UNIONCOMMUNITY MCP-040 User manual

Doc. Ver. : V2.0
2014.10.23
R&D Center
Union Community Co., Ltd.
Installation & Wiring Guide
Installation guide for MCP-040 V2.0 with
VSR20D & EB030
1. Power Connector connection
Installation for MCP-040 V2.0
Backup Battery
Interface
BAT(-)
BAT(+)
15V GND
DC 15V 6A
Power Adapter
PWR+ PWR-
12V G12V G
12V G
5V G
GND
15V
DC 15V OUT
DC 5V OUT
GND
5V
GND
15V
DC 15V OUT
GND15V
DC 15V OUT
2. Main Board Feature
Switch Setting I[ Lock Type Selection ]
JP201 : NO [ Normal Open Relay Contact ]
NC [ Normal Close Relay Contact ]
JP202 : NO [ Normal Open Relay Contact ]
NC [ Normal Close Relay Contact ]
JP203 : NO [ Normal Open Relay Contact ]
NC [ Normal Close Relay Contact ]
JP204 : NO [ Normal Open Relay Contact ]
NC [ Normal Close Relay Contact ]
Switch Setting III [ RS485 T_Resistor Selection ]
JP151 : ON [ 120ohm termination resistor ]
OFF [ Open the termination resistor ]
JP152 : ON [ 120ohm termination resistor ]
OFF [ Open the termination resistor ]
JP201~JP204
JP205~JP208
Lock Type Switch
JP151/JP152 RS485 Termination
Resistor Select Switch
SW301
Battery Power On Switch
Installation for MCP-040 V2.0
Switch Setting II [ Lock Type Selection ]
JP205 : Lock Power Contact / Lock No Power Contact
JP206 : Lock Power Contact / Lock No Power Contact
JP207 : Lock Power Contact / Lock No Power Contact
JP208 : Lock Power Contact / Lock No Power Contact
ZONE2/ZONE6
ZONE3/ZONE7
RDRA+
15V IN
GND
COM
NO/NC LOCK#1
IN1
IN3
IN4
IN2
GND
GND
GND
GND
ZONE1/ZONE5
ZONE4/ZONE8
GND
Ethernet
15V OUT 5V OUT
EXPA+
OUT1
D01
D11
3. Connection of Wires to terminal blocks
D01 D11 OUT1 OUT2
D02 D12 OUT3 OUT4
D03 D13 OUT5 OUT6
D04 D14 OUT7 OUT8
PWR+ PWR-
12V G12V G
12V G
5V G
NO/
NC COM NO/
NC COM NO/
NC COM NO/
NC COM
Z1/
Z5 GZ2/
Z6
Z3/
Z7 GZ4/
Z8 G G RDRA
+
BELL+RDRB
-
EXPA
+
EXPB
-
BELL-
IN1 G IN2 IN3 G IN4
15V OUT 15V OUT
GND
GND
GND
BELL+
BELL-
EXPB-
RDRB-
GND
GND
COM
NO/NC LOCK#2
COM
NO/NC LOCK#3
COM
NO/NC LOCK#4
D03
D13
D02
D12
D04
D14
OUT2 OUT3
OUT4
OUT5
OUT6 OUT7
OUT8
Installation for MCP-040 V2.0
1:RED : +12V
2:Black : GND
3:Green : 485A+
4:Blue : 485B-
RS-485 Termination Resistor Select S/W :
SW151
VSR20D
VSR20D
VSR20D
One MCP-040 can be connected with VSR20D
readers max 8ea in parallel
4. Connecting VSR20D via RS485
EXPB-
J253
RDRA+
EXPA+
BELL+
RDRB-
BELL-
12V
GND
J252 or J254
RDR JP151
ON OFF
EXP JP152
ON OFF
Installation for MCP-040 V2.0
Each VSR20D reader should be set the different RS485 ID with DIP switch when they are connected to MCP in parallel
5. How to give the different 485 ID to each VSR20D
Installation for MCP-040 V2.0
485 ID = 0
485 ID = 7
485 ID = 6 485 ID = 5
485 ID = 4 485 ID = 2 485 ID = 1
485 ID = 3
: Lock (+)
: Lock (-)
: Door Monitor (NO)
: Ground (Door Status
Com)
J251
Red
Black
Green
Gray
LOCK4
LOCK3
LOCK2
LOCK1
COM
NO/NC
COM
NO/NC
COM
NO/NC
COM
NO/NC
GND
GND
Z4/Z8
GND
Z3/Z7
Z2/Z6
GND
Z1/Z2
6. Connecting Dead-Bolt Type Door Lock (Fail Safe)
J251
Installation for MCP-040 V2.0
Lock Type Select S/W
Lock2
NO
NC
JP202
PWR
nPWR
JP206
Lock3
NO
NC
JP203
PWR
nPWR
JP207
Lock4
NO
NC
JP204
PWR
nPWR
JP208
Lock1
NO
NC
JP201
PWR
nPWR
JP205
7. How to do pairing each lock to each reader
Installation for MCP-040 V2.0
Do pairing between 4 locks to 12 readers on MCP-040 from the Terminal Setup Option on UNIS
1> Select the reader among the readers are connected to MCP-040
2> Select the lock number among the locks are connected to MCP-040
3> Click the button “Save”
4> Click the button “Apply”
And then the paired lock will be opened whenever the user is authenticated by the paired reader.
8. How to connect four EB030 units to MCP-040
Installation for MCP-040 V2.0
EB-030
Red : 12V
Black : GND
Green : NO
Brown : COM
J253
IN4
GND
IN3
IN2
GND
IN1
12V
GND
J252 or J254
9. How to do pairing each EXIT button to each lock
Installation for MCP-040 V2.0
Do pairing between 4 EXIT buttons to 4 locks on MCP-040 from the Terminal Setup Option on UNIS
1> Select the tab “In/Output”
2> Select the Exit button number among the buttons are connected to MCP-040
2> Insert the lock number from 1 to 4 which you want to pairing
3> Click the button “Save”
4> Click the button “Apply”

Popular Control Unit manuals by other brands

Asahi/America 56 manual

Asahi/America

Asahi/America 56 manual

Johnson Controls S1-TTSCC01 Technical guide

Johnson Controls

Johnson Controls S1-TTSCC01 Technical guide

Wegmatt dAISy FeatherWing manual

Wegmatt

Wegmatt dAISy FeatherWing manual

GE Ziton ZP3-ECU Maintenance manual

GE

GE Ziton ZP3-ECU Maintenance manual

BASF EXACTUS IFX-21 user guide

BASF

BASF EXACTUS IFX-21 user guide

NXP Semiconductors i.MX8 QM Developer's guide

NXP Semiconductors

NXP Semiconductors i.MX8 QM Developer's guide

CommScope CMOD installation instructions

CommScope

CommScope CMOD installation instructions

Cloud BT-IFW installation guide

Cloud

Cloud BT-IFW installation guide

Campbell TEMP 120 product manual

Campbell

Campbell TEMP 120 product manual

GOSUNCN ME3630 mini-PCIE Development guide

GOSUNCN

GOSUNCN ME3630 mini-PCIE Development guide

Emerson unidrive m Installation and operating manual

Emerson

Emerson unidrive m Installation and operating manual

smart home SH-U6 manual

smart home

smart home SH-U6 manual

Lippert Ground Control 3.0 LCD manual

Lippert

Lippert Ground Control 3.0 LCD manual

Texas Instruments TRF7970A BoosterPack user guide

Texas Instruments

Texas Instruments TRF7970A BoosterPack user guide

Pilz PIT m3.3p operating manual

Pilz

Pilz PIT m3.3p operating manual

Purelogic PLD330 instruction manual

Purelogic

Purelogic PLD330 instruction manual

SCIENCE LCTA quick start guide

SCIENCE

SCIENCE LCTA quick start guide

Harvia sentiotec Pro-C3 Instructions for installation and use

Harvia

Harvia sentiotec Pro-C3 Instructions for installation and use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.