manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Unilamp
  6. •
  7. Outdoor Light
  8. •
  9. Unilamp ZET1 User manual

Unilamp ZET1 User manual

1/5
IP67
No. Ordering Code
1.
2.
lll
Light Emitting Diodes
(LED)
9002/9004/9011/9021-0-2-917-91 ***
9002/9004/9011/9021-0-2-920-91 ***
Glass Temperature
At Ta 50°C
63.5° C
63.5° C
INSTALLATION MANUAL
PRODUCT NAME : ZET1 - Frost, ZET2 - Frost,
: ZET1 - Clear,ZET2 - Clear
1
2.3
2.2
2.4
Do not cut or
disconnect the cable
between this area.
ËÒÁµÑ´µÍÊÒÂ俺ÃÔàdz¹Õé
ZET1 - Frost/ZET1 - Clear ZET2 - Frost/ZET2 - Clear
173
û129
173
130
130
130
2.1
9011/9021-0-2-915/916/918/919-91 *** 63.5° C
3.
4.
5.
6.
Last Revised On : 26/10/2020 REV.07 FR-DM-17 REV.03 EFF 15/09/17
Input
Constant Current
350mA (CC)
7.
1-5
Light Emitting Diodes
(LED)
6-7
∅122
170
Please note the ground level.
¢ͤÇÃÃÐÇѧ: ¼ÔÇ˹Ò ¢Í§µÑÇâ¤Á¡Ñº
¼ÔǾ×鹤ÇÃÍÂÙã¹ÃйҺà´ÕÂǡѹ
Cable size : 3x1.00 mm. 7∅-12mm.
¢¹Ò´ÊÒÂä¿
306
256
2
For class I
9011/9021-A/C/D-2-528/529/530-91 ***8.
9002/9004-0-2-528/529/530-91 ***
Constant Current
1050mA (CC)
9.
2
3
59.5° C /Ta 40°
59.5° C /Ta 40°
9002/9004-0-2-522-91 ***
9011/9021-0-2-520/521/522-91 ***
65.8° C
65.8° C
9002/9004-0-3-869/870-91 *
9011/9021-5/7-3-869/870-91 *
62.4° C
62.4° C
+
-
Light Emitting Diodes
(LED)
8-9
220-240V
50-60Hz
2/5
lll
3
∅122
170
Cable size : 2x1.00 mm. 6∅-13mm.
¢¹Ò´ÊÒÂä¿
256
2
For class III
4
PRI SEC
PRI SEC
Output/ÍÍ¡
Input/à¢Ò 220/240 V
Please prepare the space for installation.
¤ÇÃàµÃÕÂÁ¾×é¹·Õèà¼×èÍÊíÒËÃѺ¡ÒõԴµÑé§äÇ´ÇÂ
Transformer/LED Driver box
available separately
¡ÅͧËÁÍá»Å§/LED ä´ÃàÇÍÃ
ᡨíÒ˹ÒÂ
Input
à¢Ò Out
ÍÍ¡
Distance from the luminaire to transformer
/Driver should not exceed 10 meters.
ÃÐÂÐËÒ§ÃÐËÇÒ§µÑÇâ¤Á¶Ö§ËÁÍá»Å§ËÃ×Íä´ÃàÇÍÃäÁ¤ÇÃà¡Ô¹ 10 àÁµÃ
Warning
-Please ensure that the led lamp is connected to the driver correctly.
Wrong polarity connection cause a damage to the led lamp and driver.
â»Ã´ÃÐÇѧ¡ÒõÍÊÒÂä¿ÊÅѺ¢ÑéÇ +ºÇ¡ -ź ¨Ò¡ä´ÃàÇÍÃÁÒà¢Ò·ÕèËÅÍ´ LED ËÒ¡µÍÊÅѺ¢ÑéÇ
¨Ð·íÒãËä´ÃàÇÍÃáÅÐËÅÍ´ LED à¡Ô´¤ÇÒÁàÊÕÂËÒÂ
Please note the ground level.
¢ͤÇÃÃÐÇѧ: ¼ÔÇ˹ҢͧµÑÇâ¤Á¡Ñº
¼ÔǾ×鹤ÇÃÍÂÙã¹ÃйҺà´ÕÂǡѹ
4For class I
lll
For class III
5
5.1
5.2
5.3
5.4
Torque/áçºÔ´ : 1.0 Nm.
Torque/áçºÔ´ : 1.0 Nm.
Installation complete
¡ÒõԴµÑé§àÊÃç¨ÊÁºÙó
6
4.1 Use the rubber seal according to the size of the cable
àÅ×Í¡ãªÅÙ¡ÂÒ§à¤àºÔÅá¡Åç¹´ µÒÁ¢¹Ò´¢Í§ÊÒÂä¿
Cable size Dia Ø7-9 mm.
¢¹Ò´ÊÒÂä¿
12
Rubber seal size
ÅÙ¡ÂÒ§à¤àºÔÅá¡Åç¹´·Õèãª
Cable size Dia Ø10-12 mm.
¢¹Ò´ÊÒÂä¿
Cable size :
¢¹Ò´ÊÒÂä¿
9
IP68 water tight connecting device.
Available Separately
µÑǵÍÊÒÂä¿»ͧ¡Ñ¹¹éíÒ ¨íÒ˹ÒÂᡵÒ§ËÒ¡
Ordering Code/ÃËÑÊÊÑè§«×éÍ: 9-0903-00
1
3
2
4
10
Make sure that
cable glands are
fastened.
µͧ¢Ñ¹Ê¡ÃÙãËá¹¹·Ø¡µÑÇ
Make sure that the rubber seal is
correctly in place.
ÃÐÇѧÅÙ¡ÂÒ§ËÅØ´ÍÍ¡¨Ò¡ªØ´à¤àºÔéÅá¡Ã¹
5
L = BROWN (ÊÕ¹éíÒµÒÅ)
=Green and yellow (ÊÕà¢ÕÂǡѺÊÕàËÅ×ͧ)
N = Blue (ÊÕ¿Ò)
7
6
8
9
FR-DM-17 REV.03 EFF 15/09/17Last Revised On : 26/10/2020 REV.07
3/5
Cable pipe
Water drainage pipe
·͹éíÒ·Ôé§
General installation guide ( highly recommended)
¢Íá¹Ð¹íÒ㹡ÒõԴµÑé§
20-30 cm.
Place the gravel 20-30 cm.depth underneath the casing for water
drainage (Pic-1).Then do the testing by filling water into the casing
and let it drain.The water should be drained out by 30 minutes.
If not,the additional drainage pipe or other system must be applied
(Pic-2)
¤ÇÃÇÒ§¡͹¡ÃÇ´ãµ¡Åͧ½§¾×é¹·ÕèÃÐÂÐÅÖ¡»ÃÐÁÒ³ 20-30 «Á. à¾×èͪÇÂÃкÒÂ
¹éíÒ·Õè·ÇÁ¢Ñ§µÑÇâ¤Áä¿ ÊÒÁÒö·´Êͺ¡ÒÃÃкÒ¹éíÒâ´Âà·¹éíÒãÊ¡ÅͧãËàµçÁ
¹éíҨеͧÃкÒÂÍÍ¡ËÁ´ÀÒÂã¹àÇÅÒ 30¹Ò·Õ ËÒ¡äÁà»¹µÒÁ¹Ñ鹤ÇÃÁÕ¡ÒõÍ
·ÍÃкÒ¹éíÒà¾ÔèÁàµÔÁ
Pic-1
ÃÙ»-1
Pic-2
ÃÙ»-2
Installation should not be done under high humidity environment i.e.
rainy day or after the rain,foggy weather....ect.
äÁ¤ÇõԴµÑé§â¤Áä¿ã¹ªǧ·ÕèÁÕ¤ÇÒÁª×é¹ÊÙ§àª¹ Çѹ·Õè½¹µ¡µÅÍ´ËÃ×͵ԴµÑé§ËÅѧ
½¹ËÂØ´µ¡à¾ÃÒШзíÒãË¤ÇÒÁª×é¹¶Ù¡¢Ñ§äÇã¹µÑÇâ¤Áä¿ËÅѧ¨Ò¡¹Ñ鹨Ðà¡Ô´¡ÒÃ
¤Çºá¹¹à»¹ÅÐÍͧËÃ×ÍË´¹éíÒà¡ÒеԴºÃÔàdzãµ¡ÃШ¡ÀÒÂã¹µÑÇâ¤Áä¿
Do not let the exposed part of the fittings be covered by the soil,dried weed or
foliage as well as corrosive or aggressive substancechemicals.
ÍÂÒ»ÅÍÂãËÁÕÊÔè§Ê¡»Ã¡àª¹ àÈÉ´Ô¹ ãºäÁ ËÃ×Í ËÒáË§ÃÇÁ¶Ö§à¤ÁÕ·Õèà»¹ÊÒà -¡Ñ´¡Ã͹ÁÒ»¡
¤ÅØÁÊÐÊÁºÃÔàdz˹Ò¾×é¹¼ÔǵÑÇâ¤Áä¿
Do not throw or drop any hard objects onto the top of fittings.
ÍÂÒãËÇѵ¶Ø·Õèà»¹¢Í§á¢ç§ËÅ¹ ËÃ×͵¡¡ÃÐá·¡ãÊºÃÔàdz˹Ò¾×é¹¼ÔǢͧµÑÇâ¤Á
The surface temperature of the fitting can be very high after continuation in
service.
àÁ×èÍà»´ä¿·Ôé§äÇã¹ÃÐÂÐàÇÅÒ˹Ö觨Ðà¡Ô´¤ÇÒÁÃ͹ÊÐÊÁºÃÔàdz´Ò¹º¹¢Í§µÑÇâ¤Á俤ÇÃÃÐÁÑ´ÃÐÇѧ
¡ÒÃÊÑÁ¼Ñʶ١ºÃÔàdz´Ñ§¡ÅÒÇ
Proper use of this fitting must be observed.
¤ÇþԨÒóҤÇÒÁàËÁÒÐÊÁ¢Í§¾×é¹·ÕèËÃ×͵íÒá˹§·Õè¨ÐµÔ´µÑé§µÑÇâ¤Áä¿ µÑÇÍÂÒ§ àª¹ ÁÕ
¹éíҢѧà»¹»ÃШíÒ㹺ÃÔàdz¹Ñé¹ËÃ×ÍäÁ? , Çѵ¶ØµÒ§æ àª¹ ´Ô¹,àÈÉãºäÁãºËÒÁÕâÍ¡ÒÈ·Õè¨ÐÁÒ»¡
¤ÅØÁÊÐÊÁº¹Ë¹Òâ¤Áà»¹»ÃÔÁÒ³ÁÒ¡ËÃ×ÍäÁ ? áÅÐäÁ¤ÇõԴµÑé§ã¹ºÃÔàdz·ÕèÍÒ¨ÁÕâÍ¡Òȶ١ÊÑÁ¼ÑÊ
â´Â¤¹ â´Â੾ÒÐà´ç¡àÅç¡ËÃ×ÍÊѵÇàÅÕé§
FR-DM-17 REV.03 EFF 15/09/17Last Revised On : 26/10/2020 REV.07
4/5
YES/¶Ù¡µͧ NO/äÁ¶Ù¡µͧ NO/äÁ¶Ù¡µͧ
1. 1.
2.
3.
4.
5.
2.
Remark :
ËÁÒÂà˵Ø
Installation should be carried out by a qualified
electrician in accordance with appropriate national
wiring regulation.
¡ÒõԴµÑé§â¤Áä¿¿ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´ÂªÒ§ä¿¿Ò ·ÕèÁÕ
¤ÇÒÁÃÙáÅФÇÒÁªíÒ¹Ò 㹡ÒõԴµÑé§ÍØ»¡Ã³ä¿¿Ò â´Â੾ÒеÒÁ
ÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿Ò
Disconnect the power before changing the lamp.
»´ÊÇÔ·ªä¿·Ø¡¤ÃÑé§·Õèà»ÅÕè¹ËÅÍ´ä¿
For Class1 luminaire, the installation must be
completed with earthing.
ÊíÒËÃѺâ¤Áä¿·ÕèÁÕ¡Òûͧ¡Ñ¹ä¿¿ÒÃÑèÇÃдѺ1 ¡ÒõԴµÑé§µͧµÍÊÒÂ
´Ô¹µÒÁÁÒµÃฐÒ¹¤ÇÒÁ»ÅÍ´ÀÑ´ÇÂ
Do not exceed the maximum wattage.
ËÒÁãªËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµà¡Ô¹¡ÇÒ·ÕèÃÐºØ ËÃ×ÍãªËÅÍ´¼Ô´»ÃÐàÀ·
Don't touch LED while maintaining or cleaning.
ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃØ§ÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´
Warning :
¢ͤÇÃÃÐÇѧ
The manufacturer will not be liable or held responsible
for any incorrect installation, misuse or improper use
and unauthorised modification to the fittings. Failure
to comply with mentioned warning may cause serious
damage or serious injury to persons, animals or
objects. If any modification is required please consult
your dealer for the details.
·Ò§¼Ù¼ÅÔµäÁÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡¡ÒÃ
µÔ´µÑé§äÁ¶Ù¡ÇÔ¸Õ, ãª§Ò¹¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Áã¹·Ø¡¡Ã³Õ
«Öè§ ÊÔè§¼Ô´»¡µÔàËÅÒ¹Õé ÍÒ¨·íÒãËà¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊѵÇ ÊÔ觢ͧ
ËÒ¡ÁÕ¢ÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµͧ¡ÒûÃѺáµ§µÑÇâ¤Á ãËàËÁÒÐÊÁ¡Ñº
¡ÒÃãª§Ò¹ ¡ÃسҵԴµ͵ÑÇá·¹¨íÒ˹ÒÂËÃ×ͼÙ¼ÅÔµ
Where damage has occured to the fittings, please
make the replacement with standard parts before use.
㹡óշÕèÁÕªÔé¹Êǹ»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒÂ¡ÃØ³Òà»ÅÕ蹪Ôé¹
ÊǹãËÁ¡͹¡ÒÃãª§Ò¹·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑÂ
Walk over fittings.Max 1000 Kg pressure load.
â¤Ã§ÊÃÒ§¢Í§â¤Á俪¹Ô´¹ÕéÊÒÁÒöà´Ô¹àËÂÕºº¹Ë¹Òâ¤Áä´ áÅÐÃѺáç¡´·Ñºä´ 1,000 ¡¡.
FR-DM-17 REV.03 EFF 15/09/17Last Revised On : 26/10/2020 REV.07
5/5
Cable Size/¢¹Ò´ÊÒÂä¿ : 3x1.00 mm. Ø7-12 mm.
2
Cable Size/¢¹Ò´ÊÒÂä¿ : 2x1.00 mm. Ø6-13 mm.
2
NO Do not touch the LED because it may shorten the life time or the LED can be
breaking down.
ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED â´Âà´ç´¢Ò´ à¾ÃÒШзíÒãËËÅÍ´àÊ×èÍÁÊÀÒ¾
Minimum distance to lighted surface.
ÃÐÂÐËÒ§¢Ñé¹µèíÒ ¨Ò¡Ë¹Òâ¤Á¶Ö§¾×é¹¼ÔÇ·Õè¶Ù¡ÊͧÊÇÒ§
0.5 m
Any damaged safety glass cover must be replaced only with the original
spare part.
àÁ×èÍ¡ÃШ¡à¡Ô´¤ÇÒÁàÊÕÂËÒ à¾×èͤÇÒÁ»ÅÍ´ÀѤÇÃÊÑè§ÍÐäËÅá·¨Ò¡¼Ù¼ÅÔµà·Ò¹Ñé¹
Environmental protection: Waste electrical products should not be disposed of
with household waste. please recycle where facilities exist.check with your local
authority or retailer for recycling advice.
ËÒÁ·Ôé§¼ÅÔµÀѳ±¹ÕéÃÇÁ¡Ñº¢ÂÐ㹤ÃÑÇàÃ×͹ª¹Ô´Í×è¹æ àÁ×èÍÊÔé¹ÊØ´ÍÒÂØ¡ÒÃãª§Ò¹ â»Ã´á¡¼ÅÔµÀѳ±
ÍÍ¡¨Ò¡¢Í§àÊÕ»ÃÐàÀ·Í×è¹æ áÅÐÃÕä«à¤ÔÅÍÂÒ§àËÁÒÐÊÁ à¾×èÍÊ§àÊÃÔÁ¡ÒùíÒ·ÃѾÂҡáÅѺÁÒãª«éíÒ «Öè§
¨ÐªÇ»ͧ¡Ñ¹ÍѹµÃÒµÍÊÔè§áÇ´ÅÍÁËÃ×ÍÊØ¢ÀÒ¾¢Í§Á¹ØÉÂ·Õèà¡Ô´¨Ò¡¡Ò÷Ôé§¢ÂÐâ´ÂäÁÁÕ¡ÒäǺ¤ØÁ
For class I
For class III lll
NO Not using chemical compounds and aggressive agents such as , weed repellents
fertilizers , acid solvent and contaminated irrigation water near the Luminaires.
ËÒÁãªÊÒÃà¤ÁÕàª¹ »ØÂ, ÂÒ¡íҨѴÈѵÃپת, »Ù¹¢ÒÇ, ÊÒÃÅÐÅÒ·Õèà»¹¡Ã´ áÅйéíÒ»¹à»͹ÊÒÃà¤ÁÕ
ºÃÔàdz·ÕèµÔ´µÑé§â¤Áä¿
FR-DM-17 REV.03 EFF 15/09/17Last Revised On : 26/10/2020 REV.07

This manual suits for next models

1

Other Unilamp Outdoor Light manuals

Unilamp SIRIUS 300 User manual

Unilamp

Unilamp SIRIUS 300 User manual

Unilamp XEON Cross User manual

Unilamp

Unilamp XEON Cross User manual

Unilamp Maxi CORE OD-4102 User manual

Unilamp

Unilamp Maxi CORE OD-4102 User manual

Unilamp Mini PETINA 1 User manual

Unilamp

Unilamp Mini PETINA 1 User manual

Unilamp Mega SONIC Indirect Wall Ligh User manual

Unilamp

Unilamp Mega SONIC Indirect Wall Ligh User manual

Unilamp MEGA SONIC-ARM User manual

Unilamp

Unilamp MEGA SONIC-ARM User manual

Unilamp PLUMO LED SLIM RAMP User manual

Unilamp

Unilamp PLUMO LED SLIM RAMP User manual

Unilamp XEON Cross - Wall Light User manual

Unilamp

Unilamp XEON Cross - Wall Light User manual

Unilamp PILLAR/1 User manual

Unilamp

Unilamp PILLAR/1 User manual

Unilamp Medium ALPHA Square User manual

Unilamp

Unilamp Medium ALPHA Square User manual

Unilamp POM Opal User manual

Unilamp

Unilamp POM Opal User manual

Unilamp Mini CHARISMA1 Square-Bollard User manual

Unilamp

Unilamp Mini CHARISMA1 Square-Bollard User manual

Unilamp KUBIK OD-5951 User manual

Unilamp

Unilamp KUBIK OD-5951 User manual

Unilamp Mini Quark Round User manual

Unilamp

Unilamp Mini Quark Round User manual

Unilamp 9007-4-2-361-91 User manual

Unilamp

Unilamp 9007-4-2-361-91 User manual

Unilamp CASA User manual

Unilamp

Unilamp CASA User manual

Unilamp ZOUK2 User manual

Unilamp

Unilamp ZOUK2 User manual

Unilamp CONE 3 User manual

Unilamp

Unilamp CONE 3 User manual

Unilamp SABER/1 User manual

Unilamp

Unilamp SABER/1 User manual

Unilamp HEXAHEDRON User manual

Unilamp

Unilamp HEXAHEDRON User manual

Unilamp BUZZ1 User manual

Unilamp

Unilamp BUZZ1 User manual

Unilamp PLUTO Slim Ramp User manual

Unilamp

Unilamp PLUTO Slim Ramp User manual

Unilamp ATOM - CC Spotlight User manual

Unilamp

Unilamp ATOM - CC Spotlight User manual

Unilamp SIROCCO User manual

Unilamp

Unilamp SIROCCO User manual

Popular Outdoor Light manuals by other brands

Lighting Technologies LOTOS LED manual

Lighting Technologies

Lighting Technologies LOTOS LED manual

ABBA TSP300 installation guide

ABBA

ABBA TSP300 installation guide

Safavieh TBL4386A Assembly instructions

Safavieh

Safavieh TBL4386A Assembly instructions

Eaton HALO FT18VCW instruction manual

Eaton

Eaton HALO FT18VCW instruction manual

BEGA 77 089 Installation and technical information

BEGA

BEGA 77 089 Installation and technical information

enLighten Zorro Unplugged SSL06-4K-TIII-GRY installation instructions

enLighten

enLighten Zorro Unplugged SSL06-4K-TIII-GRY installation instructions

Vaxcel T0246 Assembly and installation instructions

Vaxcel

Vaxcel T0246 Assembly and installation instructions

Quoizel DE8407K Assembly instruction sheet

Quoizel

Quoizel DE8407K Assembly instruction sheet

BEGA Gobo 84 987 Instructions for use

BEGA

BEGA Gobo 84 987 Instructions for use

iGuzzini MAXYWOODY Instructions for installing

iGuzzini

iGuzzini MAXYWOODY Instructions for installing

SLV DASAR 233500 operating manual

SLV

SLV DASAR 233500 operating manual

SUN AMEX MOOVY Instructions for use

SUN AMEX

SUN AMEX MOOVY Instructions for use

Anslut 010547 operating instructions

Anslut

Anslut 010547 operating instructions

Saxby Lighting Severus Outdoor Wall EL-40103 Instruction

Saxby Lighting

Saxby Lighting Severus Outdoor Wall EL-40103 Instruction

bover Tanit M/29/R Assembly instructions

bover

bover Tanit M/29/R Assembly instructions

GLUCKSTEINHOME GLUCKSTEINELEMENTS 39458-HBCLED Use and care guide

GLUCKSTEINHOME

GLUCKSTEINHOME GLUCKSTEINELEMENTS 39458-HBCLED Use and care guide

LIGMAN AA-20166 Installation and service manual

LIGMAN

LIGMAN AA-20166 Installation and service manual

RH THADDEUS Assembly & installation

RH

RH THADDEUS Assembly & installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.