground / Concrete Wall Recess
61° C TA40°
60° C TA25°
concrete
61° C TA40°
61° C TA40°
60° C TA25°
60° C TA25°
65.5° C TA40°
60° C TA50°
60° C TA50°
60° C TA50°
Accessory available separately./ÍØ»¡Ã³ àÊÃÔÁ¨íÒ˹ÒÂᡵÒ§ËÒ¡ Distance from luminaire to Driver
ÃÐÂзҧ¨Ò¡µÑÇâ¤Á¶Ö§ ä´ÃàÇÍÃ
1.00 mm.
2
1.50 mm.
2
2.00 mm.
2
Ordering Code Product Name Maximum number of luminaires
¨íҹǹâ¤Á㹡ÒõÍ Conductor size / ¢¹Ò´ÊÒÂä¿
Luminaire Wattage
AUN-DRG-0027-00 LED Constant Voltage
Driver 24Vdc 72W. 3.3 W 1-7 luminaire 30 m 50 m 65 m
AUN-DRG-0011-00 LED Constant Voltage
Driver 24Vdc 150W.
AUN-DRG-0024-00 LED Constant Voltage
Driver 24Vdc 200W.
3.3 W 1-11 luminaire 30 m 50 m 65 m
3.3 W 1-13 luminaire 30 m 50 m 70 m
FR-DM-17 REV.03 EFF 15/09/17
Installation complete
¡ÒõԴµÑé§àÊÃç¨ÊÁºÙó
Gel-Filled IP68 Connector Cable Diameter
4.8 - 6mm.
Available Separately
à¨ÅµÍÊÒÂ信ѹ¹éíÒIP68,¢¹Ò´ÊÒÂä¿
Ø
4.8-6ÁÁ.
ᡨíÒ˹ÒµÒ§ËÒ¡
Ordering Code : AUN-CON-0024-00
'See connecting detail on manual.'
´ÙÃÒÂÅÐàÍÕ´·Õè¤ÙÁ×Í¡ÒõԴ
2/6
3
Cable size : 2x1.00 mm. 4.8-6mm.
¢¹Ò´ÊÒÂä¿
74
2
4
Last Revised On : 25/09/2023 REV.01
/ For On-Off, DALI system. OD-9007
Remote driver for 24V system.
ä´ÃàÇÍÃµÔ´µÑ駹͡µÑÇâ¤ÁÊíÒËÃѺÃкºä¿ 24V / ÊíÒËÃѺÃкº à»´-»´ / DALI
+ - + -
Parallel wiring constant voltage
+ -
+
-
Input/à¢Ò
220-240 V
~
L
N
AC DC
Luminaires 1-n
12n
Output/ÍÍ¡
24 V
( Output from SELV system only)
(¡ÃÐáÊ俵ͧÁÒ¨Ò¡Ãкºáç´Ñ¹ä¿¿Ò
µèíÒ¾ÔàÈÉ¢Ñé¹»ÅÍ´ÀÑÂà¾Õ§à·Ò¹Ñé¹)
Warning
Please ensure that the led lamp is connected to the driver correctly.
Wrong polarity connection cause a damage to the led lamp and driver.
â»Ã´ÃÐÇѧ¡ÒõÍÊÒÂä¿ÊÅѺ¢ÑéÇ +ºÇ¡ -ź ¨Ò¡ä´ÃàÇÍÃÁÒà¢Ò·ÕèËÅÍ´ LED ËÒ¡µÍÊÅѺ¢ÑéÇ
¨Ð·íÒãËä´ÃàÇÍÃáÅÐËÅÍ´ LED à¡Ô´¤ÇÒÁàÊÕÂËÒÂ
1. 1.
2.
3.
4.
5.
2.
Remark :
ËÁÒÂà˵Ø
Installation should be carried out by a qualified
electrician in accordance with appropriate national
wiring regulation.
¡ÒõԴµÑé§â¤Áä¿¿ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´ÂªÒ§ä¿¿Ò
·ÕèÁÕ¤ÇÒÁÃÙáÅФÇÒÁªíÒ¹Ò 㹡ÒõԴµÑé§ÍØ»¡Ã³ä¿¿Ò
â´Â੾ÒеÒÁÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿Ò
Disconnect the power before changing the lamp.
»´ÊÇÔ·ªä¿·Ø¡¤ÃÑé§·Õèà»ÅÕè¹ËÅÍ´ä¿
For Class1 luminaire, the installation must be
completed with earthing.
ÊíÒËÃѺâ¤Áä¿·ÕèÁÕ¡Òûͧ¡Ñ¹ä¿¿Òà ÑèÇÃдѺ1
¡ÒõԴµÑé§µͧµÍÊÒ´ԹµÒÁÁÒµÃฐÒ¹¤ÇÒÁ»ÅÍ´ÀÑ´ÇÂ
Do not exceed the maximum wattage.
ËÒÁãªËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµà¡Ô¹¡ÇÒ·ÕèÃÐºØ ËÃ×ÍãªËÅÍ´¼Ô´»ÃÐàÀ·
Don't touch LED while maintaining or cleaning.
ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃØ§ÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´
Warning :
¢ͤÇÃÃÐÇѧ
The manufacturer will not be liable or held responsible
for any incorrect installation, misuse or improper use
and unauthorised modification to the fittings. Failure
to comply with mentioned warning may cause serious
damage or serious injury to persons, animals or
objects. If any modification is required please consult
your dealer for the details.
·Ò§¼Ù¼ÅÔµäÁÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡
¡ÒõԴµÑé§äÁ¶Ù¡ÇÔ¸Õ,ãª§Ò¹¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Á
ã¹·Ø¡¡Ã³Õ«Öè§ ÊÔè§¼Ô´»¡µÔàËÅÒ¹Õ  ÍÒ¨·íÒãËà¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊÑµÇ 
ÊÔ觢ͧ ËÒ¡ÁÕ¢ÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµ ͧ¡ÒûÃѺáµ§µÑÇâ¤Á
ãËàËÁÒÐÊÁ¡Ñº¡ÒÃãª§Ò¹¡ÃسҵԴµ͵ÑÇá·¹¨íÒ˹ÒÂËÃ×ͼÙ¼ÅÔµ
Where damage has occured to the fittings, please
make the replacement with standard parts before use.
㹡óշÕèÁÕªÔé¹Êǹ»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒÂ¡ÃØ³Òà»ÅÕè¹
ªÔé¹ÊǹãËÁ¡͹¡ÒÃãª§Ò¹·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑÂ
For Constant Current 700mA/1200mA (Remote driver) OD-9008
+ -
+
-
Input/à¢Ò
220-240 V
~
L
N
AC DC
1
Output/ÍÍ¡
700mA/1200mA
( Output from SELV system only)
(¡ÃÐáÊ俵ͧÁÒ¨Ò¡Ãкºáç´Ñ¹ä¿¿Ò
µèíÒ¾ÔàÈÉ¢Ñé¹»ÅÍ´ÀÑÂà¾Õ§à·Ò¹Ñé¹)
Warning
Please ensure that the led lamp is connected to the driver correctly.
Wrong polarity connection cause a damage to the led lamp and driver.
â»Ã´ÃÐÇѧ¡ÒõÍÊÒÂä¿ÊÅѺ¢ÑéÇ +ºÇ¡ -ź ¨Ò¡ä´ÃàÇÍÃÁÒà¢Ò·ÕèËÅÍ´ LED ËÒ¡µÍÊÅѺ¢ÑéÇ
¨Ð·íÒãËä´ÃàÇÍÃáÅÐËÅÍ´ LED à¡Ô´¤ÇÒÁàÊÕÂËÒÂ
Accessory available separately./ÍØ»¡Ã³ àÊÃÔÁ¨íÒ˹ÒÂᡵÒ§ËÒ¡ Distance from luminaire to Driver
ÃÐÂзҧ¨Ò¡µÑÇâ¤Á¶Ö§ ä´ÃàÇÍÃ
1.00 mm.
2
1.50 mm.
2
2.00 mm.
2
Ordering Code Product Name Maximum number of luminaires
¨íҹǹâ¤Á㹡ÒõÍ Conductor size / ¢¹Ò´ÊÒÂä¿
Luminaire Wattage
AUN-GOP-0101-01 LED Constant Current
Driver 700mA 4W. In
IP67 GFR Polymer Box
(On-Off).
2.2 W 1 luminaire 55 m 85 m 110 m
AUN-DRG-0012-00 LED Constant Current
Driver 700mA 20W. In
IP67 GFR Polymer Box
(DALI)
2.2 W 1-3 luminaire 55 m 80 m 110 m
AUN-DRG-0007-00 LED Constant Current
Driver 1200mA 6W. In
IP67 GFR Polymer Box
(On-Off).
3.9 W 1 luminaire 10 m 15 m 20 m
FR-DM-17 REV.03 EFF 15/09/17
3/6
Last Revised On : 25/09/2023 REV.01
Place the gravel 200-300 mm.depth underneath the casing for water drainage
(Pic-1).Then do the testing by filling water into the casing and let it drain.The
water should be drained out by 30 minutes.
If not,the additional drainage pipe or other system must be applied
(Pic-2)
¤ÇÃÇÒ§¡͹¡ÃÇ´ãµ¡Åͧ½§¾×é¹·ÕèÃÐÂÐÅÖ¡»ÃÐÁÒ³ 200-300 ÁÁ. à¾×èͪ ÇÂÃкÒÂ
¹éíÒ·Õè·ÇÁ¢Ñ§µÑÇâ¤Áä¿ ÊÒÁÒö·´Êͺ¡ÒÃÃкÒ¹éíÒâ´Âà·¹éíÒãÊ¡ÅͧãËàµçÁ
¹éíҨеͧÃкÒÂÍÍ¡ËÁ´ÀÒÂã¹àÇÅÒ 30¹Ò·Õ ËÒ¡äÁà»¹µÒÁ¹Ñ鹤ÇÃÁÕ¡ÒõÍ
·ÍÃкÒ¹éíÒà¾ÔèÁàµÔÁ
General installation guide ( highly recommended)
¢Íá¹Ð¹íÒ㹡ÒõԴµÑé§
Pic-1
ÃÙ»-1
Cable conduit
·ÍÊÒÂä¿
Pic-2
ÃÙ»-2
200-300mm.
Water drainage
conduit.
·͹éíÒ·Ôé§
Installation should not be done under high humidity environment i.e.
rainy day or after the rain,foggy weather....ect.
äÁ¤ÇõԴµÑé§â¤Áä¿ã¹ªǧ·ÕèÁÕ¤ÇÒÁª×é¹ÊÙ§àª¹ Çѹ·Õè½¹µ¡µÅÍ´ËÃ×͵ Ô´µÑé§ËÅѧ
½¹ËÂØ´µ¡à¾ÃÒШзíÒãË¤ÇÒÁª×é¹¶Ù¡¢ ѧäÇã¹µÑÇâ¤Áä¿ËÅѧ¨Ò¡¹Ñ鹨Ðà¡Ô´¡ÒÃ
¤Çºá¹¹à»¹ÅÐÍͧËÃ×ÍË´¹éíÒà¡ÒеԴºÃÔàdzãµ¡ÃШ¡ÀÒÂã¹µÑÇâ¤Áä¿
Do not let the exposed part of the fittings be covered by the soil,dried weed or
foliage as well as corrosive or aggressive substancechemicals.
ÍÂÒ»ÅÍÂãËÁÕÊÔè§Ê¡»Ã¡àª¹ àÈÉ´ Ô¹ ãºäÁ ËÃ×Í
ËÒáË§ÃÇÁ¶Ö§à¤ÁÕ·Õèà»¹ÊÒÃ-¡Ñ´¡Ã͹ÁÒ»¡¤ÅØÁÊÐÊÁºÃÔàdz˹Ò¾×é¹¼ ÔǵÑÇâ¤Áä¿
Do not throw or drop any hard objects onto the top of fittings.
ÍÂÒãËÇѵ¶Ø·Õèà»¹¢Í§á¢ç§ËÅ¹ ËÃ×͵¡¡ÃÐá·¡ãÊºÃÔàdz˹Ò¾×é¹¼ÔǢͧµÑÇâ¤Á
The surface temperature of the fitting can be very high after continuation in
service.
àÁ×èÍà»´ä¿·Ôé§äÇã¹ÃÐÂÐàÇÅÒ˹Ö觨Ðà¡Ô´¤ÇÒÁÃ͹ÊÐÊÁºÃÔàdz´Ò¹º¹¢Í§µÑÇâ¤Á俤ÇÃÃÐÁÑ´ÃÐÇѧ¡ÒÃ
ÊÑÁ¼Ñʶ١ºÃÔàdz´Ñ§¡ÅÒÇ
Proper use of this fitting must be observed.
¤ÇþԨÒóҤÇÒÁàËÁÒÐÊÁ¢Í§¾×é¹·ÕèËÃ×͵íÒá˹§·Õè¨ÐµÔ´µÑé§µÑÇâ¤Áä¿ µÑÇÍÂÒ§ àª¹ ÁÕ
¹éíҢѧà»¹»ÃШíÒ㹺ÃÔàdz¹Ñé¹ËÃ×ÍäÁ? , Çѵ¶ØµÒ§æ àª¹
´Ô¹,àÈÉãºäÁãºËÒÁÕâÍ¡ÒÈ·Õè¨ÐÁÒ»¡¤ÅØÁÊÐÊÁº¹Ë¹Òâ¤Áà»¹»ÃÔÁÒ³ÁÒ¡ËÃ×ÍäÁ?
áÅÐäÁ¤ÇõԴµÑé§ã¹ºÃÔàdz·ÕèÍÒ¨ÁÕâÍ¡Òȶ١ÊÑÁ¼ÑÊâ´Â¤¹ â´Â੾ÒÐà´ç¡àÅç¡ËÃ×ÍÊѵÇàÅÕé§
FR-DM-17 REV.03 EFF 15/09/17
4/6
YES/¶Ù¡µͧ NO/äÁ¶Ù¡µͧ NO/äÁ¶Ù¡µͧ
Last Revised On : 25/09/2023 REV.01
The luminaire should be positioned so that prolonged staring into the luminaire at
a distance closer than 0.5m in not expected.
µíÒá˹§·ÕèµÔ´µÑ駴ǧâ¤Á¤ÇÃÍÂÙ㹨ش·ÕèáʧäÁÊͧà¢ҴǧµÒâ´ÂµÃ§à»¹àÇÅÒ¹Ò¹ ËÒ¡à¢Òã¡Åã¹
ÃÐÂйÍ¡ÇÒ 0.5 Á.
Any damaged safety glass cover must be replaced only with the original
spare part.
àÁ×èÍ¡ÃШ¡à¡Ô´¤ÇÒÁàÊÕÂËÒ à¾×èͤÇÒÁ»ÅÍ´ÀѤÇÃÊÑè§ÍÐäËÅá·¨Ò¡¼Ù¼ÅÔµà·Ò¹Ñé¹
Not using chemical compounds and aggressive agents such as , weed repellents
fertilizers , acid solvent and contaminated irrigation water near the Luminaires.
ËÒÁãªÊÒÃà¤ÁÕàª¹ »ØÂ, ÂÒ¡íҨѴÈѵÃپת, »Ù¹¢ÒÇ, ÊÒÃÅÐÅÒ·Õèà»¹¡Ã´ áÅйéíÒ»¹à»͹ÊÒÃà¤ÁÕ
ºÃÔàdz·ÕèµÔ´µÑé§â¤Áä¿
NO
LED
Our products are installed with electronic components with the protection against
overvoltage according to IEC 61547. The customers have to install the additional
overvoltage protection devices (against surge, transients, etc) in their electrical
system to avoid the risk of damage.
Failing to do so will end the product warranty.
¼ÅÔµÀѳ±¢Í§àÃÒÁÕ¡ÒõԴµÑé§ÍØ»¡Ã³ÍÔàÅç¡·Ã͹ԡÊÊíÒËÃѺ¡Òûͧ¡Ñ¹áç´Ñ¹ä¿à¡Ô¹µÒÁÁÒµÃฐÒ¹
IEC 61547 áÅÐÅÙ¡¤ÒµͧµÔ´µÑé§ÍØ»¡Ã³»ͧ¡Ñ¹áç´Ñ¹ä¿à¡Ô¹à¾ÔèÁàµÔÁ
(»ͧ¡Ñ¹ä¿¡ÃЪҡ ,ä¿¿ÒÅѴǧ¨Ã ÏÅÏ) ã¹Ãкºä¿¿Ò´Ç à¾×èÍËÅÕ¡àÅÕ觤ÇÒÁàÊÕè§·Õè¨Ðà¡Ô´¤ÇÒÁ
àÊÕÂËÒ ËÒ¡äÁ´íÒà¹Ô¹¡Òôѧ¡ÅÒÇ ¡ÒÃÃѺ»ÃСѹ¨ÐÊÔé¹Êشŧ
Clean the products regularly to maintain good light output and prolong surface
quality .
Only use solvent-free cleaning solutions on the products.
·íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ±à»¹»ÃШíÒà¾×èÍÃÑ¡ÉÒ¤ÇÒÁÊͧÊÇÒ§·Õè´ÕáÅÐÂ×´ÍÒÂØ¤Ø³ÀÒ¾¾×é¹¼ÔÇ
ãª¹éíÒÂÒ·íÒ¤ÇÒÁÊÐÍÒ´·ÕèäÁÁÕáÍÅ¡ÍÎÍÅËÃ×͵ÑÇ·íÒÅÐÅÒ¡Ѻ¼ÅÔµÀѳ±à·Ò¹Ñé¹
Cable Size/¢¹Ò´ÊÒÂä¿ : 2x1.00 mm.
Ø
4.8-6 mm.
2
In case the supply cable is exposed to sunlight use UV resistant cable.
¡Ã³Õ·ÕèÁÕ¡ÒõԴµÑé§â¤Á俹͡ÍÒ¤Òà ËÃ×Íâ¤Áä¿·ÕèÁÕ¡ÒÃá¼ÃѧÊÕÂÙÇÕ ÊÒÂ俵ͧÊÒÁÒö»ͧ¡Ñ¹ ËÃ×Í ÁÕ¡Òûͧ¡Ñ¹äÁãË¶Ù¡ÃѧÊÕÂÙÇÕä´
FR-DM-17 REV.03 EFF 15/09/17
5/6
Walk over fittings. Max 500 Kg. constant pressure load.
â¤Ã§ÊÃÒ§¢Í§â¤Á俪¹Ô´¹ÕéÊÒÁÒöà´Ô¹àËÂÕºº¹Ë¹Òâ¤Áä´ áÅÐà Ѻáç¡´·Ñºä´ 500 ¡¡.
For
On-Off System
ÊíÒËÃѺ Ãкºà»´-»´
Last Revised On : 25/09/2023 REV.01
NO
Do not use a high pressure washer to clean the products.
ËÒÁãªà¤Ã×èͧ©Õ´¹éíÒáç´Ñ¹Ê٧㹡Ò÷íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ±
FR-DM-17 REV.03 EFF 15/09/17
6/6
Environmental protection: Waste electrical products should not be disposed of
with household waste. please recycle where facilities exist.check with your local
authority or retailer for recycling advice According to directive 2002/96/CE and
directive 2012/19/EU Waste Electrical and Electronic Equipment (WEEE).
ËÒÁ·Ôé§¼ÅÔµÀѳ±¹ÕéÃÇÁ¡Ñº¢ÂÐ㹤ÃÑÇàÃ×͹ª¹Ô´Í×è¹æàÁ×èÍÊÔé¹ÊØ´ÍÒÂØ¡ÒÃãª§Ò¹â»Ã´á¡¼ÅÔµÀѳ±ÍÍ¡
¨Ò¡¢Í§àÊÕ»ÃÐàÀ·Í×è¹æáÅÐÃÕä«à¤ÔÅÍÂÒ§àËÁÒÐÊÁà¾×èÍÊ§àÊÃÔÁ¡ÒùíÒ·ÃѾÂҡáÅѺÁÒãª«éíÒ«Ö觨ЪÇÂ
»ͧ¡Ñ¹ÍѹµÃÒµÍÊÔè§áÇ´ÅÍÁËÃ×ÍÊØ¢ÀÒ¾¢Í§Á¹ØÉÂ·Õèà¡Ô´¨Ò¡¡Ò÷Ôé§¢ÂÐâ´ÂäÁÁÕ¡ÒäǺ¤ØÁ
ÍÒ§ÍÔ§µÒÁÃÐàºÕº 2002/96/CE áÅÐÃÐàºÕº 2012/19/EU Waste Electrical and
Electronic Equipment (WEEE).
LED LED
To replace the LED module or the entrire luminaire.Please consult your
sales representative.
ËÒ¡µͧ¡ÒÃà»ÅÕè¹ LED
module
ËÃ×Íâ¤Áä¿â»Ã´µÔ´µ͵ÑÇá·¹¢Ò¢ͧ¤Ø³
1.
2.
3.
4.
5.
6.
Replacing the LED module
ÇÔ¸Õ¡ÒÃà»ÅÕè¹ LED module
Contact your sales representative for replacement LED modules. Make sure that the replacement module
match the initially supplied module. Note the part number printed on the LED module.
àµÃÕÂÁ LED module ãËµÃ§¡ÑºÃØ¹· Õèµͧ¡ÒÃà»ÅÕè¹â´ÂµÃǨÊͺ·ÕèËÁÒÂàÅ¢·Õè¾ÔÁ¾º¹LED modules áÅÐ µÔ´µ͵ÑÇá·¹¢ÒÂà¾×èÍÊÑè§«×éÍ
LED modules ·Õèµͧ¡ÒÃà»ÅÕè¹
The LED module can be replaced by qualified persons using standard tools.
¡ÒÃà»ÅÕè¹ LED module µͧ·íÒâ´ÂªÒ§¼ÙªíÒ¹ÒáÅÐãªà¤Ã×èͧÁ×Í·Õèä´ÁÒµÃฐÒ¹
Disconnect power before opening the luminaire housing.
µÑ´áËÅ§¨ÒÂä¿¡͹·Õè¨Ðà»´µÑÇâ¤Á
Replace the old LED module with the new LED module. Reapply thermal interface material as supplied with the
new LED module.
¶Í´ LED module ·ÕèªíÒÃØ´ÍÍ¡ ¨Ò¡¹Ñ ¹·íÒ¤ÇÒÁÊÐÍÒ´¨Ø´ÇÒ§ËÅÍ´ áÅǨ֧·íÒ¡ÒûÃСͺ LED module ãËÁ áÅе ͧà»ÅÕè¹
á¼¹Thermal Pad ËÃ×Í Thermal Grease ´Ç·ء¤ÃÑé§
Inspect gaskets and if required replace with new gaskets. Defective luminaire covers must be replaced. Inspect
correct wiring of replaced LED module.
µÃǨÊͺ»ÃÐà¡ç¹áÅЪÔé¹Êǹ¢Í§µÑÇâ¤Á ¶ÒªíÒÃØ´àÊÕÂËÒÂãË·íÒ¡ÒÃà»ÅÕè¹ãËÁ áÅеÃǨÊͺ¡ÒÃà¢ÒÊÒÂ俢ͧ LED module
·Õèà»ÅÕè¹ãËÁ¶Ù¡µͧËÃ×ÍäÁ
Close the luminaire housing before reconnecting power.
»´½Ò¤ÃͺÅçͤâ¤Áä¿ãËàÃÕºÃÍ¡͹à»´ä¿
Last Revised On : 25/09/2023 REV.01
NO

This manual suits for next models

10

Other Unilamp Outdoor Light manuals

Unilamp AGAR Prismatic User manual

Unilamp

Unilamp AGAR Prismatic User manual

Unilamp TOWER3 User manual

Unilamp

Unilamp TOWER3 User manual

Unilamp FLEXILINK User manual

Unilamp

Unilamp FLEXILINK User manual

Unilamp Mini CHARISMA1 Square-Bollard User manual

Unilamp

Unilamp Mini CHARISMA1 Square-Bollard User manual

Unilamp BRUDA User manual

Unilamp

Unilamp BRUDA User manual

Unilamp MEGA SONIC-ARM User manual

Unilamp

Unilamp MEGA SONIC-ARM User manual

Unilamp 5505-0-3-873 Series User manual

Unilamp

Unilamp 5505-0-3-873 Series User manual

Unilamp QUARK Square - Asymmetric User manual

Unilamp

Unilamp QUARK Square - Asymmetric User manual

Unilamp PILLAR/1 User manual

Unilamp

Unilamp PILLAR/1 User manual

Unilamp CONE 3 User manual

Unilamp

Unilamp CONE 3 User manual

Unilamp HEXAHEDRON User manual

Unilamp

Unilamp HEXAHEDRON User manual

Unilamp ZET1 User manual

Unilamp

Unilamp ZET1 User manual

Unilamp SKUNA - Short Bollard Slim Base User manual

Unilamp

Unilamp SKUNA - Short Bollard Slim Base User manual

Unilamp Small SIROCCO User manual

Unilamp

Unilamp Small SIROCCO User manual

Unilamp SIROCCO User manual

Unilamp

Unilamp SIROCCO User manual

Unilamp SABER/1 User manual

Unilamp

Unilamp SABER/1 User manual

Unilamp ATOM - CC Spotlight User manual

Unilamp

Unilamp ATOM - CC Spotlight User manual

Unilamp CASA User manual

Unilamp

Unilamp CASA User manual

Unilamp Mini PETINA 1 User manual

Unilamp

Unilamp Mini PETINA 1 User manual

Unilamp VAREE User manual

Unilamp

Unilamp VAREE User manual

Unilamp ZOUK2 User manual

Unilamp

Unilamp ZOUK2 User manual

Unilamp XEON Cross User manual

Unilamp

Unilamp XEON Cross User manual

Unilamp KUBIK OD-5951 User manual

Unilamp

Unilamp KUBIK OD-5951 User manual

Unilamp Mini Quark Round User manual

Unilamp

Unilamp Mini Quark Round User manual

Popular Outdoor Light manuals by other brands

urban ambiance UQL1380 installation instructions

urban ambiance

urban ambiance UQL1380 installation instructions

HURAKAN HKN-DL775 manual

HURAKAN

HURAKAN HKN-DL775 manual

ProLights TABLEDW user manual

ProLights

ProLights TABLEDW user manual

Original BTC Davey Lighting 7684 instruction manual

Original BTC

Original BTC Davey Lighting 7684 instruction manual

WE-EF KTY234 LED Installation and maintenance instructions

WE-EF

WE-EF KTY234 LED Installation and maintenance instructions

Portfolio 00605 quick start guide

Portfolio

Portfolio 00605 quick start guide

Quoizel LaSalle LLE8409WT Assembly instruction sheet

Quoizel

Quoizel LaSalle LLE8409WT Assembly instruction sheet

LIGMAN SMITH 1 installation manual

LIGMAN

LIGMAN SMITH 1 installation manual

agrobrite FLF27DLED Assembly instructions

agrobrite

agrobrite FLF27DLED Assembly instructions

Orbegozo LP 2500 instruction manual

Orbegozo

Orbegozo LP 2500 instruction manual

iGuzzini 6136 manual

iGuzzini

iGuzzini 6136 manual

LIGMAN LADOR 44 installation manual

LIGMAN

LIGMAN LADOR 44 installation manual

Geelli ailis eva user manual

Geelli

Geelli ailis eva user manual

BEGA 88 214 Instructions for use

BEGA

BEGA 88 214 Instructions for use

Blooma Nashua 7700511425 manual

Blooma

Blooma Nashua 7700511425 manual

dtm SLIM3 ECO LED Operation and assembly manual

dtm

dtm SLIM3 ECO LED Operation and assembly manual

Monzana Krysante GHWLK220 manual

Monzana

Monzana Krysante GHWLK220 manual

JONATHAN Y JYL5026A manual

JONATHAN Y

JONATHAN Y JYL5026A manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.