IMP12-16
www.ueonline.com
4
Option M421, M423 & M513 Junction Boxes
Option M430 Adjustment Cover Lock
Surface Mounting Bracket (Kit P/N 62169-13)
UNITED ELECTRIC
CONTROLS
180 Dexter Avenue, P.O. Box 9143
Watertown, MA 02471-9143 USA
Telephone: 617 926-1000 Fax: 617 926-2568
http://www.ueonline.com
RECOMMENDED PRACTICES AND WARNINGS
United Electric Controls Company recommends careful consideration of the
following factors when specifying and installing UE pressure and temperature
units. Before installing a unit, the Installation and Maintenance instructions
provided with unit must be read and understood.
• To avoid damaging unit, proof pressure and maximum temperature limits
stated in literature and on nameplates must never be exceeded, even by
surges in the system. Operation of the unit up to maximum temperature
is acceptable on a limited basis (i.e., start-up, testing) but continuous
operation must be restricted to the designated adjustable range. Excessive
cycling at maximum temperature limits could reduce sensor life.
• A back-up unit is necessary for applications where damage to a primary
unit could endanger life, limb or property. A high or low limit switch is
necessary f or applications where a dangerous runaway condition could
result.
• The adjustable range must be selected so that incorrect, inadvertent or
malicious setting at any range point cannot result in an unsafe system
condition.
• Install unit where shock, vibration and ambient temperature fluctuations will
not damage unit or affect operation. Orient unit so that moisture does not
enter the enclosure via the electrical connection. When appropriate, this
entry point should be sealed to prevent moisture entry.
• Unit must not be altered or modified after shipment. Consult UE if
modification is necessary.
• Monitor operation to observe warning signs of possible damage to unit,
such as drift in set point or a faulty display. Check unit immediately.
• Preventative maintenance and periodic testing is necessary for critical
applications where damage could endanger property or personnel.
• For all applications, a factory set unit should be tested before use.
• Electrical ratings stated in literature and on nameplate must not be
exceeded. Overload on a switch can cause damage, even on the first cycle.
Wire unit according to local and national electrical codes, using wire size
recommended in installation sheet.
• Do not mount unit in ambient temp. exceeding published limits.
LIMITED WARRANTY
Seller warrants that the product hereby purchased is, upon delivery, free
from defects in material and workmanship and that any such product which
is found to be defective in such workmanship or material will be repaired or
replaced by Seller (Ex-works, Factory, Watertown, Massachusetts. INCOTERMS);
provided, however, that this warranty applies only to equipment found to
be so defective within a period of 36 months from the date of manufacture
by the Seller. Seller shall not be obligated under this warranty for alleged
defects which examination discloses are due to tampering, misuse, neglect,
improper storage, and in any case where products are disassembled by
anyone other than authorized Seller’s representatives. EXCEPT FOR THE
LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE, SELLER
DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT,
INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR
ANY PARTICULAR PURPOSE.
LIMITATION OF SELLER’S LIABILITY
Seller’s liability to Buyer for any loss or claim, including liability incurred in
connection with (i) breach of any warranty whatsoever, expressed or implied,
(ii) a breach of contract, (iii) a negligent act or acts (or negligent failure to act)
committed by Seller, or (iv) an act for which strict liability will be inputted to
seller, is limited to the “limited warranty” of repair and/or replacement as so
stated in our warranty of product. In no event shall the Seller be liable for
any special, indirect, consequential or other damages of a like general nature,
including, without limitation, loss of profits or production, or loss or expenses
of any nature incurred by the buyer or any third party.
UE specifications subject to change without notice.
CP04135000
M421 - EAC only
M423 - ATEX or IEC only
(Not cULus approved)
Cover not shown
M513 - cULus only; does not
meet Enclosure Type 4X
Cover not shown
1/32"
MIN. SPACE
Option M430:
Cover Lock
Adjustment
Cover
Note: A 1/32” min. space must
be maintained between the
bottom of the cover lock and
the top of the adjustment
cover to ensure proper dual
seal annunciation
and venting .
Figure 5
Mounting Bracket
Adjustment
Cover
Figure 6
Shown with Optional Cover
Lock (M430)
1/2” NPT (Female)
Ports, 2 PLCS
External
Ground
Screw
Internal Ground Screw
No Access
Sealed Port
1/2” NPT (Male)
Conduit Plug 10mm
HEX Drive
4” [102mm]
4”
[102mm]